Guangdong Xindun Power Technology Co.,Ltd |
|
Feature
Solar module:solar battery module(also called photovoltaic battery
module)in series or in parallel according to the system
requirements,the solar energy will change into electrical energy in
the light of the sun and then output,it is the core component of
solar photovoltaic system.
Controller: solar power controller is an important part of the
solar power system, System of charging and discharging and load
work automatically by its intelligent control and protection. Its
performance directly affects the reliability of the system.
Especially the battery life, overcharge or over discharge will be
cause damage and even lethal damage for the battery.
Inverter: in solar photovoltaic power supply system, if it has the
AC load, it is necessary to use the devices of the inverter. The
direct current generated by solar modules or the battery release of
DC into AC for load.
Battery:Stored up the electricity produced by the solar cell module
produce,When illumination is insufficient or night or load demand
is greater than the power produced by the solar cell module.Stored
energy will be released in order to meet the load demand of
energy,It is the solar energy photovoltaic system energy storage
unit.Currently solar pv system commonly used is lead acid
battery,For higher requirements of the system,Usually adopt deep
discharge vrla battery ,deep discharge suction fluid type lead-acid
battery,etc
Technical specification
Specifications: | ||||||
Model XD- | TNY50112-10 | TNY70112-50 | TNY10224-50 | TNY20248-40 | TNY50296-50 | |
Solar Energy Module | Type | Monocrystalline silicon A level | ||||
Power | 100W | 500W | 1100W | 1800W | 4400W | |
Daily Power generation | 0.5KWH | 2.5KWH | 5.5KWH | 9KWH | 22KWH | |
(Sunshine according to 5H) | ||||||
Size(mm) | 1160×660×35×1 | 1250*660*35*4 | 1360*900*40*6 | 1620*990*40*8 | 1955*990*45*16 | |
PV Controller | Control mode | Direct charge/PWM/MPPT | ||||
Charge current | 10A | 50A | 50A | 40A | 50A | |
Rated charging voltage | 12VDC | 12VDC | 24VDC | 48VDC | 96VDC | |
Compulsive charging voltage | 14.8V | 29.6V | 59.2V | 118.4V | ||
Balanced charging voltage | 14.4V | 28.8V | 57.6V | 115.2V | ||
Floating charging voltage | 13.8V | 27.6V | 55.2V | 110.4V | ||
Recovery charging voltage | 13.3 | 26.6V | 53.2V | 106.4V | ||
Battery overvoltage protection/recovery | 16.5V/15V | 33V/30V | 66V/60V | 132V/120V | ||
Protection function | Reverse connection, short circuit, overcharge, anti charge protection | |||||
Display | LED | |||||
PV Inverter | Rated Capacity | 500W | 700W | 1000W | 2000W | 5000W |
DC voltage | 12V | 24V | 48V | 96V | ||
Undervoltage protection | 10.5V | 21V | 42V | 84V | ||
Inverter structure | Low frequency structure | |||||
Mains input | 75VAC-125VAC or 145VAC-275VAC | |||||
Inverter output | 110VAC+/-2% or 220VAC+/-2% | |||||
Mains input charging current | 10A | |||||
Working way | Mains priority/solar power priority (optional) | |||||
Conversion time | ≤4ms | |||||
Overload capacity | Overload 110% 30 seconds the machine automatically shut down; overload shutdown 120% 2 seconds; mains mode overload do not shutdown | |||||
Conversion efficiency | ≥80% | |||||
Output waveform | Pure sine wave | |||||
Work environment | Temperature0-40°C,Humidity10-90% | |||||
Cooling mode | Forced air cooling | |||||
Protection function | Mains over / under-voltage, direct current is too high / undervoltage, the inverter output short circuit | |||||
Display | LCD | |||||
Output waveform distortion | ≤±0.3% | |||||
Input and output frequency | The same with power system | |||||
Battery | Battery Type | Deep cycle maintenance-free lead-acid battery | ||||
Battery capacity | 100AH/12V×1 | 200AH/12V×1 | 100AH/12V×2 | 200AH/12V×4 | 100AH/12V×8 | |
Discharge time(full Load calculation) | 1.3H | 1.8H | 1.3H | 2.8H | 1.1H | |
Machine specifications | Size(mm) | 465×245×465 | 580×280×470 | 580×300×610 | 600×540×940 | |
Weight | 48KG | 81KG | 7KG | 302KG | 332KG | |
Remarks | Specification for reference.Subject to change without prior notice |