Magnetic level gauge electrical signal is implemented by a combination of remote and basic level remote device. Level remote device by the UR-type resistance sensors and UB type R / I converter modules, the transmitter sensor in the form of bundled fixed to the outside of the main conduit UHZ type level gauge magnetic flap so that it is level count the same magnetic coupling system. When the magnetic float moves up and down with the liquid level, the level corresponding to the position of the reed that is the role of the magnetic field inside the float pull resistor chain resistance to change by switching module will change the resistance signal into a standard two-wire 4 ~ 20mADC output signal, the signal can be easily and III-type electric instrument, display instrument supporting the use, can also be indicative of the light beam, the digital display regulator supporting the use of alarm, so as to display, control, regulation and alarm purposes.
Product Parameters
(1) Center-center distance: | 150~6000mm |
(2) Medium density: | More than 0.45g/cm3 |
(3) Nominal pressure: | PN2.5~PN40, PN40~PN320(x 0.1MPa) |
(4) Material: | SS304, 316L, PP, PTFE, or customized |
(5)Operating temperature: | -190 ~ +425 °C |
(6) Process connection: | DN20~DN80/RF/14,DN80~DN250/RF/14 |
(7)Indicator types: | |
A: Al &ABS flap cylinder | B: Al flap plate |
C: PVC ABS flap cylinder | D: PP&ABS flap cylinder |
E: AL &LED | F: PP&LED |
(10)Protection class: | IP65 |
Workshop and Procesing
The appearance of the magnetic flap level gauge. The magnetic flap
level gauge can achieve high sealing, prevent leakage, and can
perform safe and reliable liquid level measurement under high
temperature, high pressure, high viscosity, and strong corrosion
conditions. The whole process has no blind areas, conspicuous
display, intuitive readings, wide measurement range, equipped with
a liquid level alarm control switch, which realizes the upper and
lower limit alarm control of the liquid level or boundary position,
and is equipped with a liquid level transmitter, and the liquid
level boundary signal can be converted into Two-wire 4-20 mADC
standard signal to realize remote detection, display, recording and
control.
What is the working principle of the magnetic flap level gauge? An
instrument that uses a floating sub-magnet to drive the flip of a
two-color sheet to indicate the liquid level. The magnetic float in
the main body of the magnetic flap level gauge moves up and down
with the rise and fall of the liquid level, and at the same time
drives the two-color sheet in the display outside the main body to
turn over. When there is a liquid level, it turns red, and when
there is no liquid level, it turns white. The dividing line between
the red and white* bands represents the horizontal height. There is
a striking scale ruler on the left side of the indicator. In this
way, the liquid level display becomes clearer.