Completely compatible with plc s7 200 software,CPU and Extension Module,
It can perfectly replace each other,and plc step 7-MICRO/WIN programming software supported.
 
Type Number Available :
6ES7 232-0HB22-0XA0 EM232,  Analog output modules,2 output  
6ES7 232-0HD22-0XA0 EM232,  Analog output modules,4 output
 
--
ModelEM232 4 outputs ×12bits
Product Description4AO; 12 bits resolution voltage output;
11 bits resolution current output
Input Feature
From bus current consumption22mA
From L+ current consumption92mA
Power loss2.5W
Number of analog Input-
Signal input type-
Maximum input voltage-
Maximum input current-
Voltange input range: Unipolar-
Voltange input range: Bipolar-
current input range-
Resolution-
Bipolar,full-scale range-
Unipolar, full-scale range-
Analog to digital conversion time-
Number of analog Input4
Input voltage range-10~+10V
Input current range0~20mA
Load inpedance 
·for voltage outputsMin:5KΩ
·for current outputsMax:0.5KΩ
Resolution12 bits voltage output;
11 bits current output
Data word format 
·Displayable:voltage output-32,000~+32,000
·Displayable:current output0~32,000
Basic error±0.5% of full range
Dimensions(W x H x D)(mm)71.2×80×62
Order NumberUN 232-0HD22-0XA0
--

 

Hot Products

Box Material: ABS Box dimension : 100*100*75mm Cover: ABS plastic Cover or PC plastic clear cover ...
General fits for platform scales Screw terminal connectors for easy connection Signal trimming ...
100% Compatible Copy Design, Optoelectronic isolated No Driver needed, Instant Reading Supports S7...
Completely compatible with plc S7 200 software,CPU and Extension Module, It can perfectly replace ...
Completely compatible with plc S7 200 software,CPU and Extension Module, It can perfectly replace ...
Completely compatible with plc s7 200 software,CPU and Extension Module, It can perfectly replace ...