Fractional Vacuum Rf Microneedle Gold Radio Frequency Micro Needle Rf Skin Rejuvenation Vacuum Rf Lifting Machine

Country/Region china
City & Province beijing beijing
InquireNow

Product Details

 

Radio Frequency , we call it RF.RF is a high frequency AC change electromagnetic wave short. RF is such a high frequency current.

The principle of radio beauty instrument is to let the dermis layer heat up, so that collagen growth and remove wrinkles.

Our skin has the ability to grow and repair itself. After the skin is injured, the ability to grow and repair is several thousand times faster than usual, and the collagen will increase significantly. When it reaches 45-60 degrees in a certain time, it will stimulate the cells to secrete new collagen. So as to achieve the effect of skin rejuvenation and skin lightening. Radio beauty equipment is the best effect of the original wrinkle instrument. Compare with Laser, radiofrequency treatment is not affected by skin color.

 

What is Fractional?

 

Normal RF is sending all energy to skin, but Fractional RF sending energy out as each point, it not damage skin , and easy to be absorbed.

The principle of radiofrequency treatment: Radiofrequency energy through the needle to reach the dermis layer, heat up skin and stimulate the proliferation of collagen, to promote the re-arrangement of elastic fibers, to achieve skin tightening and wrinkle removal effect. The energy is more even.

Micro needle rf machine add vacuum on the original basis of radio frequency. The vacuum absorbs the skin, and then the needling release energy,it can avoid the uneven energy of the needle intrusion into the skin due to skin elasticity. The treatment effect is better than ordinary radio frequency.

 

 

Treatment process

Micro Needle RF handle:

(1) Facial cleaning

(2) Apply anesthetic cream as needed (apply anesthetic cream and cover with plastic wrap for 30-60 minutes)

(3) Disinfect the treatment area.

(4) Choose the parameters according to the recommended parameters, test at the edge of the treatment area , the customer can tolerate the pain mean good parameter

(5) Requirements for the treatment area:

--Contraindicated areas:- close to bones, eyes ,Upper eyelid, Adam’s apple, clavicle, knee, knee internal test, tail vertebra, belly button, both sides of pelvis, hands, feet...

Restricted area of treatment depth: nerve-intensive area, close to the bone (if tightening the skin, the fat thickness need more than 20mm from the bone.unnecessary burns.

Application:

 

Suitable for All Body Treatment

MICRO NEEDLE RF Applicator

MICRO NEEDLE RF (RF) applicator for procedures requiring ablation and resurfacing of the skin.

Add vacuum suction combined probe for better skin contact, especially around eyes and neck areas.

1. Stepping Motor Type

Stepping Motor Type, different to existing solenoid type, the needle inserts to the skin smoothly with no shock, and causes no bleeding and no pain after the procedure

 

2. Needle Depth Control

5-4.0mm [0.2mm Step]

Operate epidermis and dermis layer by controlling the needle depth in unit of 0.2mm.

 

3. Gold Plating

Needle is durable and also have high biocompatibility by applying Gold Plating. Patient with Metal allergy could also use it with not conceming Contact Dermatitis.

 

4. Safety Needle System

Sterilized disposable needle tip

operator can easily notice the applying RF energy from LED light.

 

5. Needle Thickness: 0.2mm

The needle structure is easy to penetrate the skin with mininum resistance.

 

 

Effect

 

 

Specification:

Specifications 
System TypeMono & Bipolar RF
 Bipolar RF
Frequency2MHz
Total RF Treatment LevelUp to Level 10
Dual Operation ModeFractional RF Micro-needle
 Fractional RF Sub-lative
Max Energy50W
Disposable TipMicro-electrode needle
 Micro- electrode tip
Depth of Needle0.5 - 3 mm (Adjustable)
Cooling head-10℃
Display10.4 inch LCD
SwitchFoot Switch
Dimension(mm)280mm(W) x 505mm(L) x 1100mm(H)
Weight20kg
Electrical RequirementsAC/100-240 V, 50-60 Hz

Hot Products

Description P-MIX TRIPLE WAVELENGTH DIODE LASER HAIR REMOVAL MACHINE Professional Hair Removal ...
ICOOL Air Cryo Skin Cooling System Introduction: The ICOOL Cold Air skin cooling system is the ...
Description Laser Cryo Air Chiller Skin Cooling System Introduction: The Laser Cryo Air Chiller Skin ...
Description Working Therapy The 1500W high-power compressor provided by Danfoss ensures that the ...
Description Working Therapy The 1500W high-power compressor provided by Danfoss ensures that the ...
Radio Frequency , we call it RF.RF is a high frequency AC change electromagnetic wave short. RF is ...