Shenzhen Maixiang Technology Co.,Ltd |
|
Dimension | 330*232*972mm |
Power Supply | AC110±10% / AC220±10% |
Frequency | 50HZ / 60HZ |
Working Temperature | -40°to 85° |
Related Humidity | ≤90% |
Remote Control Distance | >30m |
Arm Speed | 0.6s,0.8s,1s, 3s, 6s,8s |
Description/Speed | 0.6s,0.8s | 1s,1.8s | 3s | 6s | 8s |
Max Straight Arm | 2.5m | 3m | 4.5m | 6m | 8m |
Arm Swing Out | Yes | Yes | Yes | Yes | Yes |
Octagon Arm | Yes | Yes | Yes | Yes | Yes |
Tetragon Arm | Yes | Yes | Yes | Yes | Yes |
Red Rubber Arm | Yes | Yes | Yes | Yes | Yes |
Feature:
Advance Function:
*Manual release
*Machine core with compression spring
*Aluminum alloy motor, precision and good at thermal radiating
*Intelligent overheating protection system, solving the problem of heat-protection
*Double safety limit switches (photoelectric limit switch/mechanical limit switch)
*Reversing on obstacle
*Auto-closing
*Special blancing structure design makes the barrier boom has the feature of slow-staring,
fast-running, slow stopping
*90 degree running which excludes the accident caused by 360 degrees running
*Special low-speed motor with aluminum casing, one-piece gear box design, low noise, fast heat-dissipation
Communication with customers
1. Motor works but there is no reaction on the arm.
a. Please check whether the clutch device is locked or not.
2. There is too much vibrant when the boom is rising or falling.
a. Please check whether the shock absorption rubber is broken or
not, if yes, change a new one.
b. Please check whether the balance spring is overused and
distorted. If yes, change a new one.
b. Please check whether the balance spring is overused and
distorted.If yes, change a new one, or spin
bottom adjust nut.
3. The boom could not rise up or fall down to the end.
a. When change a long boom to a short one, please readjust it.
b. The sensor does not plug well, please chek it.
c. The " Speed adjust switch" is wrong adjust, please readjust it.
4. The distance of the remote control decreases.
a. Check whether the charge capacity of the remote controller is
enough or not.
5. There is no reaction when pressing the remote controller
buttons.
a, Please check whether the power is supplied to the barrier gate
or not.
b. Please check whether the fuse is burnt out or not.
c. Please check whether the code both in the remote controller and
the control board are accordant or not.
6 There is no reaction on the motor when the user changes a control
board.
a. Please check the capacitance is correctly fixed or not.
b. Please check the sensor is right inserted or not.
Optional Boom
A: Booms for avoiding striking(medium-sized octagonal boom, round
foam boom,elliptic boom)
B:180°articulated boom(Max 4M)
C:90° articulated boom(Max 4M)
D:2 fences boom(Max 5M)
E:3 fences boom(Max 4M)
Boom with LED lights and light colors changeable.
Light flashing pattern, speed and colors controlled by a remote
control.