Home Companies Guangdong Shengyu Cable Industry Co., Ltd.

BS 7211 624 B Twin And Earth LSZH Cable Cross Linked Polyethylene Wire

Guangdong Shengyu Cable Industry Co., Ltd.
Active Member

Contact Us

[China] country

Address: No. 23, Dongzhi Rd, Guangzhou Development District, Guangzhou, Guangdong, China.

Contact name:Nicole Weng

Inquir Now

Guangdong Shengyu Cable Industry Co., Ltd.

BS 7211 624 B Twin And Earth LSZH Cable Cross Linked Polyethylene Wire

Country/Region china
City & Province guangzhou guangdong
Categories Electrical Wires
InquireNow

Product Details

BS 7211 624 B Twin And Earth LSZH Cable Cross Linked Polyethylene Wire

 

APPLICATION

Installation in walls, on boards and in channels or embedded in plaster. For installations where fire, smoke emissions and toxic fumes create a potential risk to life and equipment.

 

 

CONSTRUCTION

Conductor

1mm2 to 2.5mm2: Class 1 solid conductor according to BS EN 60228 (previously BS 6360)

4mm2 to 10mm2: Class 2 stranded conductor according to BS EN 60228 (previously BS 6360)

 

 

Circuit Protection Conductor (Earth)

1mm² to 2.5mm²: Class 1 solid copper conductor 4mm² to 16mm²: Class 2 stranded copper conductor

 

 

Insulation

XLPE (Cross-Linked Polyethylene) Type GP8

 

 

Sheath

LSZH (Low Smoke Zero Halogen) Type LTS2

 

 

CABLE STANDARDS

BS 7211, IEC 60754-1, IEC 60754-2, IEC 61034,

BS EN/IEC 60332-1-2

 

 

The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Sunwin Cables laboratory.

Cable performance in respect of conductor resistance, construction quality (workmanship),dimensional consistency, and other parameters are verified to published standardsand approved product drawings. Conformance to RoHS (Restriction of the use ofHazardous Substances) is determined and confirmed.

 

 

CHARACTERISTICS

Voltage Rating (Uo/U) 300/500V

 

 

Temperature Rating

+5°C to +70°C

 

 

Minimum Bending Radius

3 x overall diameter

 

 

Core Identification

Brown Blue

 

 

Sheath Colour

White

 

Find this product online: sunwincable.com | Cables & Accessories Guangdong Shengyu Cable Industry Co., Ltd. | Technical specification |2/2

 

 

DIMENSIONS

 

Sunwin PART NO.NO. OF CORES

NOMINAL CROSS SECTIONAL AREA

mm2

CONDUCTOR CLASS

CROSS SECTIONAL AREA OF CIRCUIT PROTECTIVE CONDUCTOR

mm

NOMINAL THICKNESS

OF INSULATION

mm

NOMINAL THICKNESS OF SHEATH

mm

NOMINAL OVERALL DIMENSIONS

mm

A9B02010WH21110.60.94.8 x 8.4
A9B02015WH21.5110.70.94.8 x 9.2
A9B02025WH22.511.50.815.7 x 10.5
A9B02040WH2421.50.816.1 x 11.7
A9B02060WH2622.50.81.16.9 x 13.6
A9B0210WH2102411.28.1 x 16.2
A9B03010WH31110.60.94.7 x 11
A9B03015WH31.5110.70.94.9 x 11.8
A9B03025WH32.5110.815.6 x 13.3
A9B03040WH3421.50.816.2 x 15.7

 

CONDUCTORS

Class 1 Copper Conductor for Single and Multi-Core Cables

 

NOMINAL CROSS SECTIONAL AREA

mm²

MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC

Plain Wires

ohms/km

118.1
1.512.1
2.57.41
44.61
63.08
101.83

 

 

ELECTRICAL CHARACTERISTICS

Current Carrying Capacity and Voltage Drop

 

NOMINAL CROSS SECTIONAL AREA

mm²

REFERENCE METHOD A* (IN CONDUIT IN WALL)

Amps

REFERENCE METHOD C* (CLIPPED DIRECT)

Amps

VOLTAGE DROP

mv/A/m

111.51644
1.514.52029
2.5202718
4263711
632477.3
1044644.4
1657852.8

The above table is in accordance with 4D5 of the 17th Edition of IEE Wiring Regulations. Note

A* For full installation method refer to Table 4A2 Installation Method 2 but for flat twin and earth cable of the 17th Edition of IEE Wiring Regulations. C* For full installation method refer to Table 4A2 Installation Method 20 but for flat twin and earth cable of the 17th Edition of IEE Wiring Regulations.

 

 

The information contained within this datasheet is for guidance only and is subject to change without notice or liability. All the information is provided in good faith and is believed to be correct at the time of publication. When selecting cable accessories, please note that actual cable dimensions may vary due to manufacturing tolerances.

Hot Products

6491X / H07V-R / H07V-U / BS EN 50525-2-31 Cable APPLICATION 6491X Cable H07V-R/H07V-U is suitable ...
309-Y / H05V2V2-F BS EN 50525-2-11 Flexible Cable APPLICATION For internal wiring or supply cords to ...
Applications Overview The 6491X cable is a single core low voltage insulated cable manufactured in ...
Flexible Copper Insulated Electrical Wire H05Z K H07Z K BS EN 50525-3-41 Cable APPLICATION LSZH ...
BS 7211 624 B Twin And Earth LSZH Cable Cross Linked Polyethylene Wire APPLICATION Installation in ...
PVC Type 6 Insulated Electrical Wire Domestic Wiring Cable BS 6004 624 Y APPLICATION Domestic wiring ...