Product Description
HKLD intelligent electromagnetic flowmeter is a kind of fully intelligent electromagnetic flowmeter developed by our company with advanced technology at home and abroad. Its Chinese electromagnetic converter core uses high-speed central processing unit. The calculation speed is very fast, the accuracy is high, and the measurement performance is reliable. The circuit design of the converter adopts international advanced technology, the input impedance is up to 10 ohms, the CMRR is better than 100db, and the rejection ability for external interference and 60Hz/50Hz interference is better than 90db. It can measure the flow rate of fluid medium with lower conductivity.

Product features

1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.

2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.

3. On-site modification of the measuring range available.

4. LCD display, easy to use and simple to operate.

5. Using SMD devices and SMT technology.

6. Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.

7. Anti-interference, reliability, measurement range up to 150:1.

8. Ultra low EMI switch, wide range of power supply voltage.

9. RS485, RS232, Hart and Modbus digital communication signal output.

10. Self-checking function.

 

Application

Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.

 

Product Parameters

(1)working pressure:pipeline: DN10~DN65: ≤ 2.5MPa
(2)Chamber Material:Stainless steel, carbon steel
(3)Power Supply:85~265VAC 45~63HZ
(4)Repeatability Accuracy:+/-0.1%
(5)Pipe Size:DN10~DN1200
(6)Output current:4~20mADC
(7)Accuracy:piped: 0.5 class, 1.0 class
(8)Warranty:20 months
(9)Life:5-7 years
(10)Measuring range ratio:150:1

 

Detailed Images

 

HKLD type intelligent electromagnetic flowmeter is a fully intelligent electromagnetic flowmeter developed by our company using the most advanced technology at home and abroad. Its electromagnetic converter core adopts high-speed central processing unit. The calculation speed is very fast, the precision is high, and the measurement performance is reliable. The sensor adopts non-uniform magnetic field technology and special magnetic circuit structure, the magnetic field is stable and reliable, and the volume is greatly reduced, the weight is reduced, and the flowmeter is characterized by small flow.

Application:

Product Parameters

Product NameElectromagnetic Flowmeter
Repeatability error+/-0.1%
Accuracy class0.5 class, 1.0 class
Measured medium temperatureCommon rubber lining: -20~+60 ° c
High temperature rubber lining: -20~+90 ° c
PTFE lining: -30~+100 ° c
High temperature vinyl lining: -30~+180 ° c
Rated working pressure

pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

DN200~DN1200: ≤ 1.0MPa

Flow rate range0.3~15m/s
Measured fluid conductivity≥5μs/cm liquid
Output4~20mA / 4~20mA + Hart
Electrode material

316L, titanium (Ti), tantalum (Ta), Hastelloy (H), Platinum (Pt) or

other special electrode materials

Working power supply85~265VAC / 24VDC / Battery
Straight pipe lengthpipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN
ConnectionsFlange
Protection gradestandard: IP65; IP68(optional)
Explosion-proof markmdllBT4

Remote Insertion Alarm Magnetic Flow Meter With Flange Connection

Sichuan VACORDA Instruments Manufacturing Co., Ltd.is a professional production-manufacturing enterprise specialized in designing, producing and marketing of instruments and apparatuses. Our company has been established for 23 years since 1997 to grow up to be a team of high-quality, united, hard-working and truth-seeking characters. Solid foundation has been established.

 

In 2017, we moved into our new factory whhich occupies the area about 20000 square meter, the workshop of 6900 square meter, R&D department of 1180 square meter, integrated office building of 1260 square meter, and we have established the high accuracy flow calibration lines.

 

Precautions

(1) Before installing the turbine flow meter, clean the piping. When the measured media is unclean, add a filter. Otherwise, the turbine and bearing are easily stuck and no flow can be measured.

(2) When disassembling the flowmeter, the magnetic induction part cannot be collided.

(3) Set the meter factor before commissioning. Carefully check to make sure that the instrument wiring is correct and the grounding is good before sending power.

(4) When installing the turbine flowmeter, the front and rear duct flanges should be horizontal, otherwise the pipeline stress has a great influence on the flowmeter.

 

Test steps
(1) In the case where the pipe is filled with medium, use a multimeter to measure the resistance between terminals A, B and C. The resistance between A-C and B-C should be equal. If the difference is more than 1 time, there may be leakage of the electrode, condensation on the outer wall of the measuring tube or inside the junction box.
(2) Under the condition of lining drying, the insulation resistance between A-C and B-C (should be greater than 200 MΩ) is measured by MΩ meter. Then use a multimeter to measure the resistance of the two electrodes in terminals A and B and the measuring tube (should be in short-circuit communication). If the insulation resistance is small, indicating that the electrode is leaking, the entire flowmeter should be returned to the factory for repair. If the insulation is reduced but there is still more than 50 MΩ and the inspection result of step (1) is normal, it may be that the outer wall of the measuring tube is damp, and the inside of the outer casing can be dried by a hot air blower.
(3) Use a multimeter to measure the resistance between X and Y. If it exceeds 200 Ω, the excitation coil and its lead wire may open or contact poorly. Remove the terminal block check.
(4) Check the insulation resistance between X, Y and C, which should be above 200 MΩ. If it is lowered, use hot air to dry the inside of the casing. In actual operation, the decrease in the insulation of the coil causes the measurement error to increase and the signal output from the meter to be unstable.
(5) If it is determined that the sensor is faulty, please contact the manufacturer of the electromagnetic flowmeter. The general site cannot be solved and needs to be repaired by the manufacturer.

Hot Products

High Accuracy Sewage Pipe Electromagnetic Flowmeter Product Description HKLD intelligent electromagn...
DN20 4-20mA Digital Large Pipe Size Insertion Electromagnetic Water Flowmeter With Battery Product ...
220VAC Power Supply Wastewater Electromagnetic Flow Meter Product Description HKLD intelligent ...
4-20ma Output Water Electromagnetic Flowmeter Milk Flow Meter Product Description HKLD intelligent ...
Flow Indicator And Lcd Display Electromagnetic Flowmeter Transmitter Product Description HKLD ...
Cheap price electromagnetic milk flowmeter with CE certificate Product Description HKLD intelligent ...