MS104K-L Single Gas Detector

 

OVERVIEW

 

All cases require portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, flue gas analysis, air management, etc.

 

The main functions of the MS104K-L portable gas detector are to The main functions of the MS104K-L portable gas detector are to quickly and accurately detect gas leaks or gas concentrations exceeding the alarm limit. The main detection principles of gas detection are: electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionisation, etc. The MS104K-L is widely used in firefighting, emergency rescue, confined space, petroleum, chemical industry, metallurgy, refining, gas, storage, medicine, environmental protection, air treatment and other occasions.

 

FEATURES

 

● Built-in pump suction measurement, can be switched of diffusion + pump suction mode.

Pump Suction Alarm.

Customizable LED lighting.

● Unit  switching for free, unit optional: umol/mol, ppm, pphm, ppb, mg/m3, ug/m3, %Vol, %LEL.

● 8-button operation, quick one-key calibration function.

● Data storage: the capacity of storage can be not less than 100,000 items.

● Communication interface: TYPE-C. BluetoothFall alarm(option: ).

● Data recovery function, partial or full recovery of factory data.

● Maximum value/minimum value/ weighted average value display.

Multiple Alarm Methods: sound and light alarm, vibration alarm, voice alarm Alarm type: Concentration alarm, under pressure alarm, fault alarm, pump blockage alarm. Alarm mode: low alarm, high alarm, interval alarm, TWA/STEL alarm.

Misuse function recognizable, concentration calibration misoperation is automatically recognized and blocked.

Zero-point auto-tracking Avoids zero-point drift. 

Multi-stage calibration of target points.

● Intrinsically safe circuit design, explosion-proof, shock-proof, anti-static, anti-radiation.

● Protection class IP68, Rain, dust and corrosion resistance.

 

APPLICATION

 

It is widely used in areas where explosion-proof is required or toxic gas leaks, like underground channels or the mining industry, so as to protect the worker's life and avoid damage to the relevant equipment.

 

PARAMETER

 

Detection FactorSingle gas (carbon monoxide CO, hydrogen sulfide H2S, oxygen O2, combustible gas Ex, carbon dioxide CO2, VOC, etc.), depending on the site environment and user requirements
Detection RangeDepends on the site environment and user needs
Resolution0.001ppm (0-10ppm high accuracy)/0.01ppm (0-10 ppm); 0.01ppm (0-100 ppm), 0.1ppm (0-1000 ppm), 1ppm (0-1000 ppm or more); 0.1%LEL;0.1%, 0.01%Vol
Detection PrincipleElectrochemical, catalytic combustion, infrared, thermal conductivity, semiconductor, PID photoionization, etc., depending on the range, site environment and user needs
Sensor lifeElectrochemical 2-3 years, catalytic combustion 2-3 years, infrared 5-10 years, thermal conduction 2-5 years, PID 2-3 years
Measuring methodBuilt-in pump suction, can be switched to diffusion, diffusion + pump suction detection mode
DisplayLCD
Display contentReal-time concentration, unit, gas name, alarm status, time, storage status, communication status, power, charging status, etc.
Detection accuracyTypical precision: ≤±3% FS (optional higher precision sensor)Uncertainty≤±2%
Linearity≤±3%Repeatability≤±2%
Response timeT90≤20 secondsRecovery time≤30 seconds
Operating power supplyDC3.7 V*2
Battery capacity2500mAh rechargeable polymer battery, with over-charge, over-discharge, over-voltage, short-circuit, overheating protection function.
EnvironmentTemperature: -20℃~+60℃, customizable -40℃~+70℃; Relative humidity: 10-95%RH
Communication InterfaceStandard Type-C (2 hours fully charged)
Data storageStandard capacity of not less than 100,000 items; support for local view, delete or data export, storage time interval arbitrary
settings
Interface languageChinese, English and other languages can be customized
Explosion-proof typeIntrinsically safe ExiaⅡCT4Ga
Protection classIP68
Housing materialHigh-strength corrosion-resistant fire-resistant polycarbonate and rubber protective cover, drop-proof wear-resistant anti-static,effective drop resistance ≥ 5 meters
DimensionMaximum size 167X64X62mm(L×W×H)
WeightApprox. 280g
Standard accessoriesCalibration cover, pump suction nozzle, manual, certificate of conformity, USB charger (including data cable), instrument
packaging color box
Optional accessories① 0.2 meters swan neck sampling probe;
② activated carbon filter;
③ 0.4 meters stainless steel sampling handle (including 1 meter hose);
④ 0.9 meters retractable sampling handle (including 1 meter hose);
⑤ External Bluetooth printer.

 

Detected GasesRangeMinimum ReadingDetected GasesRangeMinimum Reading
VOCs(VOC)0-20ppm0.01ppmEthylene oxide (ETO)0- 100%LEL0. 1%LEL
VOCs(VOC)0-200ppm0. 1ppmPhosgene(COCL2)0- 1ppm0.001ppm
VOCs(VOC)0-2000ppm1ppmPhosgene(COCL2)0- 10ppm0.01ppm
VOCs(VOC)0- 10000ppm1ppmSilane(SiH4)0- 1ppm0.001ppm
Gas (EX)0- 1000ppm1ppmSilane(SiH4)0-50ppm0.01ppm
Gas (EX)0- 100%LEL0. 1%LELFluorine gas (F2)0- 1ppm0.001ppm
Gas (EX)0- 100%VOL0.01%VOLFluorine gas (F2)0- 10ppm0.001ppm
Methane (CH4)0- 100%LEL0. 1%LELFluorine gas(F2)0- 100ppm0.01ppm
Methane (CH4)0- 100%VOL0.01%VOLHydrogen Fluoride (HF)0- 10ppm0.01ppm
Oxygen (O2)0-30%VOL0.01%VOLHydrogen Fluoride (HF)0-50ppm0.01ppm
Oxygen (O2)0- 100%VOL0.01%VOLHydrogen Bromide(HBr)0-50ppm0.01ppm
Carbon Monoxide (CO)0- 100ppm0.01ppmEthylborane(B2H6)0- 10ppm0.001ppm
Carbon Monoxide (CO)0- 1000ppm0. 1ppmArsine(AsH3)0- 1ppm0.001ppm
Carbon Monoxide (CO)0-2000ppm1ppmArsine(AsH3)0- 10ppm0.001ppm
Carbon Monoxide (CO)0-5000ppm1ppmGermanium(GeH4)0- 1ppm0.001ppm
Carbon Monoxide (CO)0- 10000ppm1ppmGermanium(GeH4)0- 10ppm0.001ppm
Carbon dioxide (CO2)0-5000ppm1ppmGermanium(GeH4)0-50ppm0.01ppm
Carbon dioxide (CO2)0-50000ppm1ppmHydrazine, hydrazine hydrazide (N2H4)0- 1ppm0.001ppm
Carbon dioxide (CO2)0-5%VOL0.01%VOLHydrazine, hydrazine hydrazide (N2H4)0-300ppm0. 1ppm
Carbon dioxide (CO2)0-20%VOL0.01%VOLTetrahydrothiophene (THT)0-50mg/m30.01 mg/m3
Carbon dioxide (CO2)0- 100%VOL0.01%VOLBromine (Br2)0- 10ppm0.01ppm
Formaldehyde (CH2O)0- 10ppm0.01ppmBromine gas (Br2)0-50ppm0.01ppm
Formaldehyde (CH2O)0-50ppm0.01ppmSulfur dioxide (SO2)0-20ppm0.01ppm
Formaldehyde (CH2O)0- 100ppm0.01ppmSulfur dioxide (SO2)0- 100ppm0.01ppm
Formaldehyde (CH2O)0- 1000ppm1ppmSulfur Dioxide(SO2)0- 1000ppm0. 1ppm
Ozone (O3)0- 1ppm0.001ppmSulfur dioxide (SO2)0-5000ppm1ppm
Ozone (O3)0- 10ppm0.01ppmNitric oxide (NO)0-20ppm0.01ppm
Ozone (O3)0- 100ppm0.01ppmNitric Oxide (NO)0- 100ppm0.01ppm
Ozone (O3)0-2000ppm1ppmNitric Oxide (NO)0- 1000ppm0. 1ppm
Hydrogen Sulfide (H2S)0- 10ppm0.01ppmNitric Oxide (NO)0-5000ppm1ppm
Hydrogen sulfide (H2S)0- 100ppm0.01ppmNitrogen Dioxide (NO2)0-20ppm0.01ppm
Hydrogen sulfide (H2S)0-500ppm0. 1ppmNitrogen dioxide0- 100ppm0.01ppm
Hydrogen sulfide (H2S)0-2000ppm1ppmNitrogen dioxide0- 1000ppm0. 1ppm
Hydrogen Cyanide(HCN)0- 100ppm0.01ppmNitrogen Dioxide (NO2)0-2000ppm1ppm
Hydrogen Chloride(HCL)0-20ppm0.01ppmNitrogen Oxides (NOX)0- 100ppm0.01ppm
Hydrogen chloride (HCL)0-200ppm0. 1ppmNitrogen Oxides (NOX)0-500ppm0. 1ppm
Phosphine (PH3)0-5 ppm0.001ppmNitrogen oxides (NOX)0-2000ppm1ppm
Phosphine (PH3)0-20 ppm0.01ppmChlorine (CL2)0-20ppm0.01ppm
Phosphine(PH3)0-2000 ppm1ppmChlorine (CL2)0-200ppm0. 1ppm
Chlorine dioxide (CLO2)0- 1ppm0.001ppmAmmonia (NH3)0- 10ppm0.01ppm
Chlorine dioxide (CLO2)0- 10ppm0.01ppmAmmonia (NH3)0- 100ppm0.01ppm
Chlorine dioxide (CLO2)0- 100ppm0.01ppmAmmonia(NH3)0- 1000ppm0. 1ppm
Ethylene oxide (ETO)0- 100ppm0.01ppmAmmonia gas (NH3)0-5000ppm1ppm
Ethylene oxide (ETO)0- 1000ppm0. 1ppmAmmonia(NH3)0- 100%LEL0. 1%LEL

 

 

 

 

 

 

 

Hot Products

AT 7000 Portable Alcohol Detector OVERVIEW AT7000 is a newly developed alcohol tester with rapid ...
AT 7200 Portable Alcohol Detector OVERVIEW AT7200 is a newly developed alcohol tester with rapid ...
AT 7200 Portable Alcohol Detector OVERVIEW AT7200 is a newly developed alcohol tester with rapid ...
Zetron MIC100 best selling Online Gas Monitoring System Industrial Carbon Monoxide Fixed CO Gas ...
MS104K-L Single Gas Detector OVERVIEW All cases require portable rapid detection of gas concentratio...
UVOZ-3000 Ozone Detector OVERVIEW This ozone concentration analyzer adopts dual optical path UV ...