XLPE Insulated Medium Voltage Power Cables Multi Wire Bare Copper Conductor

 

Technical data

  • XLPE-insulated power cables to

DIN VDE 0276 part 620, HD 620 S2

and IEC 60502

  • Temperature range:during installation up to -5°C
  • Operating temperature : max. +90°C
  • Short circuit temperature:+250°C (short circuit duration max. 5 s)
  • Nominal voltages U0/U 6/10 kV, 12/20 kV, 18/30 kV
  • Operating voltages:for 6/10 kV = max. 12 kV for 12/20 kV = max. 24 kV for 18/30 kV = max. 36 kV
  • Test voltages:for 6/10 kV = 15 kV for 12/20 kV = 30 kV for 18/30 kV = 45 kV
  • Minimum bending radius:15x cable Ø
  • Power ratings table:see Technical Informations

 

Cable structure

  • Bare copper-conductor, to

DIN VDE 0295 cl.2, multi-wire, BS 6360 cl.2, IEC 60228 cl.2

  • Inner semi-conducting coating
  • Core insulation of cross-linked polyethylene (XLPE), compound type DIX8 to HD 620 S2
  • Outer conductive layer extruded and welded with core insulation

  • Conductive taping

  • Screen: Braiding of copper wires with one or two tape(s) applied helically
  • Wrapping
  • Outer sheath of PVC
  • compound type DMV6 to HD 620 S2
  • Sheath colour red

 

Properties

  • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers

Tests

  • self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)Installation notes
  • To guarantee an optimum on operating reliability the extruded semi-conductive layer is spliced with the insulation for long duration. For this reason we recommend a peeling tool for installation.

Note

rm = round conductor, multi-wire Further dimensions available on request.

AWG sizes are approximate equivalent values. The actual cross-section is in mm².

 

Application

Suitable for installation mostly for power supply stations, in indoors and in cable ducts,outdoor with protected laying, underground and in water as well as for installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristic, this can also be laid easily in difficult line guideways. The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures a construction free of partial discharges with high operational reliability.

Part no.No.cores x OperationNominalInsulationSheathOuter ØCop.WeightAWG-No.
 cross-sec. voltagevoltagethicknessthicknessmin. - max.weightapp. kg / km 
 mm² max.kVmmNominalmmkg / km  
      value    
      mm    
324001 x 35rm / 16126 / 103,42,523,0 - 28,0518,0905,02
324011 x 50rm / 16126 / 103,42,524,0 - 29,0662,01080,01
324021 x 70rm / 16126 / 103,42,526,0 - 31,0854,01310,02/0
324031 x 95rm / 16126 / 103,42,526,0 - 32,01094,01580,03/0
324041 x 120rm / 16126 / 103,42,528,0 - 34,01334,01860,04/0
324051 x 150rm / 16126 / 103,42,529,0 - 35,01622,02040,0300 kcmil
324061 x 150rm / 25126 / 103,42,529,0 - 35,01723,02210,0300 kcmil
324071 x 185rm / 16126 / 103,42,531,0 - 37,01958,02450,0350 kcmil
324081 x 185rm / 25126 / 103,42,531,0 - 37,02059,02580,0350 kcmil
324091 x 240rm / 16126 / 103,42,533,0 - 39,02486,03000,0500 kcmil
324101 x 240rm / 25126 / 103,42,533,0 - 39,02587,03130,0500 kcmil
324111 x 300rm / 25126 / 103,42,536,0 - 41,03163,03780,0600 kcmil
324121 x 400rm / 35126 / 103,42,540,0 - 45,04234,04670,0750 kcmil
324131 x 500rm / 35126 / 103,42,543,0 - 48,05194,05750,01000 kcmil
330991 x 630rm / 35126 / 103,42,544,0 - 49,06442,07180,01250 kcmil
324141 x 35rm / 162412 / 205,52,527,0 - 32,0518,01110,02
324151 x 50rm / 162412 / 205,52,528,0 - 33,0662,01250,01
324161 x 70rm / 162412 / 205,52,530,0 - 35,0854,01510,02/0
324171 x 95rm / 162412 / 205,52,531,0 - 36,01094,01780,03/0
324181 x 120rm / 162412 / 205,52,532,0 - 38,01334,02070,04/0
324191 x 150rm / 162412 / 205,52,533,0 - 39,01622,02310,0300 kcmil
324201 x 150rm / 252412 / 205,52,533,0 - 39,01723,02420,0300 kcmil
324211 x 185rm / 162412 / 205,52,535,0 - 41,01958,02650,0350 kcmil
324221 x 185rm / 252412 / 205,52,535,0 - 41,02059,02810,0350 kcmil
324231 x 240rm / 162412 / 205,52,538,0 - 44,02486,03260,0500 kcmil
324241 x 240rm / 252412 / 205,52,538,0 - 44,02587,03360,0500 kcmil
324251 x 300rm / 252412 / 205,52,540,0 - 46,03163,04020,0600 kcmil
324261 x 400rm / 352412 / 205,52,543,0 - 49,04234,04930,0750 kcmil
324271 x 500rm / 352412 / 205,52,546,0 - 52,05194,06050,01000 kcmil
330961 x 630rm / 352412 / 205,52,547,0 - 53,06442,07510,01250 kcmil

 

Part no.No.cores x OperationNominalInsulationSheathOuter ØCop.WeightAWG-No.
 cross-sec. voltagevoltagethicknessthicknessmin. - max.weightapp. kg / km 
 mm² max.kVmmNominalmmkg / km  
      value    
      mm    
324281 x 50rm / 163618 / 3082,532,0 - 38,0662,01480,01
324291 x 70rm / 163618 / 3082,534,0 - 40,0854,01730,02/0
324301 x 95rm / 163618 / 3082,535,0 - 41,01094,02060,03/0
324311 x 120rm / 163618 / 3082,537,0 - 43,01334,02330,04/0
324321 x 150rm / 253618 / 3082,538,0 - 44,01723,02720,0300 kcmil
324331 x 185rm / 253618 / 3082,540,0 - 46,02059,03100,0350 kcmil
324341 x 240rm / 253618 / 3082,542,0 - 48,02587,03730,0500 kcmil
324351 x 300rm / 253618 / 3082,545,0 - 51,03163,04000,0600 kcmil
324361 x 400rm / 353618 / 3082,548,0 - 54,04234,05330,0750 kcmil
324371 x 500rm / 353618 / 3082,551,0 - 57,05194,06480,01000 kcmil
330981 x 630rm / 353618 / 3082,552,0 - 59,06442,07970,01250 kcmil

 

Hot Products

N2XSEY XLPE PVC Medium Voltage Power Cables Three Core For Power Transmission Applications Overview ...
Industrial UV Resistant Xlpe Armoured Cable Single Core Copper Conductor Applications Overview ...
Multi Core Aluminium Medium Voltage Power Cables NA2XS2Y / NA2XSF2Y / NA2XSFL2Y Applications ...
6kV / 10kV Medium Voltage 2 Phase Cable Xlpe Insulated Wire Fire Resistant Since about 1970 the ...
XLPE Insulated Medium Voltage Power Cables Multi Wire Bare Copper Conductor Technical data XLPE...
Medium Voltage Cable, MV Cables, Power Cables Medium Voltage cables, or MV cables, is a category ...