Product Description
Type:

Suit for Alfa Laval LKH Series Pumps with

Flushed Seal Chamber and PTFE Lip Seal

 

 

 

 

 

Technical Parameters

 

 

Temperature-30℃~+200℃
pressure≤1.2Mp a
Speed≤10m/s
Mediumwater

 

Materials

 

Rotary Ring

SiC/VIT

Stationary Ring

SiC/VIT

SpringSUS304/SUS316
Stationary SeatSUS304/SUS316
Secondary Seal

 VITON/EPDM

Rotary Ring HolderSUS304/SUS316

 

 

Preperation:
1. Shaft Outside Diameter is within tolerance +-0.05mm
2. Shaft run out <0.1mm
3. Shaf end float <0.13mm
4, No sharp edges on the shaft over the o ring


Note:
During the installation,don't scratch or damage the o ring.lf anything is damaged,please contactwith Us to replace a new one.


Installation in strucstions:
1. The full set of cartridge seal is cleaned and exactly passed leakage examine before sale.Inorder to avoid damage,don't disassemble and clean the parts again before fixing.

 

2 The fitting allowance between the seal and shaft is dl h6 0.8,and there should be leading-inedge at the end of shaft.The outside diameter of shaft at the position of screw should be 01 0.2mm smaller,resisting the screw over-tighten.Lubricate the shaft with oil

 

3. Place the cartridge seal into the pump chamber,then:
A: Tighter four screw bolts of flanges,ensuring the medium leading in hole"G"at the top Position

B : Tighter four set screws and position the shaft sleeve on the shaft.
C: Remove four gauge plates.Please keep them and they wil be used in future installation and
disassemble.
D: Connect the medium lead_in pipe with hole"G"in order to flush away the friction heat and
flushing the seal chamber when pump running.


Note:
ter complete the installation,turning the shaft by hand to check for the rotationi he shat could not rotate smoothily,seal had been improperly installed.

 

 

 

We would like lo sincerely ooperale with Clients to supply high qually products and senice We beleve in establishing a long:erm cooperalive relalionshipis lhe key to suceess

 

Hot Products

Blackmer pump mechanical seal for pump Blackmer X,GX,TX3 1. YM BLK is for GX & X3" pumps Used in ...
Single Mechanical Seals to suit SRU (SSP SR) & NMOG Range. Double Mechanical Seal version available ...
Temperature -30ºC to 200ºC, dependent on the elastomer Pressure Up to 10 bar Speed Up to 15 m/s End ...
1.YUEMI P07 is equal to AS-92D for GM,ALC,LKHpumpal to And our seal can replace the original one. 2. ...
Product Description Type: Suit for Alfa Laval LKH Series Pumps with Flushed Seal Chamber and PTFE ...
Due to the diversity of mechanical seal structural forms, when selecting the mechanical seal ...