High Precision Multiflex 6 Holes W&H Implant Handpiece 45 Degree CE Approved
W&H Fiber Optic Handpiece
Description:
6-Hole Fiber Optic Handpiece With Quick Couplin:M4/B2
Chuck Type:Push Button,Compatible with W&H ROTO Quick
Bearing:Stainless bearing
Spray:Triple water spray
Working Air Pressure:0.20-0.25MPa(0.22MPa prefrred)
Rotation Speed:350,000-400,000R.P.M(Standard Head);
280,000-320,000R.P.M(Torque Head);
Bur Applicable:Φ1.595-1.600mm
Product Parts:
Consists of handpiece head, handle, caudal thread, cartridge.
Working Conditions:
1.Air pressure 0.25~0.30mpa,must be filtrated.
2.Use high speed dental bur with shaft diameter
Φ1.59~1.60mm×21-23mm and roghtness less than 0.8um.
3.The amount of handpieces spray or water spray should be able to
adjusted.
4.Hard glass fiber,can be repeatedly sterilized in high temperautre
and pressure.
Product Scope:
Only used for drilling, molar of stomatology clamping high-speed
dental burs.
HPA012(W) Handpiece we Provide Two Kind Of Head For Choice
HPA012(W)S | HPA012(W)T |
Standard Head | Torque Head |
Features:
1.Clamping force of handpiece is:20-45N
2.Noise not exceed 70dB
3.At 25-30 atmosphele pressure,350,000-400,000R.P.M(Standard
Head);280,000-320,000R.P.M(Torque Head);
4.Optical handpiece ,3 point water spray,double air tracks, quick
coupling, light guide vitreous, illumination≥25000LUX. Voltage is
3.3V±0.1V, LED light.
Environmet-friendly fiber opitic handpiece tube:
If the dental unit don’t have the optical fiber system,please
insert our optical fiber tubing and electricity borad in the dental
ubit,
then it can use our optical fiber handpiece and inclube the high
speed handpiece which compliance with international standards.
Electricity board:
1.Power in:12-24VFIBER OPTIC HANDPIECE
2.Power out:2.5-3.5V(adjustable)FIBER OPTIC HANDPIECE
3.Output delay:0-12s(adjustable)
4.Linkage air pressure:P>0.2Mpa
5.Control ways:2 ways
Maintenance:
1.Considering safety first, please be careful to use it with full
attention.
2.Be limited to dentists who held the dental treatment
qualifications.
3.Strictly forbid decomposition and reconstruction by unauthorized.
4.Please run point testing on outside of patients oral beforehand.
If feel anomalies, please stop using immediately and contact with
our after-sales center.
5.When appears abnormal during using, please stop it immediately
and contact with our after-sales center.
6.It will cause a high noise using a center-vibration or bended bur
and a handpiece of which bearing has been worn, A long time in this
state will be harm to people’s hearing. Forbid using a vibration or
bended bur, if appear high noise, please replace the shaft core
early
7.Do not use a bending , cracking, deformation and unqualified bur.
If using it, may cause a snap, or a flying off to injury accident
during operation process.
8.Please ensure the bur chuck be clean. If with contaminant inside
of it, may causes bur clamping weaken or shaft core vibration.
9.Please run the bur under the provision rotation-speed by bur
manufacturers.
10.Do not crash, especially to avoid falling.
11.Please install a bur or a standard stick before using.
12.Aslo remember to install a bur or a standard stick when not in
using.
13.Please unload the bur and handpiece when the running stopped in
completely.