Plastic Industrial Injection Molding Machine High Efficient 3 Minutes Quick Mold Change System

 

 

 

Basic Composition and Operation Process

Magnetic template sucker with a piece of steel plate is processing in a special milling machine, the structure is more compact, rigid and solid. Inside with imported epoxy resin sealed magnetic coil and magnet which is high-temperature resistance and dynamic resistance. The sealing part height is slightly lower than the magnetic pole surface which is to avoid the air gap occurred by mold and magnetic template when temperature increased too high. The magnetic template is drilled with a fixing hole for installation and a die ejection hole on one side of the dynamic template, also with positioning ring which is used to position the mold quickly.

 

Quick Mold Change System Components

 

Standard Configuration
Magnetic Plate1 SetMoveabla & Fixed side, Upper & Lower side
Main Control Cabinet1 Set4, 8, 12 Channels.
Remote Controller1 SetMechanical type and intelligent LCD touch type
Connecion Cables1 SetControl cable, power cable, Signal cable, etc.
Accessories1 SetMounting screws, mounting rings, positioning rings
Optional ConfigurationOptional Functions
Fall Prevention ChainTemperature DetectionMisalignment Detection
Die LifterProximity DetectionForce Strength Detection
Die ArmMagnetic SaturationMagnetic Flux Detection

 

 

 

Magnetic Plate Technical Parameter

 

ItemStandard Magnetic PlateCelluar Magnetic PlateFull-Steel Magnetic Plate
Pole Size50*50mm70*70mm80*80mm70mm Hexagon50*50mm70mm Hexagon
Magnetic Strength Unit Area16kgf/cm²16kgf/cm²16kgf/cm²15kgf/cm²15kgf/cm²15kgf/cm²
Magnetic Strength Per Poles350kgf735kgf980kgf640kgf735kgf640kfg
Magnetic Plate Thickness35, 45mm50mm52mm37mm37, 47mm48mm
Magnetic Flux Penetration Depth15mm18mm20mm18mm18mm18mm
Ejector HoleStandardStandardStandardStandardStandardStandard
Control SystemMain Contorl CabinetC4C4/ C8C8C4/ C8C4/ C8C4/ C8
Remote ControllerQRC-A
QRC-AC
QRC-A
QRC-AC
QRC-A
QRC-AC
QRC-A
QRC-AC
QRC-A
QRC-AC
QRC-A
QRC-AC
Max. Working Temperature120℃,150℃
Standard VoltageAC 220V~480V, 50/60HZ
Proximity Sensor≤5000KN1pc1pc-1pc1pc1pc
>5000KN-2pc2pc2pc2pc2pc
Sensing Distance0.2mm
Temperature SensorStandard, Detection temperature from 60 to 200 degrees
Dislocation SensorStandard, Detection accuracy 0.1mm
Magnetic Saturation SensorStandard, Detect whether the electric current is saturated
Magnetic Flux SensorOptional, Detect changes in magnetic flux
Force MeasurementOptional, Detect the strength of the magnetic force
Surface Seal Material for Both Side of Magnetic PlateSurface Material of Front SideResinResinResinMetalMetalMetal
Surface Material of Back SideMetalMetalMetalMetalMetalMetal

 

 

 

 

Advantages of Magnetic Clamping System

 


1. Easy Installation
It does not require any changes to the molds,no need to change the appearance and structures, no need punch, just fix the magnetic plate by bolts in the rear panel threaded hole or T-slot of the injection molding machine.

 

2. High Safety
The Magnetic quick mold change is controlled by Electro-permanent magnet system which is an electrical pulse activates the system in a second (Magnetization): the mold is held by the natural force of the permanent magnets. The clamping force remains constant even in the absence of a power supply, it is still keep strong and continuously magnetic force when power off and does not disappear or loss by time and temperature factors.

 

3. High Efficiency
Use Magnetic quick mold clamping system can greatly improve the mold change efficiency, drastically reduces mold changeover times (up to 90%) compared to a conventional procedure. QMCS guarantees a uniform mold clamping, that is held using the whole contact surface. Clamping the mold with uniformity allows obtaining good quality parts even with the first molds. The two mold halves are perfectly aligned: friction is minimized, preserving wear of molds and the machine. Generally the mold change and mold clamping only need 3 minutes, large mold change only needs 10 minutes.

 

4. Save Space
The thickness of Magnetic plate is about 37-50mm, space is small. The magnetic quick mold clamping system does not use platens and other pneumatic and hydraulic components,save more space and make all the peripherals of the mold in the injection molding machine are easy for maintenance and operation.

 

5. Easy Operation

Magnetic quick mold clamping system clamps molds of any shape and size with strength. A single operator easily and safely performs the operation, without working inside the machine.

 

6) Economical and Practical
Use Magnetic quick change mold system means eliminating the cost of maintenance and management of brackets, consumables, fasteners.Electricity is only used to fix and release clamping, once the mold is safely held to the correct position, will no longer need to use the electricity. Magnetic chuck application temperature can maximum up to 150°C, machine weight up from 60 tons to 5000 tons.

 

 

Pre-Sale Info Sheet

Customer Information
Company Name Company Address 
Contact Person E-mail 
Telephone Fax 
Injection Molding Machine Information
IMM Brand&Model 
Opening ForcekN

 

Clamping ForcekN
Nozzle ForcekN
Ejector ForcekN
Mould Capacitymm
Max temperature of Mould
Enclose Back- plate Drawing 
Mold Information
Mold ParameterLength(mm)Width (mm)Height (mm)
Maximum size of the moldmmmmmm
Minimum size of the moldmmmmmm
 
The max weight of moldkgThe min weight of moldkg
Diameter of Mold Centering ringmmMold Back-plate Material 
Mold with Insulation boardYES
No
Mold with automatic thread demoulding structureYES NO

 

FAQ

1. How can i place an order?
Please provide the details of your requirements as clear as possible. So we can send you the offer at the first time.
For designing or further discussion, it is better to contact us with Skype / email / phone, in case of any delays.


2. What's the Difference Between Electromagnet and Electro-permanent magnet?
Both industrial magnets are electrically switched on/off. The main difference lies in 2 points.
First, electromagnet works on consistent electric power; if cutting off the power supply suddenly, it losses magnetic force. What distinguishes electro-permanent magnet from electromagnet is that the former does not use electricity during working. If cutting off the power, it can remain holding/lifting/gripping/clamping of the load.
Second, due to continuous power input, electromagnet has heat generation which might affect its workholding effectiveness during machining. Whereas that is no problem to EPM.

 

3. How about the warranty ?
We have 1 year warranty and lifelong maintenance.


4. What is your terms of delivery?
We accept EXW, FOB, CFR, CIF, DDU, DDP, etc. You can choose the one which is the most convenient or cost effective for you.

 

Hot Products

Industrial Automation Magnetic Quick Mold Clamping System For Injection Molding Machine Die Change ...
Time Saving Industrial Injection Mould Magnetic Mold Clamping System Magnetic template has an ...
Magnetic Clamping System Quick Mold Clamp For Vertical Plastic Injection Machine Extend mold life, ...
Large Tonnage Injection Molding Machine Magnetic Clamp Quick Mold Change System To avoid the ...
Plastic Industrial Injection Molding Machine High Efficient 3 Minutes Quick Mold Change System Basic ...
Efficiency Improve Magnetic Mold Clamping System Used For Injection Molding Machine Why we need to ...