WUXI Hai Roll Fone Science&Technology Co.,Ltd |
|
Fully Automatic N95 Mask Making Machine For Disposable Non Woven Face Mask
Equipment Introduction
This equipment realizes the automatic production of flat earloop masks, including the production processes of feeding, folding and pressing, nose bridge tendon feeding, mask forming, earloop welding, finished product cutting and etc.
The output masks are comfortable to wear without pressure, and can be used in different scenarios like factory production, hospital medical treatment, building construction, daily life and etc.
Medical Flat Mask Production Raw Material
Anti-filter meltdown cloth:
Gram weight: ≥20g/ m²(≥22g/ m² is advised)
Filter efficiency: KN90,KN95, KN100 or BFE95/BFE 99 standard(Medical use)
Coil:ID40- 85mm, OD 600mm, Max. OD 700mm,Width175mm.
Nonwoven:
Mask inner & outer material
Gram weight: 25-30g/ m²,
Color: blue and white.
Coil:ID 40- 85mm, OD 600m,Max. OD 700mm,
Blue color width 175mm, white color width195mm
Earloop:
Elastic nonwoven
Thread diameter: 2.5-3.5mm (hollow), ultrasonic welding to mask available
Plastic aluminum nose strip:
Single core3. 0* 0. 5mm.
Automatically seamed into the mask.
Coil:ID>152mm, OD≤450mm, Height<72mm.
Product parameters
Dimension | 7850mm(L) X3600mm(W) X2000mm(H) |
Color | warm grey + silver white |
International standard warm grey 1C | |
Weight | ≤5000kg, ground weight capacity ≤500kg/m2 |
Working power | equipment 220VAC±5%; 50HZ;rated power 12KW |
Working air pressure | Compressed air pressure 0.5-0.8MPa; compressed air flux 300L/min |
Production efficiency | 100-110PPM(based on 20 hours each day, daily capacity about |
120,000-140,000 pieces) | |
Qualification ratio | 99%(excluding unqualified incoming materials, improper operation by |
employees) | |
Equip failure ratio | ≤2%(equipment failure itself) |
Operating environment | Temperature 10 一 35℃; humidity: 5-35%HR |
No flammable, corrosive gas, no dust (cleanliness no less than 100,000grade) |
Ambience:
Temperature: 10- 35°C ;
Humidity: 5-35%HR;
No flammable, corrosive gas, no dust (cleanliness no less than 100,000 grade)
Max. permissible dustiness, unit/m² | Max. permissible microbes | |||
Cleanliness level | ≥0.5 um | ≥5 um | Sediment bacteria | Floating bacteria |
unit/vessel | unit/m3 | |||
100 grade | 3,500 | 0 | 1 | 5 |
10,000 grade | 350,000 | 2,000 | 3 | 100 |
100,000 grade | 3,500,000 | 20,000 | 10 | 500 |
300,000 grade | 10,500,000 | ≤60,000 | 15 | |
Power requirement
Working power:220VAC 土 5%, 50HZ.
Rated power:12KW(excluding air compressor power).