High Performance Liquid Chromatography HbA1c Test Analyzer IFCC NGSP

Country/Region china
City & Province shenzhen
Categories Electric Wrenches
InquireNow

Product Details

HbA1c Analyzer LD-560 Fully Automaic HbA1c Testing Analyzer HPLC System For Hemoglobin Testing

Intended Use

  • The Fully Automated HbA1c Analyzer is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
  • This analyzer is a fully automated instrument used to analyze glycosylated hemoglobin. It has the characteristics of small sample amount and simple operation. It is suitable for the detection of glycosylated hemoglobin in medical institutions.
  • The analyzer consists of an auto sample injection module, a liquid chromatography separation module, a colorimetric detection and control module, a barcode scanning module, and a display printing module.

Specifications

Name

Fully Automated HbA1c Analyzer

ModelLD-560
MethodHPLC(High Performance Liquid Chromatography)
ParametersHbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional)
Test Speed90 seconds per test
Wavelength420nm
Sample TypeWhole Blood, Pre-diluted blood
Autoloader Capacity20 tubes
PrecisionCV<2%
Column Capacity3000 tests
Working ConditionTemperature: 15-30℃
Net weight28kg
Storage environment: Temperature-20℃~55℃
Humidity10%~93%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Principle

Using high performance liquid chromatography (HPLC), the stationary phase used is a weakly acidic cation exchanger. Glycosylation of hemoglobin will result in the loss of cations on the surface of hemoglobin without being charged, and non-glycosylated hemoglobin has a positive charge.

Feature

  • Information Input
  • Sample Dispense
  • Automatic Detection
  • Result Output
  • Easy Operation
  • Fast Testing Speed

Advantage

  • HPLC Method 
  • Full Automation
  • Smart System
  • Best Quality And Performance
  • Most Cost-effective
 

 

Performance Parameters

 

  • Reporting unit: Glycosylated hemoglobin (HbA1c) is reported in NGSP (%) and IFCC units (mmol/mol).

  • Accuracy: The accuracy is tested with reference materials as samples, and the relative deviation of the test results should be within ±5%.

  • Stability Within 8 hours after the analyzer is turned on and stabilized, the same normal sample is tested, and the relative deviation of the test results is not more than ±3.0%.

  • Carrying pollution: The carrying pollution rate of the analyzer should not be greater than 2.0%.

 

Certificated

 

 

Hot Products

Smart Auto Hematology Analyzer Fully Automatic HbA1c Test Analyzer Intended Use Low Maintenance, ...
Hematology Analyzer Fully AutomatED HbA1c Analyzer LD-560 HbA1c Analyzer Intended Use The Fully ...
HbA1c Test Analyzer LD-560 HbA1c Testing With HPLC System Latest Medical Hematology Equipment ...
HbA1c Analyzer LD-560 HbA1c Test Analyzer HPLC System For HbA1c Testing Hematology Test Analyzer ...
HbA1c Analyzer LD-560 Fully Automaic HbA1c Testing Analyzer HPLC System For Hemoglobin Testing ...
HbA1c Analyzer Fully Automatic LD-560 Hemoglobin Detection Analyzer HPLC Method Support Intended Use ...