Micomme Respiratory Support High Flow Nasal Cannula Oxygen Therapy Device

 

Description

HFNC (often referred to as high-flow) systems are broadly defined as systems that provide an oxygen-gas mixture at flows that meet or exceed a patient’s spontaneous inspiratory effort.


High-flow nasal cannula (HFNC) has become a frequently used non-invasive form of respiratory support in acute settings, however evidence supporting its use has only recently emerged.

 

High Flow Nasal Cannula (HFNC), isn't just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% FiO2 at flow rates of up to 70 liters/min. The flow rate and FiO2 can be independently titrated based on your patient's flow and FiO2 requirements.

 

 

Applications
  • Acute hypoxic respiratory failure (ARF) was the first condition treated with HFNC in adults. The use of heated and humidified high flow nasal cannula (HFNC) has become increasingly popular in the treatment of patients with acute respiratory failure through all age groups.
  • Post Surgical Respiratory Failure
  • Acute Heart Failure /Pulmonary edema
  • Hypercapnic Respiratory Failure, COPD
  • Obstructive Sleep Apnea

 

 

 

 

Advantage

At present, micomme occupies over 50% market share in high flow filed in China.

 

During the pandemic, micomme provided over 7000 units of devices globally.

 

Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 

Effectively reduce the dead space with 70L/min high flow.

 

Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.

 

  

 

Specifications

 

 

ModelOH-70C
Oxygen AdjustmentSettingAutomatic
Range21%-100%

 

Flow

Low flow mode2-25L/min
High flow mode10-70L/min
Temperature settings31℃-37℃
Real time monitoring parametersFlow, FiO2, Temperature, Treatment time

 

 

 

Data

Trend review1,3,7 days review
Content of reviewFlow, FiO2, Temperature, Treatment time
Presetting of treatment timeYes

 

 

Management

Auto reminder of maintenanceYes
Main device disinfection

No need disinfection for circuits system

Wipe disinfection for device surface

Screen4.3 inches
Dimension340*228*162mm
Weight3.3kg

 

 

 

Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, reaching present treatment time alarm

 

Hot Products

MICOMME HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30H with 8-HOUR BACK-UP BATTERY Description Non...
MICOMME HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30H with 210L/min MAX FLOW Description Non...
MICOMME HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30H with 90L/min MAX LEAK COMPENSATION ...
5.7-Inch LCD Color Screen Micomme High Performance Non-Invasive Ventilator ST-30H Description ...
Specifications Parameter ST-30H Ventilation mode S/T, CPAP, S, T, PC, VAT Oxygen concentration 21%...
CPAP Non Invasive Ventilator Machine Specifications Parameter ST-30H Ventilation mode S/T, CPAP, S, ...