Beijing Samyon Instruments Co., Ltd. |
|
SLPT Automatic static load pile tester(6channels)
Application:
It is used for testing the pile loading capacity by static method. The
system will automatically collect the data through the control box
with 4pcs displacement sensor. It can be used to test the
compressive loading, and it can also do the lateral loading with
special designed jacks. The displacement sensor can be installed as
two methods, to beam or to pile. So it will be suitable for any
complex installation position.
Standard:
ASTM D1143 Standard Test Method for Deep Foundations Under Static
Axial Compressive Load
ASTM D3689 Standard Test Method for Individual Piles Under Static
Axial Tensile Load
ASTM D3966 Standard Test Method for Deep Foundations Under Lateral
Load
Parameters:
Item | Name | Details |
1 | Main host | Cable or Wireless connection |
2 | Data control box | 6channels or 12channels |
3 | Oil pressure sensor | 80MPa,Precision: 0.25%FS |
4 | Displacement transducer | Range:50mm Precision: 0.01 mm, |
5 | Curve | Q-S and S-lgt Curve |
6 | Wireless antenna | 3m, 485MHz, |
7 | Communication cable | 7cores, 30m |
8 | Testing distance | 30m with line; up to 1500m wireless communication (wild area.) |
9 | Power | 220V / 380V 50HZ |
Features:
1. Project testing and Data collecting is totally automatically: Auto
Loading, Auto Pressure compensation, Auto Data reading, Auto
Stability judgment and Data saving.
2. It adopts 10.4 inch colorful touchable LCD screen, 24 bit high AD resolution.
3. Clients can set difference grade, load number and reading number
optionally.
4. Console is powered by 12V DC instead of 220v. It is more
stability and anti-interference.
5. Real-time to show Experience information, Q-S curve, S-lgt
Curve, Sensor displacement.
6. It is with auto alarm function for safety protection, and it can
continually work automatically after power is suddenly off.
9. Sensor data can upload to console by wire or WIFI up to 1000m.
10. Wireless Channel upto 50. It supports multi sets (50sets) work
at same time for a work situ.
11.Displacement sensors can be installed with two methods, to pile or
to beam.