NBSe BF62 Series Residual Current Circuit Breaker, rcd switch

 

 

NBSL1-100 series residual current circuit breakers are applied to the lines with AC 50/60Hz,rated voltage of230V(1P+N) or 400V(3P+N),and rated current of 100A.In case of electric shock or electric leakage current exceeds the specified value, the residual current circuit breaker can switch off the fault circuit in a very short time, protecting the safety of person and electric equipment.

Can be used in the industrial, commercial, high-rise buildings, civil residences and other places.

 

Characteristics

· Phase (line) and Neutral both wires connected through RCD.

· It trips the circuit when there is earth fault current.

· The amount of current flows through the phase (line) should return through neutral .

· It detects by RCD. any mismatch between two currents flowing through phase and neutral detect by -RCD and trip the circuit within 30Miliseconed.

· If a house has an earth system connected to an earth rod and not the main incoming cable, then it must have all circuits protected by an RCD (because u mite not be able to get enough fault current to trip a MCB)

· RCDs are an extremely effective form of shock protection

 

The most widely used are 30 mA (milliamp) and 100 mA devices. A current flow of 30 mA (or 0.03 amps) is sufficiently small that it makes it very difficult to receive a dangerous shock. Even 100 mA is a relatively small figure when compared to the current that may flow in an earth fault without such protection (hundred of amps)

A 300/500 mA RCCB may be used where only fire protection is required. eg., on lighting circuits, where the risk of electric shock is small.

 

 

APPLICATION

 
A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device that quickly breaks an electrical circuit to prevent serious harm from an ongoing electric shock.
 

· Line voltage independent RCCB for fault or additional protection with additional digital features

· System Monitoring: Preventive information / warning before the RCD trips in case of leakage currents: Integrated auxiliary contact(s), Local Indication

· New level of accuracy - Reduced unwanted tripping

· Local status indication of residual current through 3 LEDs

· No monthly test required

· Comprehensive range of accessories

· Real contact position indicator

· Fault current tripping indicator

· Automatic re-setting possible

· Transparent designation plate

 

TECHNICAL PARAMETER

 

Technical Parameter
Spec Parameter
Rated Operating voltage(Ue)230V(1P+N)/400V(3P+N)
Rated Current(In)16,25,32,40,50,63,80,100
Tripping TypeElectronic,Electromagnetic
CharacteristicA type, AC type, S type
Poles1P+N,3P+N
Rated Frequency50/60Hz
Rated Insulation voltage(Ui)500V
Rated residual current (IΔn)10,30,100,300mA
Rated residual switching on and800A
breaking capacity(IΔm)
Rated residual short-circuit current6000A
limit(IΔc)
Rated short-circuit current limit(Inc)6000A
Rated switching on and breaking capaity(Im)800A
Maximun breaking time(IΔm)0.3s
Rated impulse withstand voltage(Uimp)6kV
Mechanical life(times)>10,000 times
 
Standard Certificate
Comply with StandardIEC 61008
GB 16916
CertificateCE, CB, RoHS,WEEE

 

Working Envirnment
Humidity40℃ humidity notexceed 50% 20℃ humidity not exceed 90%
(Condensation on the product due to
changes in humidity has been considered)
Working Temperature-5℃~+40℃ and its average over aperiod of 24h does not exceed
Magnetic fieldNo more than 5 times the geomagnetic field
Pollution level2
Altitude(m)2000
 
Mounting and Wiring
Shock and vibrationShould be installed in the case of no obvious impact vibration
Installation category
Terminal connection typestype cable,type U bus, TH 35mm Din-rail
Wiring terminal connection conductor1.5~25 mm²
Wiring terminal copper size25 mm²
Tightening torque3.5N*m
Installation modeUsingTH35-7.5 profile installation, the title of
installation face and vertical face is not greater than5°
Wiring incoming modeupper and lower incoming is possible for ELM type,
only upper incoming for ELE type


3. OPERATION PRINCIPLE FIG.

 

 

4. WORKING PRINCIPLE

 

 

FAQ:
Q1: What's your product Range?
A.
- Shell Unti-fire. nylon pa66 or not unti-fire.
- Parts, Copper or iron
- Point Sliver point or Copper point
 
Q2: Are you a manufacturer?
A. Yes, we are only produce the circuit breaker over 20 years from 1999.
 
Q3: Do you have stock products to sell?
A. No,we work on OEM orders, The means, material, quantity,packing solution,etc will depend on your requests.obviously, your logo can be printed on the products.
 
Q4. what's the payment term?
A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q5. how's the delivery time ?
A. usually it will take about 30 days for 30000pcs
 
Q6. tell me the standard of package?
A. Normally are cartons, color box or white box
 
Q7. what kind of material of circuit breaker?
A. we have two types, one copper coil with silver point and the other is brass coil with copper point. It depends on your requirement. In fact, those two have no difference if normal work well. Only except the electrical life. Copper and silver is better and also higer price.
Q8. We want to know month capacity.
A. 400,000pcs/month
Q9. Where is your market?
A. Our products are popular in Western Europe, Middle-East, Afirca, South Asia ,South Ameirca countries and area. Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q10. what kind of certificate you have ?
A. CE, CB,CCC,ISO9000.
 
Q11. Do you inspect the finished products
A. Yes.Each step of products will be inpected by QC department before shipping.
 
Q12. How are you ship the finished products?
- By Sea
- By plane
- By counties,TNT, DHL,FEDEX,UPS.etc.
 
 

Hot Products

NBSe BF62 Series Residual Current Circuit Breaker, rcd switch 1. APPLICATION A residual-current ...
RCCB BF60 Specification.pdfBF60 Series 2P 63A,30mA Residual Current Circuit Breaker,rcd circuit ...
BFL64 Series 4P 63A,30mA Residual Current Circuit Breaker,rccb circuit breaker 1. APPLICATION F360 ...
NBSe ID Series 2P 40A,30mA Residual Current Circuit Breaker,rcd protection Construction Features: ...
NBSe BF62 Series Residual Current Circuit Breaker, rcd switch NBSL1-100 series residual current ...
NBSe NBSB6-63LM Series Differential Circuit Breaker RCCB 2P 63A 30mA CL.AC TYPE I DOMAE Product ...