Home Companies Delta Technology(Chongqing) Co., Ltd.

CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment

Delta Technology(Chongqing) Co., Ltd.
Active Member

Contact Us

[China] country

Address: No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010

Contact name:Tina Chen

Inquir Now

Delta Technology(Chongqing) Co., Ltd.

CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment

Country/Region china
City & Province chongqing chongqing
InquireNow

Product Details

CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment

Introduction:

CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment is used to measure all kinds of current transformer and voltage transformer.

CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test.

CPT-III Current Transformer and Voltage Potential Transformer Testing Equipmentcan automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.

Application:

Tests for current transformer:

  1. Excitation curve and parameters test
  2. Turns ratio test
  3. Ratio and phase error test
  4. Polarity mark check
  5. Winding resistance measurement
  6. Secondary loop burden measurement
  7. Error line curve test for protection CT
  8. Transient CT parameters test
  9. CT nameplate guess
  10. Saturation hysteresis loop curve measurement

 

 

Tests for voltage transformer:

  1. Turns ratio test
  2. Ratio error and phase angle error test
  3. Polarity test
  4. Secondary burden test
  5. Winding resistance test

 

Applications for CTPT analyzer:

  • CT nameplate check
  • CT parameters check in work burden
  • CT transient parameters analysis
  • CT ratio and phase error calibration
  • PT routine test

 

Parameters:

1Test standardsIEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2Power supplyAC220V±10%,50Hz/60Hz±10%
3Power output0.1~180V (AC)
4Current output0.001~5A(RMS)
5Power output300VA
6Max. knee voltage measurement45kv
7Current measurement range0~10A (automatically change range in 0.1/0.4/2/10A)
8Current measurement error<±0.1%+0.01%FS
9Voltage measurement range0~200 V (automatically change range in 1V/10V/70V/200V)
10Voltage measurement error< ±0.1%+0.01%FS
11Turns ratio measurement range

1~35000;

1~2000 error<0.05%;

2000~5000 error>0.1%;

5000~35000 error<0.2%

12Phase measurementerror:±2min,resolution:0.01min
13Coil resistance measurement

Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)

Error< 0.2%RDG+0.02%FS

Maximum resolution: 0.1mΩ

14Temperature measurement-50~100 Celsius degree, error<3 Celsius degree
15CT Secondary burden

Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)

Error <0.2%RDG+0.02%FS

Maximum resolution 0.001ohm

16PT Secondary burden

Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)

Error <0.2%RDG+0.02%FS

Maximum resolution: 0.1ohm

17PT ratio measurement

Range: 1~35000,

1~5000 error<0.2%

5000~35000 error<0.5%

18Saved data groups>1000groups
19Work conditionTemperature:-10℃-50℃, moist:≤90%
20Size485mm×356mm×183mm
21Weight<15Kg
 

 

 

CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment Real Picture:

 

Hot Products

PRT-PC6 Fully Automatic Multi-Functional Six Phase Relay Test Set Introduction: Embedded host ...
Zk-III Low Price Durable Transformer Short Circuit Impedance Tester Introduction: Zk-III Circuit ...
ZK-III China Manufacturer Durable Transformer Short Circuit Impedance Tester Introduction: ZK-III ...
CPT-III 220V to 500kv Power Current Transformer Testing Equipment Introduction: CPT-III Power ...
CPT-III Current Transformer and Voltage Potential Transformer Testing Equipment Introduction: CPT...
CPT-III 220V to 500kv Power Current Transformer Testing Equipment Introduction: CPT-III Current ...