Shenzhen Wisdomlong Technology CO.,LTD |
Verified Suppliers
|
|
Industrial Servo Motor Yaskawa54.7a Amp 200v-ac 7.5kw 48nm Servo Motor SGMGV-75A3A6C
Quick Details
Brand Name:Yaskawa
Model Number:SGMAH-03DAA61D
Power : 7500W
Voltage: 200V
Current: 54.7A
N.m: 48
Ins : F
Place of Origin:Japan
Efficiency:IE 1
OTHER SUPERIOR PRODUCTS
SGMGH-44A2A-YR14 |
SGMGH-44ACA2C |
SGMGH-44ACA61 |
SGMGH-55A2A-YR14 |
SGMGH-55A2B2C |
SGMGH-75ACA6 |
SGMGH-75ACA61 |
SGMGH-75PCA2C |
SGMG-SGMGH |
SGMGV-05ADA21 |
SGMGV-09ADA61 |
SGMGV-09ADC21 |
SGMGV-09ADC61 |
SGMGV-13ADA21 |
SGMGV-13ADA61 |
SGMGV-13ADA6C |
SGMGV-1AADA61 |
SGMGV-20ADA21 |
SGMGV-20ADC61 |
SGMGV-30ADA21 |
SGMGV-30ADB6C |
SGMGV-30ADC61 |
SGMGV-44ADA21 |
SGMGV-44ADA2C |
SGMJ-01AP |
SGMJV-01A3A21 |
SGMJV-01A3A2C |
SGMJV-01AAA61 |
SGMJV-01AD |
SGMJV-01ADA21 |
SGMJV-01ADA2C |
SGMJV-01ADA61 |
SGMJV-01ADAB1 |
SGMJV-01ADAHC2C |
SGMJV-01ADE6S |
SGMJV-02A3A21 |
SGMJV-02A3A-SU11 |
SGMJV-02AAA21 |
SGMJV-02ADA21 |
• Do not perform a withstand voltage test on any part of the unit. This equipment uses sensitive devices and may be damaged by high voltage.
• The Drive is not suitable for circuits capable of delivering more than the specified RMS symmetrical amperes. Install adequate branch short circuit protection per applicable codes. Refer to the specification. Failure to do so may result in equipment damage and/or personal injury.
• Do not connect unapproved LC or RC interference suppression filters, capacitors, or overvoltage protection devices to the output of the Drive. These devices may generate peak currents that exceed Drive specifications.
• To avoid unnecessary fault displays caused by contactors or output switches placed between Drive and motor, auxiliary contacts must be properly integrated into the control logic circuit.
• YASKAWA is not responsible for any modification of the product made by the user; doing so will void the warranty. This product must not be modified.
• Verify that the rated voltage of the Drive matches the voltage of the incoming power supply before applying power.
• To meet CE directives, proper line filters and proper installation are required.
• Some drawings in this manual may be shown with protective covers or shields removed, to describe details. These must be replaced before operation.
• Observe electrostatic discharge procedures when handling circuit cards to prevent ESD damage.
• The equipment may start unexpectedly upon application of power. Clear all personnel from the drive, motor, and machine area before applying power. Secure covers, couplings, shaft keys, and machine loads before energizing the Drive. •
Please do not connect or operate any equipment with visible damage or missing parts. The operating company is responsible for any injuries or equipment damage resulting from failure to heed the warnings in this manual.
Caution
• Do not store or install the product in the following places.
• Locations subject to direct sunlight.
• Locations subject to temperatures outside the range specified in
the storage or installation temperature conditions.
• Locations subject to humidity outside the range specified in the
storage or installation humidity conditions.
• Locations subject to condensation as the result of extreme
changes in temperature.
• Locations subject to corrosive or flammable gases.
• Locations subject to dust, salts, or iron dust.
• Locations subject to exposure to water, oil, or chemicals.
• Locations subject to shock or vibration.
Failure to observe this caution may result in fire, electric shock,
or damage to the product.
• Do not hold the product by the cables or motor shaft while
transporting it.
Failure to observe this caution may result in injury or
malfunction.
• Do not place any load exceeding the limit specified on the
packing box.
Failure to observe this caution may result in injury or
malfunction.