Home Companies Orient New Life Medical Co.,Ltd.

High Accuracy Home Blood Test Kit Detect Cholera Ag Antigen 5 Mins Reading Time

Orient New Life Medical Co.,Ltd.
Active Member

Contact Us

Address: 12F,Guting Building,Hefeng Creative Square,No.495 Jiangdong North Road,Ningbo,Zhejiang, China

Contact name:Jerry Meng

Inquir Now

Orient New Life Medical Co.,Ltd.

High Accuracy Home Blood Test Kit Detect Cholera Ag Antigen 5 Mins Reading Time

City & Province ningbo zhejiang
InquireNow

Product Details

One Step Cholera O1 & O139 Antigen Rapid Test Device , Certified, Whole Blood/Serum/Plasma Specimen,, quick and easily

 

Product Name: One Step Cholera O1 & O139 Antigen Rapid Test Device

 

Accessories:

 

Test cassettesPackage insert
Specimen collection tube with extraction buffer 


 

Intended Use:

 

The Cholera Ag Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection and differentiation of Vibrio Cholerae O139 antigen and O1 antigen in human fecal specimen. It is intended to be used by professionals as a screening test and as an aid in the diagnosis of infection with V. Cholerae. Any reactive specimen with the Cholera Ag Rapid Test must be confirmed with alternative testing method(s) and clinical findings.

 

Summary:

 

Cholera is an acute infectious disease that is characterized by massive loss of body fluids and electrolytes through severe diarrhea. The etiological agent of cholera has been identified as Vibrio cholerea (V. Cholerae), a gram negative bacterium, which is generally transmitted to humans via contaminated water and food.

 

The species V. Cholerae is divided into several serogroups on the basis of O antigens. The subgroups O1 and O139 are of special interest because both can cause epidemic and pandemic cholera. It is critical to determine as quickly as possible the presence of V. cholerae O1 and O139 in clinical specimens, water, and food so that appropriate monitoring and effective preventive measures can be undertaken by public health authorities.

 

The Cholera Ag Rapid Test can be used directly in the field by untrained or minimally skilled personnel and the result is available in less than 10 min, without cumbersome laboratory equipment.

 

Test Principle:

 

 

The Cholera Ag Rapid Test is a lateral flow chromatographic immunoassay. The test cassette consists of:

 

1) a burgundy colored conjugate pad containing monoclonal anti-V. Cholera O1 and O139 antibodies conjugated with colloid gold (O1/O139-antibody conjugates) and rabbit IgG-gold conjugates, 2) a nitrocellulose membrane strip containing two test band (1 and 139 bands) and a control band (C band). The 1 band is pre-coated with monoclonal anti-V. Cholera O1 antibody. The 139 band is pre-coated with monoclonal anti-V. Cholera O139 antibody. The C band is pre-coated with goat anti-mouse IgG antibody.

 

When an adequate volume of test specimen is applied into the sample well of the test cassette, the specimen migrates by capillary action across the cassette. V. Cholera O1/O139 antigen if present in the specimen will bind to the corresponding O1/O139-antibody gold conjugate. This immunocomplex is then captured on the membrane by the pre-coated anti-V. Cholera O1/O139 antibody, forming a burgundy colored test band, indicating a Cholera O1/O139 positive test result. Absence of the test band suggests a negative result.

 

The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti-mouse IgG/ mouse IgG-gold conjugate regardless of the color development on the test band. Otherwise, the test result is invalid and the specimen must be retested with another device.

 

 

SPECIMEN COLLETION

 

Consider any materials of human origin as infectious and handle them using standard biosafety procedures.

 

  1. Collect a random sample of feces into a clean container.
  2. Unscrew the cap of the Sample Extraction tube and remove the applicator stick.
  3. Insert the stick into the fecal specimen in at least five different sites. Be sure sample contacts the inside grooves.
  4. Replace the stick in the tube and tighten the cap securely. For a liquid stool, take 0.3 ml with a plastic pipette and then place the sample into the Sample Extraction tube.

 

 

 

INTERPRETATION OF RESULTS

 

POSITIVE:* Two lines appear. One colored line should be in the control line region (C) and another apparent colored line should be in the test line region (T).

 

 

NEGATIVE: One colored line appears in the control line region (C). No line appears in the test line region (T).

 

INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 
ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry

 

Hot Products

Filariasis IgG/IgM Infectious Disease Blood Tests, 4mm cassette, with buffer Intended Use: The ...
4mm cassette Mycoplasma pneumoniae Antigen Rapid Diagnostic test , quickly and easily, gold ...
High Accuracy HCV Rapid Diagnostic test 4mm Cassette, detecting Hepatitis C virus antibody easily ...
One Step Giardia lamblia Antigen Rapid Test, Feces specimen,gold colloidal method, easily and quick ...
One Step Cholera O1 & O139 Antigen Rapid Test Device , Certified, Whole Blood/Serum/Plasma Specimen,...
One Step HAV(hepatitis A virus) IgM Rapid , to detect hepatitis A virus acute break,gold colloidal ...