Shenzhen Huiertai Electronic Tech. Co., Ltd. |
|
Plastic / TPU Reusable ECG Lead Wires , Philips 5 Lead ECG Cable
1. Description
Nihon Kohden BR-004P Leadwire Set 5 Lead Ecg Cable With Snap Patient End with Low
profile, insert molded snap or pinch connectors offer patient comfort and secure attachment
to snap electrodes. The snap termination’s ergonomic, teardrop design reduces tangling at
the patient end connector. Grabber and mini clip terminations have dual sided metal contacts to provide the connection.
According to the different forms of the patient end connector ,divided into snap and clip 2 types | |||
Snap: | This kind of lead wire, the patient end connectors for the button/snap, the connector cover in the ecg electrodes. | ||
Clip: | This kind of lead wire, the patient end connectors for clip/graber,the connector clamp on the ecg electrodes. | ||
According to the different color code of the patient end connector, divided into European (IEC) and American(AHA) standard. | |||
AHA: | This kind of lead wire, the patient end connector coat color according to the American habit | ||
IEC: | This kind of lead wire, the patient end connector coat color according to the European habit |
2. Types
Brand | HET-Code | OEM P/N | Description of Goods |
Nihon Kohden | HM049 | BR-002P | Nihon Kohden BR-002P Leadwire set,3-lead |
HM050 | BR-004P | Nihon Kohden BR-004P Leadwire set,5-lead | |
HM051 | BR-019P | Nihon Kohden BR-019P Leadwire set,3-lead | |
HM052 | BR-021P | Nihon Kohden BR-021P Leadwire set,5-lead | |
HM053 | BR-546S | Nihon Kohden BR-546S Leadwire set,3-lead | |
PHOTO |
3. Specifications:
character: reusable |
material: plastic &TPU |
packing: 130mm*180mm |
colour: grey |
length: 0.85 metre |
standard: AHA, IEC, Snap, Clip |
HS No.: 8536901100 |
brand: Philips |
Condition & Terms: T/T 100% payment in advance, FOB Shenzhen |
Method of shipment: By air (via DHL, UPS, TNT, FedEX...), By sea |
Delivery lead time: 10 days upon receipt of payment |
Packing: Separate package, then in outer box |
Any require please do not hesitate to contact me on line, my MOB NO. is 0086-133 1668 2642 |
4. Process flow
1. Wire cutting -- 2. Stripping outer coating -- 3. Shield twisting
-- 4. Wire repair-- 5 .Sleeve crimping --
6. Open core --7. End pressing-- 8. Welding button -- 9. Internal
mold forming -- 10. Outer mold forming--
11. Test -- 12. Cable cutting --13. Stripping outer coating-- 14.
Shield twisting -- 15. Sleeve crimping --
16. Open core -- 17. Welding -- 18. Forming plugs of internal mold
-- 19. Forming plugs of internal mold --
20. Inspection of cable -- 21. Welding distributor -- 22. Internal
mold of distributor --
23. Outer mold of distributor -- 24. Test -- 25 .Visual inspection
-- 26.Package
5. Advantages
Lead wire without problems of short circuit, open circuit and poor contact.On resistance conforms to the conditions listed in the table below (with the exception of defibrillation circuit resistance), and allow the conduction resistance deviation + 20%.
Length of the cable | On resistance(max Ω) | ||
inch | mm | cuprum | alloy(eg.:Tin plated copper foil wire) |
1-36 | 25.4-914.4 | 1 | 50 |
37-84 | 939.8-2133.6 | 1.5 | 50 |
85-144 | 2159.0-3657.6 | 2 | 50 |
Various models of the promise of the lead resistance to see the table below(example one type
products):
product name | On resistance | Allowable deviation |
One-piece ECG cable,5-lead,6P,AHA,SNAP | ≤2Ω | +0.4Ω |
One-piece ECG cable,5-lead,6P,AHA,CLIP | ≤2Ω | +0.4Ω |
One-piece ECG cable,5-lead,6P,IEC,SNAP | ≤2Ω | +0.4Ω |
One-piece ECG cable,5-lead,6P,IEC,CLIP | ≤2Ω | +0.4Ω |
6. Picture Display