Home Companies Labnovation Technologies, Inc.

CE ISO13485 COVID-19 RTK Saliva Self Test Kit For IN VITRO Diagnostic

Labnovation Technologies, Inc.
Active Member

Contact Us

[China] country

Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China

Contact name:Aimee li

Inquir Now

Labnovation Technologies, Inc.

CE ISO13485 COVID-19 RTK Saliva Self Test Kit For IN VITRO Diagnostic

Country/Region china
City & Province shenzhen
Categories Scanners
InquireNow

Product Details

Rapid Test Kit COVID-19 Antigen Saliva Rapid Test Kit Self Test 1 Test Single Pack Protable Test Kit


Intend Use
This rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in human saliva sample from novel coronavirus suspected person with symptoms within 9 days from onset. The test result can be used for early detection and triage of people suspected of being infected. 

 

Product Details

ItemValue
NameSARS-CoV-2 Antigen Saliva Rapid Test Kit (Self Test)
Model NumberLX-401602
Type 1 Test
Warranty18 Months
Power SourceInstruction Manual
Quality CertificationCE
Safty StandardISO13485
Sample TypeSaliva
Sample volume3 Full drops
Test SpeedWithin 15 minutes
Total AccuracyOver 95%

 

Product  Feature

  • Protable and convenient
  • High Accuracy, Sensitivity and Specificity
  • Excellent Performance, Strong test line and control line
  • Easy for use, sample collected is very easy



 
Main Components

  • 1 Test Cassette
  • 1 Saliva Collectors With Collection Tube
  • 1 Sample Extraction Buffer
  • 1 Package Insert

 
Sample Collection

  • 30 minutes before sampling, please do not eat, smoke, drinking alcohol or drinks.
  • Place the tip of tongue against the upper or lower tooth root to enrich saliva, and then swallow saliva to the throat without ingesting saliva to esophagus, followed by returning saliva to the mouth. Repeat the process for 5 times.

Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 

 
Virus Sources

Global high frequency mutationAlpha / B.1.1.7(U.K.)Beta I B.1.351(South Africa)
Gemma I P.1(Brazil)Kappa I B.1.617.1(India)Delta I B.1.617.2(India)
C.37,ectAlpha I B.1.17(U.K.)B.1.36.16.etc
A.2.5,etcA.23.1Alpha I B.1.17(U.K.)
B.1.1.33.etcC.1.1.etc.etc.

Storage And Expiry

Store as packaged in the sealed pouch at 2-30℃, avoid heat and sunshine, dry place, valid for 24 months. Do not freeze. Do not open the inner packaging until ready, it must be used within one hour if opened (Humidity≤60%, Temp: 20℃-30℃). Please use immediately when the humidity>60%.
Precaution

  • For IN VITRO diagnostic use only.
  • Waste should be treated in accordance with infectious substances and should be discarded properly.
  • The extraction reagent contains preservative agent which may be toxic if ingested. When disposed of through a sink, flush with a large volume of water.
  • Do not use samples that have been placed for longer than one hour or contaminated.
  • If the saliva is not well mixed in the sample extraction tube, false negative results may occur.

FAQ

  • Production quantity?

It depends on the specification of the products. For big orders, we can produce 100k-250k per day.

  • Have after-sale service?

Yes we support technical services. And if the goods are missing due to our fault, we promise to compensate.

  • Register your products in our country?

Yes. We can offer full files for you to register.

  • Lead time?

Stock 3-7 days in general. Or please contact us by email for specific lead time base on your order quantities.

 

  • Support ODM or OEM?

Yes we support both. If needed,welcome to discuss details with us.

Hot Products

Rapid Test Kit CoV-19 Antigen Saliva Rapid Test Kit Saliva Sample 1 Test Sigle Pack Protable Antige ...
Rapid Test Kit Antigen Saliva Rapid Test CoV-19 Antigen Saliva Rapid Test Single Pack For Self Test ...
Rapid Test Kit SARS-CoV-2 Antigen Rapid Test Kit Single Pack Self Testing High Specificity Antigen ...
Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Kit 1 Test Self Use Esay To Operate Rapid Test ...
Rapid Test Kit COVID-19 Antigen Saliva Rapid Test Kit Self Test 1 Test Single Pack Protable Test Kit ...
Rapid Test Kit SARS-CoV-2 Antigen Saliva Rapid Test Kit 1 Test For Self Testing Protable Rapid ...