Home Companies Shenzhen zk electric technology limited company

150A 75Kw MPPT VFD Solar Pump Inverter For Agriculture Forestry Irrigation

Shenzhen zk electric technology limited  company
Active Member

Contact Us

[China] country

Address: Room 617, Guanlida Building, NO. 269 of Qianjin Road, Wenhui community, Xin'an street

Contact name:Frank

Inquir Now

Shenzhen zk electric technology limited company

150A 75Kw MPPT VFD Solar Pump Inverter For Agriculture Forestry Irrigation

Country/Region china
Categories Inverters & Converters
InquireNow

Product Details

 

Three Phase 220V 380V Output 75Kw 150A Solar Pump Drive With Mppt Function For Agriculture And Forestry Irrigation

 

ZK Solar Pump Inverter Features

 

1.In-built MPPT and efficiency up to 99.6%

 

2.20 kinds of protection level.

 

3.Save energy costs and maximize productivity.

 

4.The drives can be equipped with remote monitoring options, reducing maintenance trips to the site.

 

5.Configuring. end user ,who never used inverter before, can Install and operation it very well.

 

6.Easy install and operation and little parameterEmbedded pump-specific features such as dry run detection,minimum power input protection,

maximum current protection,stop frequency running protection.

 

 

Technical Specification

 

Recommended MPPT voltage rangeVmpp 131 to 350 VDC for 1S (80V to 350VDC input, 3PH 110 to 220VAC output)
Vmpp 280 to 375VDC for 2T ( 150V to 350VDC input, 3PH 220 to 240VAC output)
Vmpp 486 to 800 VDC for 4T ( 250V to 900VDC input, 3PH 380 to 460VAC output)
Recommended input voltage (Voc and Vmmp)Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps
Voc 355(VDC), Vmpp 310(VDC) for 2T model or 220V AC pumps
Voc 620(VDC), Vmpp 540(VDC) for 4T model or 380V AC pump
Motor typeControl for permanent magnet servo motor and asynchronous motor pumps.
Input powerDC power from solar arrays or AC grid power
Maximum DC power input450VDC for 220-240VAC output /900VDC for 380-460VAC output
Rated output voltage3-phase , 110V/160V/220V. 3-phase, 220V/240V/380V/460V/480V
Output frequency range0~50/60Hz
MPPT efficiency97%,
Ambient temperature range(G-type inverter with submersible pumps, and P type for general pumps.
Solar pump control special performanceMPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation,
dry run protection, low stop frequency protection, minimum power input, motor maximum
current protection, flow calculating, energy generated calculating
Protection functionPhase loss protection, phase short circuit protection , ground to phase circuit protection , input
and output short circuit protection. Stall protection
Protection degreeIP20, Air force cooling
Running modeMPPT , CVT, variable frequency mode
AltitudeBelow 1000m; above 1000m, derated 1% for every additional 100m.

 

Wiring description:

 

 

 

 

 

 


It is accepted dual power AC/DC mode connecting input.

 

User can able to install a power switchover to selection which mode power input as conditions.

 

Wiring P+ and P- of DC solar power to R, T terminals, or 1/3 phase cables of AC power supply to R, T ( R, S, T) of inverter. Connect 1 phase 220VAC AC input L, N to R and T terminals of inverter.

 

Built a Run/Stop switch S1 to start pumping when setting P0.02 for 1,that inverter works in terminals control mode. This inverter can achieve auto start at morning when sun light radiation is good, auto stop when sunset when sunlight radiation is low.

 

 

Built a switch 2 to disable solar pump control mode when connecting AC grid input. The inverter can be used for a variable speed drive (VFD) for pumps speed adjusting as need The output frequency can be adjusted by P0-03 frequency reference mode setting. The MPPT function is closed when turn off switch 2 and set P4.02=53. The solar pump control mode function also can be disable by parameters setting PE00=0

.

Connect 2 wires of float ball sensor to DI4 and COM for water tank level fulling detecting, and set P4.03=51( float ball NO relay alarm). When water level reached to sensor detecting, the normal open (NO) relay point will be activated, inveretr stop pumping, and sent a A.FuL alarm.

Connect 2 wires of sensor of dry run sensor of well to DI5 and GND, and set F4.04=52 ( dry run NC relay alarm). It will sent alarm A.LLd and stop pumping when lack of water in well for dry run protection.

Hot Products

Most Popular Power Sg600 220v 2.2kw 380v 4kw Mppt Solar Vfd Drive Inverter In India solar controller ...
Inversor bomba sumergible solar vfd pump drive inverter pump controller Features: Solar Frequency ...
High Protection IP54 Higher Waterproof 4KW To 22KW 380V Mppt Vfd Solar Pump Inverter ZK SD600 Series ...
22kw Solar Irrigation System Metal Cover Solar Pump Inverter Model:SG600-022GB-4T Solar Pumping ...
Three Phase 220V 380V Output 75Kw 150A Solar Pump Drive With Mppt Function For Agriculture And ...
AC/ Generator/ Solar water pumping inverter for farm Solar pumping system can provide water for ...