Urine ACE Acetaminophen Rapid Test 4mm Cassette , Cut - Off 400ng/Ml

City & Province ningbo zhejiang
Categories Other Chemicals
InquireNow

Product Details

Drug Abuse Test Kit Acetaminophen Rapid Test 4mm cassette ,high sensitivity cut-off 400ng/ml

 

Product Name

 

ACE (Acetaminophen) Rapid Diagnostic Test

Specimen: Urine

 

 

 

Intended Use

 

The ACE Rapid Test Cassette (Urine) is a rapid chromatographic immunoassay for the detection of Acetaminophen in human urine at a cut-off concentration of 5,000ng/mL. This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) or Liquid Chromatography/mass spectrometry (LC/MS) are the preferred confirmatory methods. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used

 

 

ParameterCalibratorCut-off (ng/mL)
ACEAcetaminophen5000

 

 

 

 

 

 

 

 

Test Principle

 

 

The ACE Rapid Test Cassette (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody. During testing, a urine specimen migrates upward by capillary action. Acetaminophen, if present in the urine specimen below 5,000ng/mL, will not saturate the binding sites of antibody-coated particles in the test. The antibody-coated particles will then be captured by immobilized Acetaminophen conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Acetaminophen level exceeds 5,000ng/mL because it will saturate all the binding sites of anti-Acetaminophen antibodies. A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration lower than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear in the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred

 

DIRECTIONS FOR USE

 

 

Bring tests, specimens, and/or controls to room temperature (15-30°C) before use.

Remove the test from its sealed pouch, and place it on a clean, level surface. Label the test with patient or control identification. For best results, the assay should be performed within one hour.

Using the provided disposable pipette, transfer 3 drops of specimen (approximately 120 µL) to the specimen well (S) of the device and start the timer.

Avoid trapping air bubbles in the specimen well (S), and do not add any solution to the result area.

As the test begins to work, color will migrate across the membrane.

Wait for the colored band(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 8 minutes

 

 

INTERPRETATION OF RESULTS

 

 

NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

 

 

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

 

 

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

 

 

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.

 

 

QUALITY CONTROL

 

A procedural control is included in the test. A colored line appearing in the control line region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique.

 

 

Analytical Sensitivity

 

A drug-free urine pool was spiked with ACE at the following concentrations: 0 ng/mL, 2500 ng/mL, 3750ng/mL, 5000ng/mL, 6250ng/mL, 7500ng/mL and 15000ng/mL.The result demonstrates >99% accuracy at 50% above and 50% below the cut-off concentration. The data are summarized below:

 

 

- ConcentrationPercent ofn  Visual Result
(ng/mL)Cut-off  Negative Positive
00%30 30 0
2500-50%30 30 0
3750-25%30 25 5
5000Cut-off30 15 15
6250+25%30 4 26
7500+50%30 0 30
150003X30 0 30

 

 

 

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry

Hot Products

Oral Drug Abuse Test kit ,Oral Drug Test midstream, High Accuracy, Easily & Quick operation, Gold ...
Drug Abuse Test Kit 6-MAM Rapid Test 4mm strip,cut-off 10ng/ml high sensitivity Product Name 6...
Drug Abuse Test Kit ABP (AB-PINACA) Rapid Test 4mm cassette ,high sensitivity cut-off 10ng/ml ...
Drug Abuse Test Kit ABP (AB-PINACA) Rapid Test 4mm Strip ,high sensitivity cut-off 10ng/ml Product ...
Drug Abuse Test Kit Acetaminophen Rapid Test 4mm cassette ,high sensitivity cut-off 400ng/ml Product ...
Drug Abuse Test Kit 6-MAM Rapid Test 4mm cassette ,high sensitivity cut-off 10ng/ml Product Name 6...