MDC Micro Data Center Solutions Integrated Cold Aisle Single Row UPS 90kVA

Country/Region china
City & Province shenzhen guangdong
Categories Uninterrupted Power Supply (UPS)
InquireNow

Product Details

LIRUISI Data Center Integrated Computer Room Cold Aisle Single-Row VMDC-40-RRS

Product Introduction:

LIRUISI-RAW integrated single-row data center adopts modular design, which can meet the flexible composition of 1 (1-8) single-cabinet micro-module, directly coupling and splicing between cabinets, forming a double air duct closure on the hot and cold side, integrating the power supply and distribution system, air conditioning system, cabinet system, closed channel system, monitoring system and wiring system, and configuring various environmental data sampling sensors, bringing safe, reliable, compact and convenient computer room deployment experience to unused users.

 

The micro module data center single line solution fully considers standardized design, energy conservation, and capacity expansion compatibility. It uses standardized power supply, refrigeration, and cabinet units to help it experts seamlessly plan, expand, and manage these key infrastructure in the future of the data center.

 

Application scenarios:

smart finance, smart education, smart healthcare, smart government, smart transportation, smart security, can be applied to dust and wet environments. There is no dedicated computer room space.

 

Product parameters:

Modelcustom made
Number of cabinetsLess than 20
Number of IT cabinetsLess than 20
Power Density -kW/CabinetLess than 15kW/cabinet
Redundancy typeN/N+1/2N
DEPTH X LENGTH X HEIGHT - MM: Custom on demand
system 
UPS capacity -kVAMAX 90kVA
UPS class managementRack/Module
Battery configuration (1 hour)Custom on demand
PDUCustom on demand
Total Input Power SpecificationsCustom on demand
Refrigeration system
Refrigeration typeWind, cold, cold, frozen water
Air conditioning configuration - kWPer Situation
Air conditioning typeRow level/rack/top mounted
Emergency ventilationAuto pop
Monitoring functionOptional video, access control, audible and visual/SMS alarm, centralized monitoring, etc

Hot Products

LIRUISI-ROW Series Micromodule Room Dedicated Single-Row System Black Product Introduction: 【 ...
LIRUISI Single-Row Cold Aisle Enclosed Micromodule Room Dedicated VMDC-30-RRS Product Introductionof ...
LIRUISI Data Center Integrated Computer Room Cold Aisle Single-Row VMDC-40-RRS Product Introduction: ...
LIRUISI ROW Series Modular Room Single-Row System VMDC-06-RRS Product Introduction: The single-row ...
LIRUISI Data Center Integrated Computer Room Cold Aisle Single-Row VMDC-40-RRS Product Introduction: ...
Single Row Scheme Of Micro Module Data Center Energy Saving And Capacity Expansion Compatibility ...