Home Companies Suzhou Sumairui Gas System Co.,Ltd.

Psa Membrane Nitrogen Generator System For Laser Cutting 200 Psi

Suzhou Sumairui Gas System Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: No 161,ZhongfengJie, Suzhou High technology district, Suzhou

Contact name:Dylan Lee

Inquir Now

Suzhou Sumairui Gas System Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Psa Membrane Nitrogen Generator System For Laser Cutting 200 Psi

Country/Region china
City & Province suzhou
InquireNow

Product Details

Fiber laser cutting membrane nitrogen generator with 200 psi for 20000W working fully automatic by CE certificates

 

How Nitrogen Generators Work


MEMBRANE SEPARATION NITROGEN GENERATOR

 

The heart of a nitrogen generator using the Membrane Separation technique is, unsurprisingly, the separation membrane. The membrane consists of thousands of hollow fibers that compressed air is passed through. The walls of each fiber are permeable to gas molecules, but some gases can pass through more easily than others. These ‘fast’ gases, including Oxygen, CO2, and water vapor, pass through the fiber walls and are exhausted to atmosphere. The ‘slow’ gas, nitrogen, passes through the fiber wall much more slowly, producing a high purity nitrogen stream at the membrane outlet. There are no moving parts to the membrane, simply controlling the pressure and flow rate of compressed air through the membrane results in high purity nitrogen production.

 

 

PRESSURE SWING ADSORPTION (PSA) NITROGEN GENERATOR

PSA nitrogen generators utilize Carbon Molecular Sieve (CMS) material to strip oxygen from the source compressed air. CMS material consists of porous carbon with finely controlled pore size. As compressed air passes over the material, oxygen molecules are adsorbed into the pores, while the larger nitrogen molecules can pass through to the exhaust gas. Eventually, the CMS will become saturated with oxygen molecules and gas separation will no longer occur.

For this reason, PSA generators are always designed with two or more adsorption columns. One column is actively separating gas, while the other one is being regenerated by passing high purity nitrogen through it to strip out the oxygen and exhaust it as waste gas. The generator switches between the two columns approximately every 60 seconds. The need for switching between the two adsorption columns results in the need for multiple automated control valves, greatly increasing the potential points of failure in the unit. Additionally, a nitrogen buffer tank is typically required to ensure a constant pressure and flow rate during the switching between the two adsorption columns.

 

Commonly Asked Question About How Nitrogen Generators Work
DO I NEED AN AIR DRYER OR ANY OTHER SPECIAL FILTRATION ON MY AIR SUPPLY?

Membrane Separation: Each generator includes in-line filtration to remove particulate, liquid water, and carry over hydrocarbons from the air stream prior to entering the separation membrane. The Air Products PRISM® membranes ECS uses are designed to filter out water vapor, eliminating the need for a refrigerated or desiccant dryer upstream of the unit.

Pressure Swing Adsorption (PSA): PSA units also typically include in-line filtration of particulates and carry over-hydrocarbons in their source air line to protect the CMS material. However, unlike Air Products PRISM® membranes, the CMS material in PSA units can be adversely affected by water/water vapor in the gas source. Water vapor would also be adsorbed by the CMS material, reducing the efficiency of the separation process and resulting in lower purity nitrogen.

 

Additionally, if there is any carryover water or if condensation occurs in the adsorption tanks, the CMS material can be damaged. Liquid water can result in the channeling of the CMS material, resulting in improper airflow through the bed and reduced production. In some cases, the CMS can be irreparably damaged, needing complete replacement. For this reason, PSA generators will always require a refrigerated air dryer on the inlet gas stream, resulting in another potential point of failure and increased electrical consumption.

 

ARE THERE ANY DIFFERENCES IN THE SIZE/WEIGHT/FOOTPRINT OF THE TWO METHODS OF NITROGEN GENERATION?

Membrane Separation: Since the membrane separation technique requires so few moving parts, ECS has been able to engineer its systems to have the smallest footprint of any nitrogen generators currently on the market. Additionally, ECS uses a fill and purge method to inert the fire sprinkler systems, eliminating the need for a nitrogen storage/buffer tank, further reducing the equipment footprint, and providing significant savings and material and labor installation costs.

Pressure Swing Adsorption (PSA): The added controls, valves, adsorption beds, refrigerated dryer, and nitrogen buffer tank required by the PSA approach result in significantly heavier and bulkier equipment. This results in higher installation costs and larger space requirements at the point of installation.

 

WHAT IS THE EXPECTED LIFE SPAN OF THE EQUIPMENT, AND WHAT IS THE RESULTING COST TO REPAIR?

Membrane Separation: Like any other product sold, there are several manufacturers of nitrogen membranes, some produce a high-quality product, and some produce a value option. Since its inception, Sumairui Gas has used Air Products PRISM® membranes which represent the highest quality of available technology. Air Products invented nitrogen membrane separation technology in the 1970s and has continued to improve upon it.

 

Currently, their membranes are designed for a twenty (20) year life expectancy at a 100% duty cycle (in the fire protection industry we use the membrane at no more than a 10% duty cycle). The cost for replacing a membrane is at most 25% of the cost of the nitrogen generator. Further, the labor involved in replacing a nitrogen membrane in the field is minimal and can be performed within an hour by a fire sprinkler fitter to get the unit back up and running and the fire protection system back in service.

Pressure Swing Adsorption (PSA): Most PSA manufacturers report that the CMS material has a typical life span of 20+ years if proper maintenance and air filtration is performed. However, what is not clear is if replacement of the CMS can be performed by onsite personnel or if it requires a manufacturer’s representative to perform the replacement. The work would involve the disassembly of the two adsorption columns, removal of the old CMS material, and repacking of the columns to original specifications with new CMS material.

 

The repacked columns would then need to be tested to ensure proper gas separation is occurring. This is a labor-intensive exercise that must be performed while the unit is out of service, resulting in loss of supervisory gas to the dry and preaction fire sprinkler systems. In addition to the CMS material, the added complexity of PSA generators adds additional points of failure to the equipment, both on the controls equipment and the automated valves that switch flow between the two adsorption columns. Any failure in these components would result in the system going out of service.


IS THERE A DIFFERENCE IN PRODUCTION RATE OR GAS PURITY BETWEEN THE TWO TYPES OF NITROGEN GENERATORS?

Nitrogen Separation Membranes can typically produce nitrogen at purities up to 99.5%, while PSA nitrogen generators can achieve purities up to 99.9995%. Realistically, the difference in potential purity between the two has no significance in the fire sprinkler industry, where 98% nitrogen purity has become the industry-wide standard for corrosion control.

 

 

 

Some of the applications that are well-suited for onsite nitrogen generating systems include:

 

autoclaves


beverage manufacturing


chemical plants and refineries


coffee packaging


controlled atmosphere fruit storage


enhanced oil field recovery


food/map packaging


fuel and chemical tank inerting


gas assist injection molding


heat treating


laser cutting


leak cutting


pharmaceutical manufacturing


printing


power plants


reflow ovens


shipboard inerting


soldering

 

 

Advantages of membrane nitrogen plant :

Why Choose Nitrogen Generator Membrane Units:

  • Extensive experience producing PSA and membrane units
  • All the facilities are ISO 9001 Certified
  • Modular design for easy installation
  • Systems designed for long-term reliability
  • Smallest physical footprint available
  • Strategic alliance with dryer and compressor suppliers
  • Extensive global service network
  • A top-rated membrane when comparing nitrogen/air ratio

 

ItemNitrogen purity (Nm3/hr)Dimensions

Weight

 

90%95%99%99.5%99.9%(L*W*H) mmKG
OSM151356123156.5450*300*1300100
OSM30270122463013550*500*1300140
OSM60540244926026900*850*1300200
OSM1201080488184120521200*1000*1500280
OSM1801620732276180781500*1200*1500400
OSM24018908543222401041800*1200*1600520
OSM300270012204603001302300*1350*1800600
OSM450405018306904501953850*1500*2000800
OSM52547252135805525227.54200*1550*2100950
OSM600540024409206002605000*1800*22501050
OSM675607527451035675292.55500*1800*23501250
OSM7506750305011507503255850*1850*24001500
OSM9008100366013809003906500*1950*24001700
OSM105094504270161010504557800*2100*24501950
OSM15001350061002300150065010500*2300*26002100
OSM180016200

7320

 

2760180078013000*2350*26002600

 

 

 

Hot Products

Membrane nitrogen generator technology with 1000CFM 500 PSI 95% purity one skid Compact configuratio...
Membrane nitrogen generator with container shell used for oil and gas offshore projects How Nitrogen ...
Beverage manufacturing membrane nitrogen generator for food industry with capacity 300 scfm 100 psi ...
300 cfm membrane nitrogen generator with CE certificates Blanketing of Chemicals and Pharmaceuticals ...
Fiber laser cutting membrane nitrogen generator with 200 psi for 20000W working fully automatic by ...
OSM high pressure Membrane nitrogen generator for Oil and Gas field Membrane nitrogen generator ...