Home Companies Hunan Micomme Medical Technology Development Co., Ltd.

ST-30K 300L/Min Non Invasive Ventilator Machine In ICU

Hunan Micomme Medical Technology Development Co., Ltd.
Active Member

Contact Us

[China] country

Address: 8, Lujing Road, High- Tech Zone, Yuelu Changsha, China

Contact name:Ellen He

Inquir Now

Hunan Micomme Medical Technology Development Co., Ltd.

ST-30K 300L/Min Non Invasive Ventilator Machine In ICU

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION for HOSPITAL USE

 

Description

 

Noninvasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy. NIV delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.

 

Noninvasive ventilation supports the patient by delivering the right inspiratory and expiratory pressures or tidal volumes to support their individual ventilatory demand, enhancing alveolar minute ventilation and recruiting collapsed alveoli.

 

 

Application

 

Better chance of survival: A meta-analysis suggested that NIV improved survival in acute care settings – and that it is more beneficial when applied earlier rather than as a rescue therapy.

 

Fewer complications: NIV reduces the number of possible complications by 62% and treatment errors by 50%.

 

Shorter stay in ICU: NIV shortens ICU stay and reduces the length of hospital stay by an average of 3 days.

 

Reduced risk of infection: The use of NIV instead of mechanical ventilation is associated with a lower risk of nosocomial infections. A study has shown significantly more infectious complications related to the presence of the endotracheal tube.

 

Advantage

 

HFNC (High Flow) mode, 21~100% FiO2, 31~40℃, 10~70L/min air oxygen mixture of humidified gas.

 

 6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.

 

The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.

 

Leakage compensation performance, the device offers 120 L/min maximum leakage compensation, it can also achieve a preset target pressure to form a pressure platform to complete accurate trigger and switch.

 

All equipment and consumables are developed and produced by Micomme with guaranteed performance, supply and after-sales service.

 

 

Specifications

 

ParameterST-30K
Ventilation modeS/T, CPAP, S, T, PC, VAT, HFNC
Oxygen concentration21%~100%, (increment by 1%)
Screen size5.7 Inch color screen
Waveform displayPressure/flow
IPAP4~40cm H2O
EPAP4~25cm H2O
CPAP4~20cm H2O
Target tidal volume20~2500mL
Backup BPM1~60BPM
Backup time0.2~4.0S
Rise time1~6 level
Ramp time0~60min
Ramp pressureCPAP mode: 4~20cm H2O Other mode: 4~25cm H2O
Pressure relief1~3 level
Spontaneous Timin0.2~4.0S
Spontaneous Timax0.2~4.0S
I-Trigger settingAuto, 1~3 level
E-Trigger settingAuto, 1~3 level
Trigger lockOff, 0.3~1.5S
Flow of HFNC mode10~70L/min
Max flow300L/min
Max leak compensation120L/min
Method of pressure measureThe pressure testing tube is on mask side
AlarmsApnea|Disconnection|Low minute volume|Low tidal volume|Power off|Over high pressure|Oxygen unavailable|Excessive oxygen pressure supply|Low oxygen pressure supply|Pressure tube off|Turbine dysfunction|Oxygen sensor failure|Air flow sensor failure|Low pressure|Low battery|Battery depleted
Apnea alarm range setting0S, 10S, 20S, 30S
Disconnection alarm range setting0S, 15S, 60S
Real-time monitoring dataPresent oxygen concentration|Oxygen source pressure|Pressure|Ventilation per min|Respiratory rate|Current leakage|Current volume|Trigger method
Other settingsScreen lock|Display brightness| Flow| Pressure| Waveform| Event summary
Backup battery8 hours

 

Hot Products

HIGH PERFORMANCE NON-INVASIVE SOLUTION WITH ST-30K Description Non-invasive ventilation (NIV) is ...
HIGH PERFORMANCE NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION for HOSPITAL USE Description ...
HIGH PERFORMANCE HOSPITAL NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION Description Non-invasive ...
HIGH PERFORMANCE HOSPITAL NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION Description Non-invasive ...
MICOMME HOSPITAL NON-INVASIVE VENTILATOR ST-30K with PERFECT COMBINATION of NIV and HFNC Description ...
HOSPITAL NON-INVASIVE VENTILATOR ST-30K with PERFECT COMBINATION of NIV and HFNC Description ...