Home Companies Labnovation Technologies, Inc.

HbA1c analyzer Fully Automated HPLC HbA1c Analyzer Diabetes Control Machine

Labnovation Technologies, Inc.
Active Member

Contact Us

[China] country

Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China

Contact name:Aimee li

Inquir Now

Labnovation Technologies, Inc.

HbA1c analyzer Fully Automated HPLC HbA1c Analyzer Diabetes Control Machine

Country/Region china
City & Province shenzhen
Categories Chargers
InquireNow

Product Details

HbA1c Analyzer Fully Automated HPLC HbA1c Analyzer Diabetes Control Machine

 

User Friendly-To Avoid Operator Error
10" Touch Screen with Vivid Color
Easy to Understand and Pellucid Software
Only one type of sample rack required for all different tubes
Reagent Alarm- Monitor Reagent Residue for Timely Reminder
Flexible -To Satisfy Diverse Laboratory's Needs
Different sample tubes can be loaded in any order in any rack
20 Sample Loader Available for Laboratory Automation
Highly customizable remarks to meet your needs
Complex System Functions -For Easy Integration
USB, USB and RS232 ports offer flexible connectivity for LIS/HIS systems
Compact Size -To Minimize Space Requirements
Small Footprint Reduces Bench Space Needed

 

 

Specification

MethodHigh-Performance Liquid Chromatography (HPLC)Sample loading capacity20 Tubes
Test ModesFast Mode, Variant ModePhotometer420nm
Sample TypeWhole blood, Pre-diluted bloodColumn Capacity3000T
Test Speed90 Seconds/TestFilter Capacity600T
Test Range3% - 18%Storage5000 Sample Results
CV Precision≤2%Sample Volume5μL

 

 

HPLC Methodology

 

High-Performance Liquid Chromatography (HPLC), to separate HbA1c directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbAlc testing result, excluding interference of variant and unstable hemoglobin like HbF. Standard Analysis Mode will report HbA1a, HbA1b, HbF, HbA1c, P3, HbA0 peak areas and ratio. And the result also includes IFCC, NGSP and eAG value for diverse client needs.

 

 

Reagents and Consumables

The analyzer is recommended to be used in conjunction with the Glycosylated Hemoglobin Test Reagent Kit (high performance liquid chromatography (HPLC method)) produced by our company, which includes the following components:
 
600T: Eluent A/Eluent B/
Eluent C(Variant Mode)
Adjusts the pH of the solution for the elution of glycosylated hemoglobin and non glycated hemoglobin.
600T: Hemolysis ReagentUsed to dissolve red blood cells and release hemoglobin.
3000T: Chromatography ColumnUsed for separation and elution of glycosylated hemoglobin and non glycated.
600T: Hemoglobin FilterUsed to initially filter the sample after hemolysis.
12Pcs: Paper RollsPrints a report of the test results.
 


 

Certificate

Hot Products

HbA1c Analyzer Automated HbA1c Analyzer LD-500 Hematology Daignostic HbA1c Analyzer Intended Use LD...
HbA1c Analyzer Automated HbA1c Analyzer LD-500 Hematology Daignostic HbA1c Analyzer Intended Use LD...
HbA1c Test Analyzer LD-500 Automatic HbA1c Analyzer Intended Use LD-500 is an automatic instrument ...
Fully Automated HbA1c Analyzer For Hba1c Test With 600T Reagent Kit Internation Gold Standard: HbA1c ...
HbA1c Analyzer Fully Automated HPLC HbA1c Analyzer Diabetes Control Machine User Friendly-To Avoid ...
Fully Automated HbA1c Analyzer Lab Equipment Medical Blood Testing Use HbA1c results in 90 seconds . ...