Home Companies Hangzhou Kaihong Membrane Technology Co., Ltd.

4 Inch PVDF Hollow Fiber MBR Ultrafiltration Membrane For Water Purification 0.03um

Hangzhou Kaihong Membrane Technology Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Bldg 10-1, # 11 Lingang Rd, Renhe Street, Yuhang Dist, Hangzhou, China

Contact name:Tony Zhang

Inquir Now

Hangzhou Kaihong Membrane Technology Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

4 Inch PVDF Hollow Fiber MBR Ultrafiltration Membrane For Water Purification 0.03um

Country/Region china
City & Province hangzhou
Categories Water Treatment
InquireNow

Product Details

4 inch Ultra-filtration Membrane Module for Pure Water Purification with PVDF material

 

 

Ultra-filtration is an advanced technology to separate, purify and concentrate substance . It presents hollow capillary tube shape or hollow fiber shape, micro-pore covers tube wall densely. Feed liquid is flowing in or out the membrane under the influence of pressure, dissolvent or small molecule can permeate membrane and become pure liquid by collection, while large molecule (such as protein, each kind of enzyme, nucleic acid, polysaccharide and so on) ,colloid particle (such as emulsion, micro-ion) and bacterium are cut off by the membrane and are taken off by the circulating liquid flow to become concentrating liquid. waters.

UF provide:
* High and consistent product quality measured by turbidity (NTU) or silt density index (SDI).
* Tolerance to feedwater quality upsets.
* No use of pretreatment chemicals (polymer, coagulant, pH adjustment) and associated costs for sludge disposal.
* Small footprint and less weight than media filters.

 

2.2 Structure and Specifications of UF Membrane Modules

2.2.1 Small size of UF modules

aa.png

 

 

 

Size and weight

 

ModelKH-UF-4040W-PVDFKH-UF-6040W-PVDF
Module Diameter ( A, mm)Φ90 mmΦ160 mm
Module Length ( B, mm)960mm960mm
Module Length (C, mm)1106 mm1304 mm
Size of Inlet/Outlet (D, mm)DN25DN32
Operating TypeOutside to InsideOutside to Inside
Membrane Area8.0 m220 m2
Dry weight of the module5 Kg12 Kg

 

 

 

 

 

Parameters

Shell materialUPVCUPVC
Membrane MaterialPVDFPVDF
Membrane pore size0.03μm0.03μm
Inner diameter of the hollow fiber0.7 mm0.7 mm
Outer diameter of the hollow fiber1.3mm1.3mm
Turbidity of Permeating water≤ 0.2NTU≤ 0.2 NTU

SDI value of permeating water

 

≤ 3≤ 3

Flux rate of purified water

(0.10MP,20℃)

≥1000L/H≥3000L/H

 

 

 

 

Typical Process

 

Temperature Range5-45 ℃5-45 ℃
PH Value Range2-132-13

Permeating Flux rate for different

Water

40 - 80 l/m2/hr40 -80 l/m2/hr
Operating Pressure≤0.12 MPa≤0.12MPa
Maximum Inlet Pressure0.2 MPa0.2MPa
Backwashing flux rate

1.5-2.0 times of

Permeating Flux

1.5-2.0 times of

Permeating Flux

Backwashing timesOnce per 30-120 minutesOnce per 30-120 minutes
Chemical cleaning online during backwashingOnce per 7-14 daysOnce per 7-14 days


The structure as the following:2.2.2 type A of 8 inches UF module.

ab.png

 

 

 

Size and weight

 

ModelKH-UF-8040W-PVDFKH-UF-8060W-PVDF
Module Diameter ( A, mm)Φ200 mmΦ200 mm
Module Length ( B, mm)1220 mm1640 mm
Module Length (C, mm)1365 mm1785 mm
Size of Inlet/OutletDN50DN50
Operating TypeOutside to InsideOutside to Inside
Membrane Area30 m245 m2
Dry weight of the module20 Kg35 Kg

 

 

 

 

 

Parameters

Shell materialUPVCUPVC
Membrane MaterialPVDFPVDF
Membrane pore size0.03μm0.03μm
Inner diameter of the hollow fiber0.7 mm0.7 mm
Outer diameter of the hollow fiber1.3mm1.3mm
Turbidity of Permeating water≤ 0.2NTU≤ 0.2 NTU

SDI value of permeating water

 

≤ 3≤ 3

Flux rate for of purified water

(0.10MP,20℃)

≥ 3600L/H≥ 5400L/H

 

 

 

 

Typical Process

 

Temperature Range5-45 ℃5-45 ℃
PH Value Range2-132-13

Permeating Flux rate for different

Water

40 - 80 l/m2/hr40 -80 l/m2/hr
Operating Pressure≤0.12 MPa≤0.12MPa
Maximum Inlet Pressure0.2 MPa0.2MPa
Backwashing flux rate

1.5-2.0 times of

Permeating Flux

1.5-2.0 times of

Permeating Flux

Backwashing timesOnce per 30-120 minutesOnce per 30-120 minutes
Chemical cleaning online during backwashingOnce per 7-14 daysOnce per 7-14 days


2.2.3 type B of 8 inches UF module. The structure as the following:

ac.png

 

 

 

 

Size and weight

 

ModelKH-UF-SFX2860-PVDFKH-UF-SFX2880-PVDF
Module Diameter (OD, mm)Φ225 mmΦ225 mm
Module Length ( L1, mm)1500 mm2000 mm
Module Length (L2, mm)1630 mm2130 mm
Module Length (L3, mm)1820 mm2320 mm
Module Length (L , mm)1860 mm2360 mm
Operating TypeOutside to InsideOutside to Inside
Membrane Area52 m277 m2
Dry weight of the module42 Kg62 Kg

 

 

 

 

 

Parameters

Shell materialUPVCUPVC
Membrane MaterialPVDFPVDF
Membrane pore size0.03μm0.03μm
Inner diameter of the hollow fiber0.7 mm0.7 mm
Outer diameter of the hollow fiber1.3mm1.3mm
Turbidity of Permeating water≤ 0.2NTU≤ 0.2 NTU

SDI value of permeating water

 

≤ 3≤ 3

Flux rate of purified water

(0.10MP,20℃)

≥ 6500L/H≥ 8000L/H

 

 

 

 

Typical Process

 

Temperature Range5-45 ℃5-45 ℃
PH Value Range2-132-13

Permeating Flux rate for different

Water

40 - 80 l/m2/hr40 -80 l/m2/hr
Operating Pressure≤0.12 MPa≤0.12MPa
Maximum Inlet Pressure0.2 MPa0.2MPa
Backwashing flux rate

1.5-2.0 times of

Permeating Flux

1.5-2.0 times of

Permeating Flux

Backwashing timesOnce per 30-120 minutesOnce per 30-120 minutes
Chemical cleaning online during backwashingOnce per 7-14 daysOnce per 7-14 days


The whole installation and application process of our MBR modules are described as the following photo:

 

 

 

A.OEM service available for ro membrane?

Yes, OEM service is available,

 

B.Payment Term

We can accept L/C, T/T, Western Union, MoneyGram

 

C.Certicification

We had passed ISO9001

 

D.Shipping

If your order is not big enough , Door to Door Service is the best choice via UPS,FEDEX,DHL,EMS.

For big quantity, by air or by sea through your forwarder is one Normal Way , we also can provide cost-effective forwarder for your reference.

 

E. Lead time

The normal lead time is 7-15 days, which depends on your quantities.

 

Hot Products

Hollow Fiber MBR Membrane for Wastewater Treatment with PVDF material Membrane Bio Reactor (MBR) It ...
4 inch Ultra-filtration Membrane Module for Pure Water Purification with PVDF material Ultra...
MBR Membrane Elements for Wastewater Treatment with PVDF material 1. MBR Introduction MBR System is ...
2100m2 Industrial Wastewater Biochemical Treatment MBR Membrane with PVDF 0.05 pore size 1. MBR ...
Domestic Wastewater Biochemical Treatment MBR Membrane with PVDF 0.05 pore size 1. MBR Introduction ...
Domestic Wastewater Treatment MBR Membrane Module with PVDF 0.05 pore size 1. MBR Introduction 1...