Home Companies Hunan Micomme Medical Technology Development Co., Ltd.

7Days Trend Review High Flow Nasal Cannula Device

Hunan Micomme Medical Technology Development Co., Ltd.
Active Member

Contact Us

[China] country

Address: 8, Lujing Road, High- Tech Zone, Yuelu Changsha, China

Contact name:Ellen He

Inquir Now

Hunan Micomme Medical Technology Development Co., Ltd.

7Days Trend Review High Flow Nasal Cannula Device

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

 Micomme Medical 7Days Trend Review High Flow Nasal Cannula Device 70C

 

Description

A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.

 

HFNC is a simple system with clinical effects mainly dependent on flow, oxygen concentration, and temperature setting.

 

HFNC is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates.

 

 

Application

When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!

 

The main physiological effects of HFNC are maintenance of a known stable alveolar FiO2, optimal humidification of the airway mucosa, reduction of the dead space, generation of a positive end-expiratory pressure (PEEP), ultimately yielding a reduction in the respiratory drive and in the work of breathing.

 

 

Advantage

In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.

 

In 2020, micomme ranked the sixth in export of medical respiratory devices in China.

 

 Automatic O2 concentration control technology

  • 21%~100% O2 concentration adjustable with 1% adjusting precision.
  • Built-in oxygen-gas mixture to accurately control oxygen and adjust oxygen concentration. 

 

 Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.

 

Effectively reduce the dead space with 70L/min high flow

 

 

Specifications

ParametersOH-70C
Oxygen Adjustment SettingAutomatic
Oxygen Adjustment Range21%- 100%
Low flow mode2- 25L/min
High flow mode10- 70L/min
Temperature settings31℃- 37℃
Real time display parametersPreset Flow, Preset FiO2, Preset Temperature, Treatment time
Trend review1,3,7 days review
Content of reviewFlow, FiO2, Temperature, Treatment time
Presetting of treatment timeYes
Auto reminder of maintenanceYes
Main device disinfectionNo need disinfection for circuits system
Wipe disinfection for device surface
Screen

4.3 inches

Dimension340*228*162mm
Weight3.3kg
AlarmTube alarm, oxygen pressure alarm, blocking alarm, water level alarm,
temperature alarm, power down alarm, low ambient temperature alarm,
FiO2 not reaching preset value alarm, flow not reaching preset value
alarm, reaching preset treatment time alarm

 

 

Hot Products

Micomme HFNC devices 10-70L/Min High Flow Oxygen Therapy Machine 70B Description High-flow nasal ...
Medical automatic 10-70L/Min high flow nasal cannula device 70C Description High Flow Nasal Cannula ...
Safe Airway Design 70L/min High Flow Oxygen Delivery System Description HFNC is a heated and ...
High Performance 7 Levels Temperature High Flow Nasal Cannula Device 70C Description HFNC is a ...
Micomme Medical 7Days Trend Review High Flow Nasal Cannula Device 70C Description A typical HFNC ...
Micomme Oxygen Therapy Solution S1 Description Application Advantages Specifications