10 Min To 15 Min Rapid Saliva RTK Test Kit Easy To Carry

Country/Region china
City & Province shenzhen
InquireNow

Product Details

Rapid Antigen Test Kit CoV-19 Antigen Saliva Rapid Test Self Test 1 Test High Accuracy Easy Use Test Kit


Intend Use

SARS-CoV-2 antigen saliva rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in human saliva sample from novel coronavirus suspected person with symptoms within 9 days from onset. The test result can be used for early detection and triage of people suspected of being infected.Further nucleic acid detection should be carried out for suspected population whose antigen test result is positive or negative.

 

Product Details

ItemValue
NameSARS-CoV-2 Antigen Saliva Rapid Test Kit (Self Test)
Model NumberLX-401602
Type 1 Test
Warranty18 Months
Power SourceInstruction Manual
Quality CertificationCE
Safty StandardISO13485
Sample TypeSaliva
Sample volume3 Full drops
Test SpeedWithin 10-15 minutes
Total AccuracyOver 95%
Sensitivity94.29%
Specificity99.00%

 

Product  Feature

  • Immunochromatography Assay
  • 1 Test / Kit, Easy to carry
  • Self Testing, not need extra instrument
  • Saliva Sample, more comfortable than others


Advantage

  • Fast test speed, get the test result within 10-15 mins
  • High quality, after test the background is very clean
  • One step operation without other requirement
  • Safety and reliable, high accuracy, specificity and sensitivity

 
Main Components

  • Test Cassette
  • Saliva Collectors With Collection Tube
  • Sample Extraction Buffer
  • Instruction Manual

 
Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 

 
Virus Sources

Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
B.1.1.33.etcC.1.1.etc. 

 
Precaution

  • For IN VITRO diagnostic use only.
  • Waste should be treated in accordance with infectious substances and should be discarded properly.
  • The extraction reagent contains preservative agent which may be toxic if ingested. When disposed of through a sink, flush with a large volume of water.
  • Do not use samples that have been placed for longer than one hour or contaminated.
  • If the saliva is not well mixed in the sample extraction tube, false negative results may occur.

Hot Products

Rapid Antigen Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Self Testing With High Accuracy Antigen ...
Rapid Test Kit Antigen Saliva Testing CoV-2 Antigen Saliva Rapid Test Kit Self Test For Home Use ...
Rapid Test Kit Antigen Saliva Rapid Test CoV-2 Antigen Saliva Rapid Testing Single Pack Self Test ...
Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Kit 1 Test For Self Testing Protable Rapid ...
Rapid Antigen Test Kit CoV-19 Antigen Saliva Rapid Test Self Test 1 Test High Accuracy Easy Use Test ...
Rapid Test Kit COVID-19 Antigen Saliva Rapid Test Kit 1 Test Self Testing Simple Operation High ...