Density Range 0-5 Black-White Densimeter Densitometer HUA900 Series Accurate Readings
Detailed Product Description
A Survey of the Densimeter
The densimeter developed by our company, is a quality product of
computer-assisted high technology. It
boasts accurate readings, high stability and easy operation. It can
be widely applied to the fields such as
nondestructive testing, publishing industry and medical science
etc. Every densimeter is equipped with a
density tablet for testing its precision.
Densitometer HUA-900A | (D=0.00-4.00) |
Densitometer HUA-900B | (D=0.00-4.50) |
Densitometer HUA-900C | (D=0.00-5.00) |
Technology Index
★Density Range
D=0.00 — 4.00(HUA-900A)
D=0.00 — 4.50(HUA-900B)
D=0.00 — 5.00(HUA-900C)
★Reading Stability ±0.02
★Measurement Uncertainty
0.00 — 2.00 0.02
2.00 — 4.50 0.05
4.50 — 5.00 0.08
★Power Requirements 50~60Hz, 220V±10%
★ Specifications 300×280×115(length*width*height)
★Aperture Diameter
diameter 2mm
★Display Format
three-digit number
★SamplingTime 0.8 seconds
★ Operation Environment
temperature 0℃~40℃
relative humidity ≤85%
★Power Dissipation About 25W
★Weight About 3kg
Operating Instructions:
I, Measuring Density Values:
1, Push POWER button on the lower right corner of the densimeter
after connecting it to the electricity
and on the screen will appear “-.--”. It needs 5 minutes to warm
up.
2, Push measuring arm down without putting any samples and on the
screen will appear “E.1”. Keeping
on pushing down the measuring arm while pushing the redZero Setting
button on the upper right corner
of the densimeter and on the screen will appear “0.00”. Releasing
the measuring arm, the densimeter
will enter the stage of measuring density values.
3, Align the sample with the aperture and push the measuring arm
button, its density values will be
shown on the screen.
4, While using the standard density tablet equipped with the
instrument, the zero point should be
determined first, that is, aligning the benchmark without density
tablet with the aperture, pushing down
the measuring arm and the Zero Setting button at the same time,
start test other samples till the screen
shows “0.00”.
II, Observing Samples:
The tested samples can be observed after the light on the lower
left corner of the instrument is turned
on and the trichromatic fluorescent lights inside the instrument
are lit.
Points for Attention:
Black-white densimeter is a kind of fine measuring instrument. It
should be kept away from dusts, humidity,
alkaline and acid objects, and magnetic fields.
The joint between the aperture diaphragm and the light source base
is relatively loose for the convenience
of cleaning the dusts on them. Using the cohesive tape to pull out
the aperture diaphragm first and then
using writing bush to clean the dusts are strongly recommended.
The aperture diaphragm has been glued with small cohesive tape when
leaving the plant. In order not to
lose the diaphragm, please do not taking the cohesive tape away
when moving or using the aperture
diaphragm.
Please keep the density tablet clean. Use it only when you are not
sure about the readings of the instrument.
When readings of density values are out of the prescribed range,
the measurement data are still of
reference value.