316S Stainless Steel Electromagnetic Flow Meter Hydrology Open Channel Electromagnetic Flow Meter

Electromagnetic flowmeter as an effectively measure the volume flow rate of conductive media, its main components include sensors, flow conversion and processing instruments. And its main feature is that it has no throttling flow-resisting parts, it is not easy to block, has good corrosion resistance, and has a wide range of applicable media. The measurement accuracy is not affected by physical parameters such as temperature, viscosity, density, pressure, and specific gravity of the measured medium. A certain conductivity range is independent of the type of liquid being calibrated.

As a most widely used flow instrument, electromagnetic flowmeters are commonly used to measure conductive liquids such as tap water, sewage, and seawater. Therefore, after running for a period of time, it is easy to contaminate the electrode or to precipitate and foul in the measurement tube wall. So the adhered scale layer in the measuring tube of the electromagnetic flowmeter should be removed in time, otherwise the instrument may not work properly.

Application

Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.

Features:

1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.

2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.

3. On-site modification of the measuring range available.

4. LCD display, easy to use and simple to operate.

5. Using SMD devices and SMT technology.

6. Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.

7. Anti-interference, reliability, measurement range up to 150:1.

8. Ultra low EMI switch, wide range of power supply voltage.

9. RS485, RS232, Hart and Modbus digital communication signal output.

10. Self-checking function.

 

Technical parameters

PTFE Lined Pipe

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600

Rubber Lined Pipe

40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized

Flow direction

positive and negative, net flows Turndown

Measuring range ratio

150:1

Repeatability error

+/-0.1%

Accuracy

piped: 0.5 class, 1.0 class

Measured medium temperature

Common rubber lining: -20~+60 ° c

High temperature rubber lining: -20~+90 ° c

PTFE lining: -30~+100 ° c

High temperature vinyl lining: -30~+180 ° c

Rated working pressure

pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

DN200~DN1200: ≤ 1.0MPa

Flow measuring range

flow measuring range corresponding to flow rate range is 0.3~15m/s

Measured fluid conductivity

5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)

Output

Current:4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA

Load resistance

< 600 Ω

Electrode material

316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials

Protection grade

standard: IP65; IP68

Working power supply

85~265VAC 45~63HZ

Straight pipe length

pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN

Connections

flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements.

Explosion-proof mark

mdllBT4

environment temperature

-25 ° c ~=60 ° c

Relative humidity

5%~95%

Total power consumption

<20W

Hot Products

HKLD 4-20mA Integrated Electromagnetic Type Flow Meter 18 Month Warranty Product Description HKLD ...
PTFE Liner Electromagnetic Flow Meter Flange Connection For Measure Product Description HKLD ...
Industry 4-20 ma integrated magnetic flow meter facory with HART Product Description HKLD intelligen...
Stainless Steel Electromagnetic Flow Meter With Self Checking Function Product Description HKLD type ...
316S Stainless Steel Electromagnetic Flow Meter Hydrology Open Channel Electromagnetic Flow Meter ...
Dn1600 Insertion Water Sewage Electromagnetic Flow Meter 2 Inch 4800e Carbon The electromagnetic ...