CCT and Power Tuanable LED Troffer Light Specification
Model No | DLC | Input Voltage | Wattage | Lens | CRI/CCT | Rated Lumen @ 30K | Rated Efficancy @ 30K | Viewing Angle | Rated Lifetime | Replacing |
N-TR-24-40-XX-WC1
| P |
120-347VAC/ 120 - 277VAC 0- 10V Isolated Dimmable | 40W | Frosted |
Ra>80, 30K / 35K 40K / 50K
| 5000LM | 125 LM/W | 120° |
L70> 50000hrs |
60W - 200W Incandescent |
N-TR-24-34-XX-WC1
| P | 34W | 4250LM | |||||||
N-TR-24-26-XX-WC1
| P | 26W | 3250LM | |||||||
N-TR-24-20-XX-WC1 | P | 100-277VAC or 100-347VAC | 20W | Frosted |
Ra>80, 30K / 35K 40K / 50K
| 2500LM | 125 LM/W | 120° | L70> 50000hrs | 60W - 200W Incandescent |
N-TR-24-50-XX-WC1
| P | 120-347VAC/ 120 - 277VAC 0- 10V Isolated Dimmable | 50W | Frosted | Ra>80, 30K / 35K 40K / 50K | 6250LM | 125 LM/W | 120° | L70> 50000hrs | 60W - 200W Incandescent |
N-TR-24-45-XX-WC1
| P | 45W | 5625LM | |||||||
N-TR-24-40-XX-WC1
| P | 40W | 5000LM | |||||||
N-TR-24-30-XX-WC1
| P | 30W | 3750LM | |||||||
N-TR-14-27-XX-WC1
| P | 120-347VAC/ 120 - 277VAC 0- 10V Isolated Dimmable | 27W | Frosted |
Ra>80, 30K / 35K 40K / 50K | 3375LM | 125 LM/W | 120° |
L70> 50000hrs | 60W - 200W Incandescent |
N-TR-14-24-XX-WC1
| P | 24W | 3000LM | |||||||
N-TR-14-20-XX-WC1
| P | 20W | 2500LM | |||||||
N-TR-14-16-XX-WC1
| P | 16W | 2000LM | |||||||
N-TR-14-40-XX-WC1 | P | 120-347VAC/ 120 - 277VAC 0- 10V Isolated Dimmable | 40W | Frosted | Ra>80, 30K / 35K 40K / 50K | 5000LM | 125 LM/W
| 120° | L70> 50000hrs | 60W - 200W Incandescent |
N-TR-14-36-XX-WC1
| P | 36W | 4500LM | |||||||
N-TR-14-30-XX-WC1
| P | 30W | 3750LM | |||||||
N-TR-14-25-XX-WC1
| P | 25W | 3125LM | |||||||
N-TR-22-27-XX-WC1
| P | 120-347VAC/ 120 - 277VAC 0- 10V Isolated Dimmable | 27W | Frosted |
Ra>80, 30K / 35K 40K / 50K | 3375LM | 125 LM/W | 120° | L70> 50000hrs | 60W - 200W Incandescent |
N-TR-22-24-XX-WC1
| P | 24W | 3000LM | |||||||
N-TR-22-20-XX-WC1
| P | 20W | 2500LM | |||||||
N-TR-22-16-XX-WC1
| P | 16W | 2000LM | |||||||
N-TR-22-40-XX-WC1
| P | 120-347VAC/ 120 - 277VAC 0- 10V Isolated Dimmable | 40W | Frosted | Ra>80, 30K / 35K 40K / 50K | 5000LM | 125 LM/W | 120° | L70> 50000hrs | 60W - 200W Incandescent |
N-TR-22-36-XX-WC1
| P | 36W | 4500LM | |||||||
N-TR-22-30-XX-WC1
| P | 30W | 3750LM | |||||||
N-TR-22-25-XX-WC1
| P | 25W | 3125LM |
Accessories
BI-LEVEL 12V PIR SENSOR/PIR SENSOR WITH DAYLIGHT HARVESTING
Specification
Sensitivity: 100%/25%, 50%, 75%, 100%Default Setting/Setting
MICROWAVE MOTION SENSOR
Sensitivity: 25%, 50%, 75%, 100%Default Setting/Setting
Specification
*Sink Current: Max.100mA
4W OR 8W UL LISTED EMERGENCY BACKUP
Advantages
HOW TO CHANGE THE WATTAGE & CCT IN THIS FIXTURE
Power Adjustable Slide Switch Position | ||||
Size/Positon | 0 | 1 | 2 | 3 |
1X4 | 27W | 24W | 20W | 16W |
40W | 36W | 30W | 25W | |
2X2 | 27W | 24W | 20W | 16W |
40W | 36W | 30W | 25W | |
2X4 | 40W | 34W | 26W | 20W |
50W | 45W | 40W | 30W |
CCT Tunable Slide Switch Position | |
Position/Group | CCT |
Low | 3000K(Optional) |
Middle 1 | 3500K |
Middle 2 | 4000K |
High | 5000K |
CCT and Power Tuanable LED Troffer Light Installation
Suitable for surface mounted, suspended mounted.
WARNING
INSTRUCTION FOR SURFACE MOUNTING
TR - SL/F
·1.Disconnect or turn off power before installation,see step ①.
·2.Put the new volumetric troffer fixture onto the T grid,see step②
·3.Make the electrical connection to the fixture in accordance with
local electrical code.Make all necessary
wiringconnections,observing proper voltage and polarity.See step@ .
Make sure the power feeds are put into the fixturejunction box.
·4 Once finished with the electrical connection, bend the earthquak
clips to attach to the T grid.See step④
·5.Turn on power, the fixture will illuminate. See step .
TR - SLK
·1.Disconnect of turn off power before installation. See Step 1
·2.Remove the old lens, fluorescent tubes and ballast (if necessary)
from fixtures. See Step ②
·3.Insert these brackets between the T grid and old fixture housing.
Seet Step ③
·4. Fasten screw and hang the LED troffer retrofit from the
bracket.See Step ④ Screw the safety cables to theold fixture
housing. See Step ⑤
·5.Make the electrical connection to the fixture in acccordance with
local electrical code.Make all necessaryconnections, observing
proper voltage and polarity. See Step⑥
·6.Once finished with the electrical connection, swing LED troffer
retrofit so it sits flush, then using the hooks onthe opposite end
of the brackets secure retrofit into place.See Step⑦
·7.Turn on power, the fixture will illuminate. See Step ⑨
Lighting Service
NOONLIGHT Core Team have more than 15 years of experience in lighting industry. We are able to offer our valuable clients:
· OEM/ODM Serivce · Photometric/IES file
· PCB Design/Driver Design · Heat Management/Optical Design
· Industry Design · Market Support
· 3D Printing · Multiple Listing/Private Label.
CCT and Power Tuanable LED Troffer Light Applications
Schools, offices, conference room, hospitality etc.