HFV-2206M LED Industry Radiographic Film Viewer & Densitometer

 

Features:

Maximum Light Intensity:> 70,000cd/㎡

Easily View < 4. 0 Density

Pure White LED Light

50,000 Hour Lamp Life

Low Power Consumption

Fan cooling

Foot Switch

Uniform Viewing Area: 98% Full Screen

Dimmer Control: 0% to 100% continuous

Surface temperature: <18°

Built-desktop stand

Design: Modern, Stylish and Simple

Power Requirements: 85-264VAC/47-60Hz

The power adapter: AC: 90-264VAC / 47-63Hz DC: 12V 5A

Safety Regulation and Electromagnetic Compatibility

 

Specifications:

Adapter Input voltage85-264VAC / 47-60Hz DC: 12V 5A Power: 60W
Maximum Light Intensity>70,000 Cd/㎡
Film density<4.0D According to the inspection report
Surface temperature<18°Celsius Continuous operation for 24 hours)
Uniform Viewing Area98% Full Screen
Dimmer Control0% to 100% continuous
Control modeManual + Foot-switch
Cooling MethodForced air cooling
Dimensions425mm*60mm*130 mm (L*W*H)
Viewer window220mm*60mm (L*W)
Viewing-mask window200 mm*40 mm (L*W)
Power50W
Weight2.5 KG

 

Package Contents:

LED viewer with densitometer HFV-2260M 1pc

Foot switch 1pc

AC power cord 1pc

Viewing mask 1pc

Magnetic film holder 2pcs

Magnetic ruler 1pc

User's manual 1pc

Calibration certificate 1pc

 

Trouble shooting Cause of the fault:

The power light is not on Elimination method: Check the power switch (8) to see if it is on the position of the foot switch, if is, should use in the foot switch mode. Check the lightness adjustment knob on the right-side control penal to see if it is on the minimum position, it is, should turn it to the proper lightness in the clockwise.

 

Hot Products

HFV-2206M LED Industry Radiographic Film Viewer & Densitometer Features: Maximum Light Intensity:> ...
Penetrate testing test specimen Model:YM-B3 All linear dimensions to the requirements of AS2083/2005...
Penetrate testing test specimen YM-C All linear dimensions to the requirements of AS2083/2005, ...
Wet Film Gauge 25-3000 μm Product Introduction: This Wet Film Gauge is used to measure the wet film ...
HUATEC Wet Film Thickness Gauges(Comb-shape) Detailed Product Description: The Wet Film Thickness ...
Wet Film Thickness Wheel Product Introduction: This Wet Film Wheel is used to measure the wet film ...