2000A 12KV Withdrawable Circuit Breaker Modularized Mechanism

Country/Region china
City & Province zhengzhou henan
Categories Other Chargers
InquireNow

Product Details

VS1-12 withdrawable Vacuum Circuit Breaker 12KV 630-2000A

Voltage: 12KV

Current: 2000A

Breaking current: 20KA

Type: withdrawable

 

 

Product overview

VS1-Series circuit breakers are complete independently developed by Knkong based on the advanced design concept; it adopts a modularized mechanism, which is easy for installation, maintenance, testing, and operation. As compared with conventional VS1 circuit breaker. it features higher operation stability, higher safety, and extended service life. The product can satisfy customers demand application in 12kv and 24kV power transmission and distribution systems, which is extensively applied in such industries as power, energy, petrochemical engineering, metallurgy, manufacture, traffic, building, and environmental protection as well as large-scale enterprises and national key projects

 

Normal service condition

Altitude≤1000m
Ambient temperatureMax+40℃
Min-15℃

Ambient humidity:

Maximum average humidity

24 hours ≤95%
1 month ≤90%
Maximum water vapor pressure24 hours ≤2.2kpa
1 month ≤1.8kpa

 

Special service condition

For special operating conditions, please consult the manufacturer:
The site altitude exceeds 1000m
-Allows to reduce the dielectric strength of air
-Or order a high prototype circuit breaker, which should meet
Corresponding insulation requirements.
Ambient temperature rise
-Reduced current carrying capacity
-Provide additional ventilation for heat dissipation
Other precautions should be negotiated with the manufacturer according to section 2.2 of IEC 62271-1

 

Technical Parameters

No.ItemUnitParameter
1Rated voltageKV12
2Rated frequencyHz50/60
3

 

Rated insulation level

1min power frequency withstand voltage(r. m. s)

 

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)

 

 

4

 

 

Rated current

 

 

A

63063012501600
1250125016002000
  20002500
  25003150
   4000
5Rated short-circuit breaking current

 

KA

202531.540
6Rated short-time withstand current202531.540
7Rated short-circuit marking current506380100
8Rated peak withstand current506380100
9Rated duration of short-circuit    s4
10Rated operating sequence O-0.3s-O/C-180s-O/C
11Breaking times of rated short-circuit currentTimes30/20 times(40KA)
12Mechanical enduranceOps20000
13Rated single capacitor bank breaking current

 

A

630
14Rated back-to-back capacitor bank breaking current400
15Double-earth fault breaking current27.4
16Allowable maximum contact erosion

 

mm

3
17Clearance between open contacts10±1
18Over stroke3.5±0.5
19Non-simultaneity of 3-phase opening and closing

ms

 

≤2
20Bounce duration of contact closing≤2
21Average breaking speed (instant breaking 6mm)

m/s

 

1.1±0.2
22Average making speed0.8±0.2
23Making time

ms

 

≤100
24Breaking time≤50

 

 

25

 

Resistance of each phase main circuit

 

μ Ω

630A≤50
1250A≤45
1600A~2000A≤35
≥2500A≤25
26Contact breaking bounce amplitudemm≤2

 

27

Rated operating voltageRated operating voltage(V)AC/DC

 

V

24*110220
Scope of normal operation voltageOpening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28Rated voltage of energy storage motorVAC110/220,DC110/220
29Energy storage timeS≤15

 

 

Operation safety

With anti-maloperation locking protection these circuit breakers, working in switchgear cabinets, can realize "five-protection" interlocking functions, avoiding malapert and maximizing the protection of an operator's personal safety.

Only when the circuit breaker and earthing switch are in the disconnected position can the truck of circuit breaker be racked to the service position from the test position

The circuit breaker can be closed only when in the service/test position.

With the circuit breaker closed its truck cannot be racked in or racked out which can be realized only when the circuit breaker is in the disconnected position.

The circuit breaker in a closed position cannot be racked out from the service position to the test position.

The circuit breaker cannot be closed while it is being racked in.

When the circuit breaker is closed, if the closing signal fails to be removed timely, the internal anti-trip control circuit will cut off the closing circuit to prevent multiple reclosing (optional).

If the electric closing lockout is selected, the circuit breaker will be unable to be closed when the secondary circuit fails to provide power or the power provided fails to meet the normal operation of the locking electromagnet(optional).

 

 

Hot Products

12KV 630A Vacuum Circuit Breaker VCB VS1 series Voltage: 12KV Current: 630A Breaking current: 25KA ...
VCB 12KV 1250A VS1 Series Vacuum Circuit Breaker Voltage: 12KV Current: 1250A Breaking current: 25KA ...
VS1 Series Vacuum Circuit Breaker 12KV 630-1250A Voltage: 12KV Current: 630-1250A Breaking current: ...
VS1-12 VCB Vacuum Circuit Breaker 12KV 2000A Voltage: 12KV Current: 2000A Breaking current: 20KA ...
VS1-12 withdrawable Vacuum Circuit Breaker 12KV 630-2000A Voltage: 12KV Current: 2000A Breaking ...
VS1-12 fixed type 205 phase spacing Vacuum Circuit Breaker 12KV 630A Voltage: 12KV Current: 630A ...