M6 Terminal 12v 150ah Solar Gel Battery In Wind Power System
 
Application of 12v 150ah Solar Gel Battery

 

Solar/Wind Power System
Uninterruptible Power Supplies (UPS)
Electric Power Systems (EPS)
Emergency Backup Power Supplies
Communication Power Supplies
DC Power Supplies
Auto Control System

 
Product Structure and Working Principle

 

Positive plate : Thick high Sn low Ca grid minimize corrosion and prolong life.

 

Negative plate : Balanced Pb-Ca grid for improved recombination efficiency.

 

Separator : Advanced AGM separator for ultra low float current.


Electrolyte : Dilute high purity sulphuric acid with nano gel.


Battery container and cover : ABS

 
Specification of 12v 150ah Solar Gel Battery

 

TypeGel Deep Cycle Battery
Nominal Voltage12V
Rated Capacity65Ah(10 Hr,10.8V,25℃)

Approx Dimensions(mm)
(Length×Width×Height)

L350mm x W166mm x H179mm
Cycle life≥3years
Approx Weight(kg)21kg
Applicable Temperature-40℃~60℃
Optimum Temperature20℃~25℃
Self-dischargeSelf-discharge rate<0.1% per day ( 20℃ )
Materials for Battery Containers and CoversABS
Screw Hole Size (mm)M6

 
Constant Currant Discharge Ratings-amperes at 25°C

 

F.V/Time5min10min15min30min1h2h3h4h5h8h10h20h
1.6V19514411973.243.925.518.414.712.28.356.893.71
1.67V17413311269.942.825.118.214.512.18.246.813.63
1.7V15512010667.341.824.718.014.312.08.146.723.54
1.75V13511298.265.040.924.317.714.211.88.036.633.48
1.80V11910291.662.139.623.817.413.911.57.846.503.41
1.85V10291.683.558.637.922.916.813.511.37.676.333.33


Constant Power Discharge Ratings-watts at 25°C

 

F.V/Time5min10min15min30min1h2h3h4h5h8h10h20h
1.6V34325921713581.947.934.827.823.316.113.37.20
1.65V31024120613080.247.434.627.723.216.013.27.09
1.70V28022119612678.947.134.427.623.115.913.16.99
1.75V24720818412377.946.734.227.523.015.813.06.89
1.80V22119117311876.046.133.827.122.615.512.96.81
1.85V19317415911373.544.733.026.522.315.312.76.70

 

Application Fields
 
Solar Power System, Wind Energy Storage System, UPS systems, switchgear, CATV and telecommunication systems applications, electric wheelchairs field, medical equipment field, washing machines field and so on.
 
Advantages
 
1. Long Life
 
VRLA gel type battery uses high-tin alloy positive grids and thick plates to reduce the utilization of active material. It has special additives. Its 40% DOD cycle life can reach over 3000 times as per the requirement of IEC 60896-22-2004.
 
2. Super Overdischarge Tolerance
 
After 5 times of over-discharges which cause the short circuit, battery capacity restoration can reach more than 95%.
 
3. High Cycling Ability
 
Special gel electrolyte additives, curing process at high temperature and high humidity are employed to delay the softening of active materiaI, therefore the deep cycle endurance is improved efficaciously, especially the anti-passivation (anti barrier layer) capability of positive plates during reaction when batteries are used for small load and small current discharge.
 
4. Excellent High-current Performance
 
Tighten assembly is designed to reduce distance of battery plates, to improvethe high current discharge performance.
 
5. Safety
 
The rubber 0-ring with strong corrosion resistance and the special adhesive are adopted to seal the terminals of the batteries, ensuring no acid leakage from the roots of terminals, and safe and reliabIe operation.
 
6. Maintenance Free
 
Since the design is of low liquid type, the gases generated inside the system is recombined into water; there is no need to add water or acid.
 
7. Various Installation Types
 
The special AGM separator can absorb the electrolyte thus there is no free acid inside the battery, therefore both verticaI and horizontaI positions are allowed when the batteries are to be mounted.

Hot Products

VRLA Rechargeable Valve Regulated Lead Acid Battery 12V 200AH Applications of Valve Regulated Lead ...
12 Volt 120AH Valve Regulated Sealed Lead Acid Battery SPC Exchange Valve Regulated Sealed Lead Acid ...
12V 200AH Valve Regulated Lead Acid Battery For Financial Center 12V 200AH Valve Regulated Lead Acid ...
Sealed Vrla Valve Regulated Lead Acid Battery 12V 200AH Deep Cycle​ Applications of Vrla Valve ...
12 Volt 24ah Vrla Lead Acid Battery Rechargeable Copper Terminal Vrla Lead Acid Battery features ...
12V 40AH Valve Regulated Lead Acid Battery In UPS Systems Power Station Valve Regulated Lead Acid ...