Basic error | ±0.5% of the indicated value |
caliber (mm) | DN25~DN400 |
Explosion proof grade | Exia/de Ⅱ CT4 Ga/Gb |
flange | Comply with gb9119 standard, carbon steel (optional stainless
steel) |
Pressure class | DN25~DN400 1.0 1.6 2.5 4.0MPa The special pressure shall be determined through consultation with
the company |
Lining material | PTFE polytetrafluoroethylene, polyurethane rubber, PFA, F46,
natural rubber, neoprene, ETFE |
conductivity | ≥5μS/CM(Less than ≥ 5 μ S / cm negotiates the order with our
company ) |
electrode | 316L, Hastelloy, titanium, tantalum, platinum iridium alloy,
tungsten carbide |
Degree of protection | IP67 |
Medium temperature | -25℃~80℃ Split type up to 140 ℃ |
ambient temperature | -25℃~60℃ |
Influence of ambient temperature | <±0.1%/10℃or<±0.25%/10℃ |
Repeatability and repeatability | ≤±0.1%or±0.25% |
Analog output error | ≤±0.02mA |
Measuring range flow rate | ≤5m(Slurry) ≤20m/s(single medium ) |
Electrical connection | M20*1.5Sealing sleeve,G1/2,NPT1/2 |