316SS Stainless Electromagnetic Flow Meter Sensor Magnetic Flowmeter

 

Application:

Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.

Features:

1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.

2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.

3. On-site modification of the measuring range available.

4. LCD display, easy to use and simple to operate.

5. Using SMD devices and SMT technology.

6. Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.

7. Anti-interference, reliability, measurement range up to 150:1.

8. Ultra low EMI switch, wide range of power supply voltage.

9. RS485, RS232, Hart and Modbus digital communication signal output.

10. Self-checking function.

Technical parameters:

PTFE Lined Pipe

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600

Rubber Lined Pipe

40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized

Flow direction

positive and negative, net flows Turndown

Measuring range ratio

150:1

Repeatability error

+/-0.1%

Accuracy

piped: 0.5 class, 1.0 class

Measured medium temperature

Common rubber lining: -20~+60 ° c

High temperature rubber lining: -20~+90 ° c

PTFE lining: -30~+100 ° c

High temperature vinyl lining: -30~+180 ° c

Rated working pressure

pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

DN200~DN1200: ≤ 1.0MPa

Flow measuring range

flow measuring range corresponding to flow rate range is 0.3~15m/s

Measured fluid conductivity

5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)

Output

Current:4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA

Load resistance

< 600 Ω

Electrode material

316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials

Protection grade

standard: IP65; IP68

Working power supply

85~265VAC 45~63HZ

Straight pipe length

pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN

Connections

flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements.

Explosion-proof mark

mdllBT4

environment temperature

-25 ° c ~=60 ° c

Relative humidity

5%~95%

Total power consumption

<20W

Sichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-working and truth-seeking characters. Solid foundation has been established.

In 2017, we moved into our new factory whhich occupies the area about 20000 square meter, the workshop of 6900 square meter, R&D department of 1180 square meter, integrated office building of 1260 square meter, and we have established the high accuracy flow calibration lines.

 

Certificate and Packaging

 

Electromagnetic flowmeter maintenance and installation precautions
1. Routine maintenance
Visually inspect the instrument for periodic inspection, check the surrounding environment of the instrument, remove dust, ensure that there is no other substance in the water, check whether the wiring is good, check whether there is a new strong electromagnetic field device near the instrument or a new cable meter. If the measuring medium is easy to contaminate the electrode or precipitate or scale in the measuring tube wall, it should be regularly cleaned and cleaned.

2. Fault finding
After the flowmeter starts to be put into operation or is put into operation for a period of time, it is found that the instrument is not working properly. You should first check the external condition of the flowmeter, such as whether the power supply is good, whether the pipeline is leaking or is in a non-full-tube state, and there are air bubbles in the pipeline. Whether the signal cable is damaged or not, and whether the converter output signal (ie, the rear instrument input circuit) is open. Remember to blindly disassemble the flowmeter.

3. Sensor inspection
Test equipment: one 500MΩ insulation resistance tester, one multimeter.

 

Hot Products

316SS Stainless Electromagnetic Flow Meter Sensor Magnetic Flowmeter Application: Due to its unique ...
Flow Rate LCD Display Fischer Porter Electromagnetic Flow Meter Application: Due to its unique ...
PN16-PN63 MAG Electromagnetic Flow Transmitter Sensor Battery Powered Electromagnetic flow meters ...
4-20mA Electromagnetic Flow Meter For Petroleum , Chemical Engineering Product Description ...
DN10~DN2200 Electromagnetic Water Flow Meter Fully Welded Electromagnetic Water Flow Meter ...
IP65 Waterproof Electromagnetic Flow Meter Stainless Steel Chamber Electromagnetic Flow Meter ...