1. Product introduction:

1.1 Product name and model:17.5kV Pad mounted primary metering cabinet PMY9-17.5, JLSZXW9-17.5 combined transformer

1.2 Product overview:

The metering cabinet is for outdoor cabinet type one-piece three-phase primary metering unit , inside has assembled a combination of three independent voltage transformer and current transformer, voltage transformers are made up of three-phase Y-Y star connection, current transformers can be 2pcs or 3pcs optional configuration, cabinet adopts zinc steel, stainless steel or aluminum alloy etc, cabinet surface spraying protection layer resistant to acid and alkali corrosion , prevent the UV irradiation, suitable for outdoor underground cable connected to the public power system. The metering cabinet has installed complete measuring meter box or interval, instrument transformers’ secondary lead all converge in meter box, equipped with test terminal blocks and electric meter installation space, can be configured as required when using electric meter or the user configuration of watt-hour meter can access, suitable for high voltage equipment in urban power distribution network line 17.5 kV and below for electric energy metering, current and voltage measurements.

1.3 Basic parameters:

 

No.

item

units

specification

  1.  

Highest voltage for
equipment Um (r.m.s.)

 

kV

17.5

  1.  

rated frequency (fR)

Hz

50, 60 or 50/60

  1.  

Rated lightning impulse
withstand voltage (peak)

 

kV

95 ,110

  1.  

Rated power-frequency
withstand voltage on primary

 

kV

38

  1.  

Rated power-frequency
withstand voltage on secondary

 

kV

3

  1.  

Number of CTs and VTs

pcs

3VT+3CT or 2CT+3VT

  1.  

Standard

/

IEC 61869-1:2007, IEC 61869-2:2012 IEC 61869-3:2011,IEC 61869-4:2013

 
2. Function and Application of the product:
Pad mounted Primary Metering Cabient meets the latest applicable industry standards and local and/or national electrical regulatory requirements. Used for energy metering management and automatic distribution network management system of three-phase underground cable urban distribution network, the primary side measurement is more accurate, and the electric energy loss of the line can be effectively measured to reduce the loss.
 
3. Main Features of the product:
1 The metering cabinet adopts the overall housing-shaped box design and is divided into three internal compartments, including medium-voltage cable connection room, medium-voltage instrument transformer room and metering meter box room. The compact and beautiful housing design does not affect the greening and landscape, and the outdoor floor installation is convenient and quick;
2 The metering unit shall assemble the instrument transformer and the meter box as a whole, preset the alarm signal of the door switch sensor, the lock seal and the ingenious door opening and closing linkage structure. Only after the medium-voltage cable room is opened, then anti-electricity-stealing design of meter box room can be opened.
3 The cabinet body is made of corrosion-resistant stainless steel or low carbon steel of the same performance. It is designed to be weather-proof, and the surface is coated with anticorrosive paint powder layer,acid and alkali resistance, UV resistance.
4 The internal MV combined instrument transformer is encapsulated and poured with epoxy resin solid, the surface is fully screened and touchable, and can be closely fitted with the external box. The compact size is only half that of the air insulation metering box, free of oil and gas and free of maintenance, meeting the requirements of safe operation and environmental protection;
5 The primary connection adopts separable sealing connection. The primary connection bushing have two connection types( 200A bushing well insert+200A connector and 600A interface bushing+600A connector) according to standard IEEE STD 386.
 
4. Product technical parameters:
Current transformer specifications

 

No

Item

Parameters

  1.  

Rated primary current

5A up to 600A

  1.  

Rated secondary current

5A or 1A

  1.  

Rated Continuous Thermal Current

120%,125%,150%,200% etc.

  1.  

Rated Short time current (Ith) (thermal 1 second)

80xIpr,100xIpr

  1.  

Rated Dynamic Current (Idyn)

2.5xIth

  1.  

Rated Output(VA)

12.5,15,20

  1.  

Accuracy Class

0.2S,0.2,0.5S,0.5,1 Metering

  1.  

Instrument Security Factor (FS)

5,10,20

  1.  

Applicable Standard

IEC: 61869-1&2

Voltage transformer specifications

 

No

Item

Parameters

  1.  

Rated primary voltage(V)

13200/√3,13800/√3,7200,8400

  1.  

Rated secondary voltage(V)

100/√3,110/√3,110,120,115

  1.  

Rated Voltage Factor

1.2/Continuous

1.5/30s,1.9/30s,1.9/8h

  1.  

Standard connection

Y-Y(star connection)

  1.  

Rated Output(VA)

15,20,25,30,50,75

  1.  

Accuracy Class

0.2,0.5,1,3 Metering

  1.  

Thermal burden(VA)

500

  1.  

Applicable Standard

IEC: 61869-1&3

Notes: If the parameters required by the user are beyond the scope of the above table, can be determined after negotiation with our company.
 
5. Product dimensions and wiring schematic diagram:
Cable connector connection to combined transformer (200A)
Cable connector connection to combined transformer (600A)
Wiring diagram
 
6. Special Instructions
Can be designed and manufactured according to the special requirements of customers.

Hot Products

1. Product introduction: 1.1 Product type name and model: Install the metering box OMY-12, JLSZYW-12 ...
1.Product Introduction 1.1 Product Type Model: 17.5kV MV Overhead Pole Mounted Metal Casing Dry type ...
I. Brief 1.1 Name and Model: 12kV pad mounted metering unit PMY6-12, combined transformer JLSZXW6-12 ...
I. Brief 1.1 Name and Model: 12kV pad mounted metering unit PMY5-12, combined transformer JLSZXW5-12 ...
1. Product introduction: 1.1 Product name and model:17.5kV Pad mounted primary metering cabinet PMY9...
1. Product introduction: 1.1 Product name and model:24kV Pad mounted primary metering cabinet PMY9...