Distance between PLC stations: 2Km
Cable type: GI-50/125.
The function of the MELSECNET interface module is to connect the
main PLC CPU to the MELSECNET data communication system.
Just use the switches on the component to set it,
It can be determined whether the PLC CPU serves as the main station
or the local station Mitsubishi A1SY81EP.
There are two types of modules to choose from: one is for hooking
up optical fiber networks, and the other is for hooking up coaxial
cable networks, A1SY81EP
For an ANSCPUs, only one interface component can be inserted, while
A2ASCPUs can be inserted with two components.
The promotion and application of PLC programming have achieved
rapid development in China,
It has been widely used in various mechanical equipment and
electrical control devices in production processes,
A large number of achievements in PLC transformation equipment have
emerged in various industries, including Mitsubishi A1SY81EP.
Understand the working principle of PLC and have the ability to
design, debug, and maintain PLC control systems,
It has become a basic requirement for electrical technicians and
engineering students in modern industry.
Instruction list programming language is a mnemonic programming
language similar to assembly language,
Like assembly language, it consists of opcodes and operands.
In the absence of a computer, it is suitable to use a PLC handheld
programmer to program the user program Mitsubishi A1SY81EP.
At the same time, the instruction table programming language
corresponds one-to-one with the ladder diagram programming language
diagram,
It can be converted to each other under PLC programming software.
Figure 3 is the instruction table corresponding to the PLC ladder
diagram in Figure 2.
The characteristic of instruction table programming languages is
the use of mnemonics to represent operational functions,
Easy to remember and master;
Using mnemonics on the keyboard of a handheld programmer is easy to
operate and can be programmed and designed in situations without a
computer;
There is a one-to-one correspondence with the ladder diagram for
the Mitsubishi output module. Its characteristics are basically
consistent with the ladder diagram language. Number of control
axes: 2-axis linkage, 2-axis independence.
Interpolation function: 2-axis linear interpolation, 2-axis
circular interpolation.
The A1SD75 series components demonstrate Mitsubishi's expertise in
manufacturing and designing CNC and frequency converters,
Comprehensive technical experience in servo systems and PLC.
These components have rich functions that are sufficient to meet
the high requirements of Mitsubishi output modules in positioning
control applications.
Multiple 3-axis linkage operations are available,
In low-cost motion control applications, this component can even
occupy only one slot but can operate and control up to 3 axes. Used
for writing EPROM 28 pin
Adapter SI/QSI/H-PCF/Wide H-PCF Optical Cable Dual Ring PC Network
(Control Station/Ordinary Station)/Remote I/O Network (Remote
Master Station) Mitsubishi Output Module
Block. With external power supply function.
The purpose of on-off control is to:,
Based on the current input combination of the switching value and
the historical input order,
Enable the PLC to generate corresponding switch output,
To enable the system to work in a certain order.
So, sometimes also known as sequential control.
And sequential control can be divided into manual, semi-automatic,
or automatic.
The control principles adopted include decentralized, centralized,
and hybrid control.
The time required for instruction execution is closely related to
the length of the user program, the type of instruction, and the
CPU execution speed,
Generally speaking, during a scanning process, the fault diagnosis
time is,
The communication time, input sampling, and output refresh take up
less time,
The execution time accounts for the majority.
The response time of PLCC refers to the interval between the time
when the external output signal of the PLC changes and the time
when it controls the change of the external output signal
Septum,
It is called lag time, which is determined by the input circuit
time constant,
The time constant of the output circuit, the arrangement of user
statements, and the use of instructions,
The PLC's cyclic scanning method and the PLC's refresh method for
I/O constitute Mitsubishi A1SY81EPA1SY81EP.
This phenomenon is called the I/O delay time effect.
Our advantage Products:
【Yaskawa】Servo Drive / Servo Motor
【Mitsubishi】Servo Drive / Servo Motor
【Honeywell】Module DCS / PLC
【Emerson】DeltaV Module / Servo Motor
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive
(Modicon,SMC,SICK,NORGREN,Siemens etc.)
Linture Technology Co,. Ltd
Contact person: Vivian
E-mail: linture0319@163.com
Cellphone: +0086-18026552038
Wechat:18026552038
WhatsApp:+86 18026552038
Tag:electric servo drive,
ac servo drive,
ac servo pack