IEC60061-3 E26 lamp cap gauge, go gauge no go gauge, screw thread gauge


 

E26 and E26d Gauge list:

Model NumberGauge Name
7006-27D-3“GO” GAUGE FOR CAPS E26, E26/50x39, E26/51x39 & E26d
7006-29L-4“NOT GO” GAUGE FOR CAPS E26, E26/50x39, E26/51x39 & E26d
7006-29-3GAUGE FOR TESTING CONTACT-MAKING OF LAMPS FITTED WITH CAPS
7006-29A-2GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT E26d
7006-29B-2GAUGE WITH REFERENCE DIAMETER OF 23 mm FOR CAPS E26d
7006-29C-2GAUGE WITH REFERENCE DIAMETER OF 13,2 mm FOR CAPS E26d
7006-29D-1GUAGE WITH REFERENCE DIAMETER OF 10.4 mm FOR E26d CAPS ON FINISHED LAMPS

 

Confirms:
IEC60061-3

 

Purpose and Testing:
1. 7006-27D-3

“GO” GAUGE FOR CAPS E26, E26/50x39, E26/51x39 & E26d
PURPOSE:

To check the maximum dimensions of the screw thread and dimension T1min of E26, E26/50x39, E26/51x39 or E26d caps on finished lamps. 
TESTING:

When the cap on a finished lamp has been screwed into the gauge as far as it will go, the central contact shall touch surface X. When the lamp is removed from the gauge, at least two full turns shall be required to disengage the threads.
 
2. 7006-29L-4

“NOT GO” GAUGE FOR CAPS
E26, E26/50x39, E26/51x39 & E26d
PURPOSE:

To check the minimum outside (major) diameter of the screw thread, dimension d, of E26, E26/50x39, E26/51x39 orE26d caps on finished lamps.
TESTING:

When the gauge is placed over the thread of the cap on a finished lamp, held cap uppermost, the central contact shall not project beyond surface X. Only the weight of the gauge itself shall be used in the test.
 
3. 7006-29-3

GAUGE FOR TESTING CONTACT-MAKING OF LAMPS FITTED WITH CAPS
PURPOSE:

To check lamp dimensions for contact-making in E26, E26/50x39, E26/51x39 or E26d lampholders.
TESTING:

The shape of the lamp with regard to the fit in the lampholder is assumed to be correct, if the lamp can be pushed into the gauge until plane W reaches plane V or projects beyond it. For E26/24 capped lamps, when surfaces V and W are coincident, the top of the cap including any solder or conductive material, shall not extend above surface X.
 
4. 7006-29A-2

GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT E26d
PURPOSE:

To check protection against accidental contact of caps E26d on finished lamps.
TESTING:

When the lamp has been pushed into the gauge as far as it will go with the side solder of the cap located in the recess provided, surface W of the plunger shall not project beyond surface V.
 
5. 7006-29B-2

GAUGE WITH REFERENCE DIAMETER OF 23 mm FOR CAPS E26d
PURPOSE:

To check dimensions S min., S max., S1min. and S1max. of caps E26d.
TESTING:

When the cap (or lamp) has been pushed into the gauge as far as it will go, surface W of the plunger shall project beyond surface Y, but for unmounted caps, shall not project beyond surface X.
For caps on finished lamps, surface W shall not project beyond surface V.
  
6. 7006-29C-2

GAUGE WITH REFERENCE DIAMETER OF 13,2 mm FOR CAPS E26d
PURPOSE:

To check dimensions C max. and C1 max. of caps E26d.
TESTING:

When the unmounted cap has been pushed into the gauge as far as it will go, surface W of the plunger shall not project beyond surface X. For caps on finished lamps, surface W shall not project beyond surface V. In this instance, the cap shall be so positioned that the solder on the intermediate contact is located in the recess provided in the gauge.
 
7. 7006-29D-1
GUAGE WITH REFERENCE DIAMETER OF 10.4 mm FOR E26d CAPS ON FINISHED LAMPS
PURPOSE:

To check dimensions C1 min, andT1 min,show on sheet 7004-29 and the maximum dimensions of the cap thread. 
TESTING:

When the lamp has been screwed into the gauge as far as it will go, the surface “W” shall be co-planar with or project beyond surface “V”. After this test, at least two full turns of the lamp shall be required to disengage it from the gauge.
 
-------------------------------------------------------------------------------------------------------------------------------------
7006-27D-3 “GO” GAUGE FOR CAPS E26, E26/50x39, E26/51x39 & E26d
7006-29L-4 “NOT GO” GAUGE FOR CAPS E26, E26/50x39, E26/51x39 & E26d
7006-29-3 GAUGE FOR TESTING CONTACT-MAKING OF LAMPS FITTED WITH CAPS
7006-29A-2 GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT E26d
7006-29B-2 GAUGE WITH REFERENCE DIAMETER OF 23 mm FOR CAPS E26d
7006-29C-2 GAUGE WITH REFERENCE DIAMETER OF 13,2 mm FOR CAPS E26d
7006-29D-1 GUAGE WITH REFERENCE DIAMETER OF 10.4 mm FOR E26d CAPS ON FINISHED LAMPS
 

Hot Products

DIN-VDE0620 Germany Standard Plug Tester Outlets Gauges Lehre 6 – Lehre für den Stiftdurchmesser ...
BS1363 Plug Socket Tester BS546 Plug And Socket Measuring Gauges Specification: Product Model ...
UL498 Plug And Socket Measuring Gauge For Retention Of Blades Test Gauge list: NO. Product Name ...
VDE0620 Plug Socket Tester Germany Plug And Socket Measuring Gauge Gauge list: Figure number Project ...
IEC60061-3 E26 lamp cap gauge, go gauge no go gauge, screw thread gauge E26 and E26d Gauge list: ...
Gauge For Lampholders E40 E14 High Pressure Gauge For Lampholders List: 7006-25-7 “GO” GAUGE FOR ...