Home Companies Qingdao Megatro Mechanical and Electrical Equipment Co., Ltd.

66KV single circuit two earth wire 0-30 self supporting lattice steel tower

Qingdao Megatro Mechanical and Electrical Equipment Co., Ltd.
Active Member

Contact Us

[China] country

Address: 288, Zhuhai Road, Huangdao district, Qingdao city, Shandong Province, China

Contact name:Cindy Wang (sale manager)

Inquir Now

Qingdao Megatro Mechanical and Electrical Equipment Co., Ltd.

66KV single circuit two earth wire 0-30 self supporting lattice steel tower

Country/Region china
City & Province qingdao shandong
Categories Other Chargers
InquireNow

Product Details

66KV single circuit two earth wire 0-30 self supporting lattice steel tower

This photo refers to our 66KV single circuit two earth wire 0-30 self supporting lattice steel tower. This type towers were widely used in overseas regions, which we had export to some east-south Asian countries, and Africa.

All the tower design data as follow:

Type

Self-Supporting lattice Steel Tension Tower

Nominal Voltage

66kV

Number of circuits

1

Conductor arrangement

Three Phase Horizontal single conductor, cap and pin insulator

Temperature range

0oC to 45oC

Cross arm Height

16m

Aerial earth arrangement

2 earth peaks

Type of aerial earth

2 x 7/1’’steel wire

Deviation

0 o -30o

Anchorage

Stub with cleats

Conductor type

AAAC  Tern

Scope of supply

All tower members, bolts, nuts washers, anti-climb device , anti-bird guard  , phase markers, number plates, tower earthing kits, lightning rod, and other  accessories

Maximum Wind

20~35m/s

Weight span

150~450m

Marking of tower members

According to client requirements

Bird Protection

Equipped with Anti – bird perch device on all phases

Anti –theft protection

Equipped with anti-theft bolts and anti-theft nuts from ground to anti0climb device

Galvanizing standard

GB

Design standard

According to client requirements

Steel standard

BS, ISO, GB

Design software

PLS

 

Our supply scope:

(A) Generating loading trees

(B) Generating Electrical Clearance and Structural Outline drawing.

(C) Structral Outline drawing will include Group Summary Table inserted in the drawing.

(D) Structural Outline drawing will include the critical base reactions to be used in design.

(E) A PLS-TOWER backup file for all necessary design runs will be included in the design submittal.

(F) Group summary output and Foundation Reactions output reports in Notepad format from PLS-TOWER design runs will be provided. The tables can also be provided in Excel format.

(G) All supplementary Excel spreadsheets developed for redundant member design and wind area calculations will be provided.

(H) Drafting & Detailing (if need)

(I) Tower Load Testing including test tower production (if need, but need pay test fees)

(J) Foundation Design (if need, but need design fees)

(K) Foundation Drawings (if need, but need design fees)

(L) Foundation and Stub settings (if need, but need design fees)

 

Since 2004, MEGATRO focus mainly international market and had export many kind of transmission structures to overseas clients. MEGATRO has been manufacturing lattice transmission tower & tapered steel poles for lighting, traffic control, communication and utility applications. MEGATRO pioneered the development of transmission tower, telecom tower, substation, and other steel structure and was also at the forefront in the design of Transmission tower.
 

Over 10 years of experience and innovation in engineering, designing and building towers has evolved MEGATRO into its current form:

l  Full Turn-Key provider including site acquisition, engineering services, manufacturing,   field services-DAS, tech services, value added reseller and monitoring, maintenance and network ownership

l  Specialize in developing supplying and building wireless and wired networks and in-building telecommunications systems, as well as energy infrastructure

l  Single source from Design to System Integration

l  Top quality, ISO 9001 registered

A complete selection of towers including self-support, lattice steel tower, monopoles and guyed towers, form custom-designed radar towers to broadcast towers and energy infrastructure. MEGATRO carries a variety of related products including fall protection, transmission lines, antennas, obstruction lights, and accessories, and other products if client need, MEGATRO also tailored product as per client condition.

MEGATRO mainly design all kinds of towers and posts for:

a.    Telecoms

b.    Power transmission

c.    TV and Radio Broadcast

d.    Roads and City Development

 

Our complete selection of towers includes:

a.    Self-supporting

b.    Monopoles

c.    Guyed towers

d.    Custom-designed radar towers

e.    Broadcast towers

f.      Power transmission

 

MEGATRO also designs and manufactures tower related products including:

a.    Fall protection

b.    Antenna brackets

c.    Other accessories if needed by clients


Today, with over 10 years of experience and our commitment to excellence, MEGATRO remains an industry leader in the manufacture and design of steel tubular & angular & monopole structures for all Highway, Municipal, Custom, telecom, lighting and electric Utility applications. MEGATRO has a complete staff of professional engineering personnel trained in the PLS Pole program and three different manufacturing processes for producing steel towers, poles and other supports. We utilize the latest versions of PLS-CADD, PLS-POLE, TOWER, AutoCAD and other CAD software.

 

For this 66KV single circuit two earth wire 0-30 self supporting lattice steel tower, we also consider below loads during design:

Normal loads
1 Dead weight load
2 Tension load
3 Erection load
4 wind load
 
Exceptional loads
1 Switching forces
2 short-circuit forces
3 Loss of conductor tension
4 Earthquake forces
 

 

Moreover, our MEGATRO is fully equipped and qualified to carry out Design Engineering services which includes:

√ Overhead Transmission line steel tower & Telecom steel tower

   Basic Design and Analysis

√ Shop Erection Drawings

√ As-Built Drawings

 

MEGATRO performs in-house design activities specializing in electrical overhead transmission &telecom tower steel works, which include wind and earthquake loading, static analysis, stress analysis by finite element methods and fatigue. Our Engineering Department is boasting of highly qualified engineering who are conversant with international codes and standards. The work is carried out with extensive use of CAE/CAD via a large of computer network. The computer hardware & drafting software are liked to the CNC workshop equipment for downloading of information thereby eliminating error and saving valuable production time.


For all tower and mast production, MEGATRO is one of the few manufactures who assemble a face of 66KV single circuit tower earth wire 0-30 self supporting lattice steel tower. This attention to quality may not be the cheapest process but it does insure every tower meets our high standards of quality. And it helps to reduce on-site construction cost due to mismatched assemblies. After fabrication all 66KV single circuit tower earth wire 0-30 self supporting lattice steel towers are delivered to the galvanizing facility to be Hot DIP Galvanized. Towers are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers. MEGATRO' 66KV single circuit tower earth wire 0-30 self supporting lattice steel towers systems can accommodate a variety of cross-arm. MEGATRO also offers a wide variety of accessories and mounts.

Other information:
Availability size: Based on the customer's requirements.
Material: Chinese material or as per clients requirement
Package: Both parties discuss before delivery
Port of Loading: Qingdao Port
Lead Time: One month or based on the customer's needs
Minimum order: 1 ton
Fabrication standard: Chinese Standard or other standard which client accepted

Steel grades
Tower legs: Chinese steel Q345B, which same to ASTM A572 GR50
Other webs, bracing and not stress plate and angle steel: Chinese Q235B, which same to ASTM A36
Plates: Chinese steel Q345B, which same to ASTM A572 GR50
Bolts: Chinese grade 6.8 and 8.8, which similar to ASTM A394
A) Dimension and tolerance for angle are according to GB/T1591-1994, similar to EN 10056-1/2
B) Hot dip galvanization in accordance with GB/T 13912-2002, which similar to ASTM A 123
C) The welding will be performance in accordance with AWS D1.1 or CWB standard

 

APPLICABLE STANDARD AND CODES

All towers manufactured and design shall be generally in accordance with latest revision of the following standards except where specifically directed otherwise.

General

IEC 60050 (151)                         International Electro-technical Vocabulary

                                       Part 51 Electrical and Magnetic Devices

IEC 60050 (601)                      Chapter 601: Generation, transmission and distribution of electricity-General

IEC 60050 (601)                    Chapter 601: Generation, transmission and distribution of electricity-Operation

IEC 60059                              IEC standard current ratings

Chinese Standard

No

Code

DESCRIPTION

1

GB/T2694-2003

Power Transmission line Steel tower - Technical requirements for manufacturing

2

JGJ81-2002

Technical specification for welding for steel structure of building

3

GB9787-88

Measuring and allowable tolerance for hot-rolled equal angle

4

GB709-88

Measuring and allowable tolerance for hot-rolled plate and strip

5

GB/T699-1999

Quality Carbon Structural Steel

6

GB/T1591-1994

Low alloy high strength structural Steel

7

GB700-88

Carbon Structural Steel

8

GB222-84

Method of sampling steel for determination of chemical composition and permissible variations

9

GB/T228-2002

Method for Tensile testing of metals

10

GB/T232-1999

Method for Bending test of metals

11

GB/T5117-1995

Carbon Welding Rod

12

GB/T5118-1995

Low Alloy Welding Rod

13

GB/T8110-1995

Welding wires for gas shielding arc welding of carbon and low alloy steels

14

GB/T10045-2001

Carbon steel flux cored electrodes for arc welding

15

JB/T7949-1999

Weld outer dimensions for steel construction

16

GB50205-2001

Test Standard for Acceptance of Steel Structure

17

GB/T470-1997

Zinc Ingot

18

GB3098.1-2000

Mechanical properties of fasteners-Part 1:Bolts, screws and studs

19

GB3098.2-2000

Mechanical properties of fasteners-Part2: Nuts, and thread

20

GB3098.3-2000

Mechanical properties of fasteners-Part3: Fastening screw

21

GB/T5780-2000

Helical Bolts Grade C

22

GB/T41-2000

Helical Nuts Grade C

23

GB/T90-2002

Flat Washer Grade C

24

GB/T13912-2002

Metal Coating, Technical Requirement and Test Method for Hot-dip galvanized Metal Parts

 

 

American Standards:

Standard

Description

ASTM A6/A6M

Standard specification for general requirements for rolled structural steel bars, plates, and sheet piling.

ASTM – 6   

-  General Requirements for delivery of Rolled Steel Plates, Shapes, sheet Piling Bars for  structural used

ASTM A36/A36-M-97a

Standard specification for Carbon structural steel

ASTM A123 / A123M-02

Standard specification for Zinc (Hot-Dip Galvanized) Coatings on iron and steel products

ASTM A143 / A143M-03

Standard Practise for Safeguarding Against Embitterment of Hot-Dip Galvanized Structural Steel Products and Procedure for Detecting Embitterment

ASTM A153/ A153M-05

Standard specification for zinc coating (Hot-Dip) on iron and steel hardware

ASTM A – 194 

-   Grade for bolt

ASTM A239

Standard practice for locating the thinnest spot in a zinc (Galvanized) Coating on Iron or Steel Articles

ASTM A242

Standard specification for High-Strength Low-Alloy Structural steel

ASTM A307

Standard Specification for Carbon Steel Bolts and Studs, 60000 PSI Tensile strength

ASTM A370-06

Standard Test Methods and Definitions for Mechanical Testing of Steel Products

ASTM A325

Standard Specification for structural bolts, steel, Heat treated 120/105 ksi minimum tensile strength

ASTM A-325 or A-354 

-  Galvanized hexagonal head of  connection bolt

ASTM A325-97

Standard Specification for High-strength Bolts for structural steel Joints

ASTM A384 / A384M-02

Standard Practise for Safeguarding Against Warpage and Distortion During Hot-Dip Galvanizing of Steel Assemblies.

ASTM A394-93

Standard Specification for steel Transmission Tower, Bolts, Zinc Coated and Bare

ASTMA – 563

-    Class and size of nuts

ASTMA – 572  

- Chemical composition of steel

ASTM A572/A572-97c

Standard specification for High-Strength Low-Alloy Columbium-Vanadium Structural steel

 ASTMA – 615 

-   The anchor bolt material

ASTM A673 / A673M-07

Standard Specification for Sampling Procedure for Impact  Testing of Structural Steel

ASTM B201

Standard practice for testing Chromatic coating on Zinc and Cadmium surfaces

ASTM  E94-93

Standard Guide for Radiographic Testing

ASTM E 709-95

Standard Guide for Magnetic Particle Examination

ASCE Manual 72   

-  Load testing a simple structure

ASCE 10-97

Standard Design of latticed steel transmission structures

AWS D1.1

American Welding Society D1,1/D1,1M structural Welding code- Steel

ANSI B-182-2

Bolts, nuts and washers dimensions

 

DIN VDE 0101                       -  Isokeraunic Level

VDE 0201                              - Climatic and environmental   conditions

CVDE 0210                           -  Minimum safety factors under    simultaneous working loads

ISO R898 Mechanical Properties of Fasteners

BS EN ISO 1461:1991 - High dip galvanized coatings on fabricated iron and steel articles. Specifications and standards

A) BS 5950: Welding Terms And Symbols

B) BS 729: Hot - Dip Galvanised Coating On Iron And Steel Articles

C) BS 2901: Filler Rods And Wires For Gas Shielded Arc Welding: Part 1 Ferritic Steels

D) BS 3692: ISO Metric Precision Hexagon Bolts, Screws And Nuts

E) BS 4360: Weldable Structural Steel

F ) BS 5135: Metal - Arc Welding Of Carbon And Carbon Manganese Steel

G) BS 5950: Part 1: Code Of Practice For Loading Latticed Tower & Masts

Part 2: Guide To The Background And Use Of Part 1"Code OF Practice For Loading"

Part 3: Strength Assessment of Members

H) DD 133 (1986): Code Of Practice For Loading Latticed Tower & Masts

I) BS 4592 (1987): Part 2: Specification For Expanded Metal Grating Panels

J) BS 4592 (1977): Code Of Practice For Protective Coating Of Iron And Steel Structure Against Corrosion

K) BS 4190: Bracing & Flanged Bolts

L) BS 4190: Rolled Steel sections, Flats & Plates

 

If any special requirement, we can design and discuss with client.

 

Hot Products

400KV DC TOWER For DC tower, there are only two phase conductors, whereas AC tower have three phase ...
400KV Four circuit transmission tower Four-circuit transmission line belong to multi circuit which ...
66KV single circuit two earth wire 0-30 self supporting lattice steel tower This photo refers to our ...
110KV four circuit angle tower Our company, QINGDAO MEGATRO HOLDING, CO., LIMITED, is a full service ...
11/22KV H type Intermediate pole Our company, QINGDAO MEGATRO HOLDING, CO., LIMITED, is a full ...
MEGATRO Box type overhead transmission steel tower These photos refer to our box type overhead ...