Customized Design Dry Cooler Remote Radiator 42000m3/H For Genset Engine Cooling

Country/Region china
City & Province dongguan guangdong
Categories Toilet Tissue
InquireNow

Product Details

Customized Design Dry Cooler Remote Radiator Easy To Install For Genset Engine Cooling

Quick Model Selection for Typical Units ( with AC fans) 
    ModelAir flow(m3/h)Heat capacity(kw)Water flow(l/s)Fan size(mm)Fan unit(pcs)Motor power(kw)Unit size(mm):L*W*H
LDDC-0101P-3R-AC630830024.871.2163010.741000*980*880
LDDC-0101P-4R-AC630880029.261.4463010.741000*980*900
LDDC-0101P-3R-AC7101100032.471.5771011.231150*1100*880
LDDC-0101P-4R-AC7101150038.021.8671011.231150*1100*900
LDDC-0102P-3R-AC6301660050.362.4363021.481950*980*880
LDDC-0102P-4R-AC6301760058.532.8663021.481950*980*900
LDDC-0102P-3R-AC7102200066.943.2371022.462250*1100*880
LDDC-0102P-4R-AC7102300076.243.7171022.462250*1100*900
LDDC-0103P-3R-AC6302490075.653.6663032.222900*980*880
LDDC-0103P-4R-AC6302640086.334.263032.222900*980*900
LDDC-0103P-3R-AC7103300099.864.8271033.693350*1100*880
LDDC-0103P-3R-AC71034500114.115.5471033.693350*1100*900
LDDC-0104P-3R-AC63033200102.354.9563042.963850*980*888
LDDC-0104P-4R-AC63035200116.535.6863042.963850*980*900
LDDC-0104P-3R-AC71044000134.916.5271044.924450*1100*880
LDDC-0104P-4R-AC71046000153.867.4871044.924450*1100*900
        

 

 

 

Note:
 
The above working conditions are based on 42℃/47℃ inlet/outlet temperature, the medium is pure water,
ainlet air temperature is 30℃.
If the actual working conditions are different from the reference working conditions, please contact the relevant
HVAC engineers for selection.
 
Product Description

 

A dry coolers is the same as air cooled condensing unit but utilizes some liquid solutions, such as water, ethylene glycol/water, to transfer hear being replace of refrigerant and compressor.

 

A dry cooler system are often see in Data centers where excess heat needs to be removed but low levels of humidity are not required.

 

A significant feature of dry cooler system is that no liquid evaporation takes place, which eliminates the need for make-up water.

 

As closed-circuit systems, dry coolers deliver several benefits compared to wet cooling towers, including lower initial costs and maintenance, improved system reliability and increased uptime.

 

Dry coolers can help to make a building working more efficiently. Though this system is not known for saving energy, it can be used as a condensing unit for a heat recovery chiller. When a heat recovery chiller supplements a chilled water system, there will be ask for a system to remove excess heat. This is the perfect application for a dry cooler, which serves as a condensing unit or cooling tower.

 

Why choose dry cooler replace of cooling tower?

 

No water consumption, eco-friendly - Dry Coolers do not require water. Instead, air is blown over a heat exchanger in order to remove the heat from the liquid in the system..
Easy maintainence - Dry Coolers are easier to maintain because the water is not exposed to air (closed loop) and they do not require water testing . Cooling Towers are susceptible to degradation through fouling (getting clogged up), scaling (water-deposit build-ups) corrosion (gradual breakdown due to the environment), and require testing for the prevention of Legionnaire’s disease.

 

Robust structure

 

Common dry cooler designs are flatbed units with either vertical or horizontal airflow direction or V-shaped units with one or two rows of axial fans with lateral air suction and discharge from the top.

 

 

Horizontal Airflow Direction

 

 

 

Vertical Airflow Direction

 

 

 

Application
 

Dry coolers are often used in applications where water is scarce or where the use of water is prohibited due to environmental regulations. They are also commonly used in industrial processes, such as power generation and chemical processing, where cooling is required to maintain optimal operating conditions.

 

Data center, office building, hospitals, industrial / process system, heat transfer / recuperation, power generation and induction cooling.

 
Longer Leader Advantages
 

no water consumption, easy maintenance, eco-friendly. 

 

 

 

 

Hot Products

Customized Design Dry Cooler Remote Radiator Easy To Install For Genset Engine Cooling Quick Model ...
Save Water Vertical Dry Coolers Suitable For Water-Scarce Areas Quick Model Selection for Typical ...
"V" Type With Dry Cooler With Copper Tube Low Nosie For Immersion Cooling Solution Quick Model ...
Outdoor Installation Hypothermia Air Handling Unit With Cooling Coil For Metallurgical Industry ...
Installed On The Roof With A Cart For Easy Movement Of The Cooling And Heating Air Handling Unit ...
Conveniently Mobile Rooftop Packaged Unit With Wheels Suitable For Precision Machinery Overview ...