Home Companies Guangdong Morui Environmental Technology Co.,Ltd.

Anti Bacterial Ro Uf Membrane External Pressure Type No Second Pollution

Guangdong Morui Environmental Technology Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Room 906,Fuhai Wenchuang Park,Baoan District,Shenzhen,Guangdong Province,China

Contact name:Benson

Inquir Now

Guangdong Morui Environmental Technology Co.,Ltd.

Anti Bacterial Ro Uf Membrane External Pressure Type No Second Pollution

Country/Region china
City & Province shenzhen guangdong
Categories Water Treatment
InquireNow

Product Details

Anti Bacterial Ro Uf Membrane External Pressure Type No Second Pollution

 

NaCI rate of removal %40-6080-95
MgSO4 rate of removal%>96>96
NaCI average water (GPDm³/h)12000(45.5)7500(28.4)
MgSO4 average water (GPDm³/h)10000(37.5)9000(33.9)
Effective membrane area ft2(m2)400(37.2)400(37.2)
Operating pressure psi(Mpa)70psi(0.5mpa)70psi(0.5mpa)
Test temperature25℃25℃
Test liquid concentration(NaCI or MgSO4)2000ppm2000ppm
The test liquid PH7.57.5
Recovery rate(%)1515
Max.operating pressure psi(Mpa)600(4.14)600(4.14)
Max.inflow temperature(℃)4545
Max.inflow SDI55
Max.water flow GPM(m3/h)75(17)75(17)
Free chlorine concentration<0.1<0.1
Continuous running water pH range3--103--10
Chemical cleaning water pH range2--122--12
Max.single membrane element pressure drop psi(Mpa)15(0.1)15(0.1)

 

1. Effective bacterial destruction
2. Effective depyrogenation (endotoxin reduction)
3. Efficient destruction of organic contamination
4. Reduced occurence of chemical by-product formation
5. Minimal residue of chemical interference
6. Economical and easy-to-use cleaning age

 

Important information

Proper start-up of a UF system is essential to prepare the membranes for operating service and to prevent membrane damage. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved. Before initiating system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration and other system checks should be completed. Please refer to the product technical manual.

Operation guidelines

Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. Flush the UF system to remove shipping solution prior to start up. Remove residual air from the system prior to start up. Manually start the equipment. Target a permeate flow of 60% of design during initial operations. Depending on the application, permeate obtained from initial operations should be discarded. Please refer to the product technical manual.

General information

If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty (Form No. 795-00027) will be null and void.

To prevent biological growth during system shutdowns, it is recommended that preservative solution be injected into the membrane modules.

Regulatory note

NSF/ANSI 61 certified drinking water modules require specific conditioning procedures prior to producing potable water. Please refer to the product technical manual flushing section for specific procedures. Drinking water modules may be subjected to additional regulatory restrictions in some countries. Please check local regulatory guidelines and application status before use and sale.

 

 

 

package

 

 

 

Why choose us:

 

- Best quality with reasonable price

- Offer OEM services for all customers

- Fast ,accurate quotes and flexible payment

- Strong technical surpport,20 more year experience

- Membrane high mechanical strength, stable water quality, operation flux is big, long service life

Hot Products

8060 Ultrafiltration Module Industrial Water Filter System Uf Membrane Product features: 1, ...
High Strength Ultrafiltration Membrane Filter Domestic Wastewater Treatment NaCI rate of removal % ...
Professional Uf Hollow Fiber Membrane For Mineral Water Plant Purification NaCI rate of removal % 40...
Water Treatment Ultrafiltration Membrane 8060 CE ISO9001 ISO Certification NaCI rate of removal % 40...
Anti Bacterial Ro Uf Membrane External Pressure Type No Second Pollution NaCI rate of removal % 40...
External Pressure Ultrafiltration Membrane Anti Fouling PVDF Material NaCI rate of removal % 40-60 ...