Hunan Micomme Medical Technology Development Co., Ltd. |
|
Micomme medical heated humidified high flow nasal cannula oxygen
therapy device 60A
Description
HFNC is a simple system with clinical effects mainly dependent on
flow, oxygen concentration, and temperature setting.
HFNC is a promising novel oxygen delivery device, whose mechanisms
of action offer some beneficial effects over conventional oxygen
systems. It is considered to have a number of physiological
effects: it improves oxygenation, dynamic lung compliance,
homogeneity and end expiratory lung volume; it decreases anatomical
dead space and generates a positive airway pressure that can reduce
respiratory rate, the work of breathing, and enhance patient
comfort.
Application
HFNC has been used as a prophylactic tool or as a treatment device
mostly in patients with acute hypoxemic respiratory failure such as
pre-oxygenation before intubation, immunocompromised patients and
acute heart failure.
When HFNC is used to deliver oxygen, the flow rates are much higher
than can be achieved with traditional nasal cannula. This results
in a greater delivery of prescribed oxygen into the lungs, and less
entrainment of room air. The oxygen you want to deliver to your
patients is not prone to the same effect of dilution!
Advantage
During the pandemic, micomme provided over 7000 units of devices
globally.
At present, micomme occupies over 50% market share in high flow
filed in China.
Intelligent water-controlling system, automatically refills and
maintains the optimal water level in the water chamber.
The machine uses timing function, which is convenient for nurses to
charge by time.
Disposable heated tube and water chamber.
Specifications
Model | OH-60A | ||
Oxygen Adjustment | Setting | Manual | |
Range | 21%-100% | ||
| Low flow mode | 2-25L/min | |
High flow mode | 10-60L/min | ||
Temperature settings | 31℃,34℃,37℃ | ||
Real time monitoring parameters | Flow, FiO2, Temperature, Treatment time | ||
| Trend review | 1,3,7 days review | |
Content of review | Flow, FiO2, Temperature, Treatment time | ||
Presetting of treatment time | Yes | ||
| Auto reminder of maintenance | Yes | |
Main device disinfection | No need disinfection for circuits system | ||
Screen | 4.3 inches | ||
Dimension | 340*228*162mm | ||
Weight | 3.3kg | ||
| Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm |