Home Companies Advanced Instruments Co.,Ltd

CT VT Testing Equipment Analzer for Current and Voltage Transformer Test

Advanced Instruments Co.,Ltd
Active Member

Contact Us

[China] country

Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China 

Contact name:Sandy

Inquir Now

Advanced Instruments Co.,Ltd

CT VT Testing Equipment Analzer for Current and Voltage Transformer Test

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

 

CT VT Testing Equipment Analyzer

 

Testing for current transformer equipment:

1 Excitation curve and parameters test
2 Turns ratio test
3 Ratio and phase error test
4 Polarity mark check
5 Winding resistance measurement
6 Secondary loop burden measurement
7 Error line curve test for protection CT
8 Transient CT parameters test
9 CT nameplate guess
10 Saturation hysteresis loop curve measurement

 

Testing for Voltage Transformer equipment

1 Turns ratio test
2 Ratio error and phase angle error test
3 Polarity test
4 Secondary burden test
5 Winding resistance test

 

Applications of CT/ VT Testing Equipment:

1 CT nameplate check
2 CT parameters check in work burden
3 CT transient parameters analysis
4 CT ratio and phase error calibration
5 VT routine test

 

Specifications:

Item NameCT and VT Testing Equipment
Test standardsIEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supplyAC220V±10%, 50/60Hz±10%
Voltage output0.1~180V (AC)
Current output0.001~5A(RMS)
Power output500VA
Max. knee voltage measurement45KV
Current measurementRange0~10A (automatically change range in 0.1/0.4/2/10A)
Error<±0.1%+0.01%FS

 

Voltage measurementRange0~200V (automatically change range in 1V/10V/70V/200V)
Error< ±0.1%+0.01%FS
Turns ratio measurement Range1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurementerror±2min
resolution0.01min
Winding resistance measurementRange0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS
Maximum resolution : 0.1mΩ
Temperature measurement-50~100 Celsius degree; error<3 Celsius degree
CT Secondary burdenRange0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error<0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm


PT Secondary burden
Error0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Maximum<0.2%RDG+0.02%FS
resolution0.1ohm

PT ratio measurement

Range
1~35000
1~10000 error<0.1%
10000~35000 error<0.2%
PT ratio error measurement :Typical error<0.05%,
Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window
Memory capacity>1000 groups test results
Working condition temperature-10℃~50℃; moist ≤90%
 

 

 

Picture of CT VT Analyer

Hot Products

ASTM D445 Manual and Cheap Kinematic Viscosity Tester Summary This instrument is suitable to ...
Existent Gum Tester for Aviation Fuel Testing Summary This tester is designed and made as per ...
ASTM D323 Gasoline and Crude Oil Vapour Pressure Test Equipment Summary This test equipment is ...
Petroleum Oils Solidifying Point&Cold Filter Plugging Point Testing Equipment Summary This ...
Moderately High Temperature Piston Deposits Apparatus by Thermo-Oxidation Engine Oil Simulation Test ...
Water Washout Tester for Evaluating the Resistance of Lubricating Grease Introduction: This test ...