VAT CPAP Trilogy Noninvasive Ventilator Low pressure Alarm

Country/Region china
City & Province changsha hunan
Categories Smoke Detector
InquireNow

Product Details

Specifications
 

ParameterST-30H
Ventilation modeS/T, CPAP, S, T, PC, VAT
Oxygen concentration21%~100%, (increment by 1%)
Screen size5.7 Inch color screen
Waveform displayPressure/flow
IPAP4~30cm H2O
EPAP4~25cm H2O
CPAP4~20cm H2O
Target tidal volume20~2500mL
Backup BPM1~60BPM
Backup time0.2~4.0S
Rise time1~6 level
Ramp time0~60min
Ramp pressureCPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief1~3 level
Spontaneous Timin0.2~4.0S
Spontaneous Timax0.2~4.0S
I-Trigger settingAuto, 1~3 level
E-Trigger settingAuto, 1~3 level
Trigger lockOff, 0.3~1.5S
Flow of HFNC modeN/A
Max flow210L/min
Max leak compensation90L/min
Method of pressure measureThe pressure testing tube is on mask side
Alarms

Apnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|

Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|

Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted

Apnea alarm range setting0S, 10S, 20S, 30S
Disconnection alarm range setting0S, 15S, 60S
Real-time monitoring data

Present oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|

Current leakage|Current volume|Trigger method

Other settingsScreen lock|Display brightness| Flow|Pressure| Waveform
Backup battery8 hours


Description

 

Noninvasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy. NIV delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.

 

Noninvasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.

 

NIV works by creating a positive airway pressure - the pressure outside the lungs being greater than the pressure inside of the lungs. This causes air to be forced into the lungs (down the pressure gradient), lessening the respiratory effort and reducing the work of breathing.

 

Application

 

Chronic Obstruction Pulmonary Disease: The use of non-invasive ventilation (NIV) to support patients during acute decompensated respiratory failure secondary to an exacerbation of chronic obstructive pulmonary disease has unequivocal evidence of benefit in terms of reduction in the need for intubation, length of hospital stay and mortality.

 

Acute respiratory failure: Non-invasive mechanical ventilation has been increasingly used to avoid or serve as an alternative to intubation. Compared with medical therapy, and in some instances with invasive mechanical ventilation, it improves survival and reduces complications in selected patients with acute respiratory failure.
 
Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings and that it is more beneficial when applied earlier rather than as a rescue therapy.
 
Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections. A study has shown significantly more infectious complications related to the presence of the endotracheal tube.
 


 
Advantage
 

Maximum inspiratory pressure: 30cm H2O, Max flow:210L/min.

 

AST-Automatic Sensitivity Technology provide the doctor convenience no need to set the sensitivity manually, and lower down patient’s respiratory power. Premium technology will monitor patients’ every single respiration, response immediately to synchronize patients’ breath through sensitivity trigger by detecting flow, pressure and waveform changing.

 

Accurate oxygen concentration control, better oxygenation. Oxygen concentration preset and automatic oxygen control can be directly connected to hyperbaric oxygen (0.3~0.6MPa) with 21~100% oxygen concentration preset. The combination of proportional valve and flow monitoring offers automatic control of constant oxygen concentration.

 


 

 

Hot Products

Specifications Parameter ST-30H Ventilation mode S/T, CPAP, S, T, PC, VAT Oxygen concentration 21%...
CPAP Non Invasive Ventilator Machine Specifications Parameter ST-30H Ventilation mode S/T, CPAP, S, ...
Micomme Non Invasive Ventilator Machine Specifications Parameter ST-30H Ventilation mode S/T, CPAP, ...
Non Invasive Ventilator Machine 210L/min flow Description Noninvasive ventilation (NIV) supports the ...
High Performance Non Invasive Ventilator Machine Specifications Parameter ST-30H Ventilation mode S...
Non Invasive Ventilator Machine Specifications Parameter ST-30H Ventilation mode S/T, CPAP, S, T, PC...