CAUTION
• Conduct trial operation on the servomotor alone with the motor shaft disconnected from machine to avoid any unexpected accidents. Failure to observe this caution may result in injury.
• Before starting operation with a machine connected, change the settings to match the parameters of the machine. Starting operation without matching the proper settings may cause the machine to run out of control or malfunction.
• Forward run prohibited (P-OT) and reverse run prohibited (N-OT) signals are not effective during zero point search mode using parameter Fn003.
• When using the servomotor for a vertical axis, install the safety devices to prevent workpieces to fall off due to occurrence of alarm or overtravel. Set the servomotor so that it will stop in the zero clamp state at occurrence of overtravel. Failure to observe this caution may cause workpieces to fall off due to overtravel.
• When not using the normal autotuning, set to the correct moment of inertia ratio. Setting to an incorrect moment of inertia ratio may cause vibration.
• Do not touch the SERVOPACK heatsinks, regenerative resistor, or servomotor while power is ON or soon after the power is turned OFF. Failure to observe this caution may result in burns due to high temperatures.
• Do not make any extreme adjustments or setting changes of parameters. Failure to observe this caution may result in injury due to unstable operation.
• When an alarm occurs, remove the cause, reset the alarm after confirming safety, and then resume operation. Failure to observe this caution may result in injury.
• Do not use the servo brake of the servomotor for ordinary
braking. Failure to observe this caution may result in malfunction
Industrial Vertical Submersible Sewage Pump , Electrical Wastewater
Submersible Pump For Septic Tank Application: Wastewater lift
station; Municipal wastewater treatment plant; Building wastewater
treatment system; Animal & poultry farm wastewater treatment
system; Hospital, school, community etc. Wastewater treatment
system; Food, paper, mining, textile, leather, chemical industry
etc. wastewater treatment system. Water purification system.
Features: NON-CLOG IMPELLER Well statically & dynamically
balanced Non-Clog impeller is designed to allow sizable spherical
solids to pass the plow passage easily without clogging.It adopts
rigorous technics so that vibration and noise can be farthest
reduced. LEAKAGE DETECTOR Built-in leakage detector in the oil
chamber can dectet leakage from the damage of the mechanical seal.
(The power lower than 15KW is optional,not lower than 15KW is
standard accessories.)Built-in leakage detector in the wiring box
can check if a leak in it,The leakage detector offers pump an
automatic protection. (Not stamdard accessories, the power not
lower than 18.5KW is optional) HEAT-DETECTOR Built-in heat
protector in motor, it secures the protection of motor against
burning out. (The power lower than 15KW is optional,not lower than
15KW is standard accessories.) overload & overheating to
Built-in heat protector in bearing, when the bearing is abnormal
and the temp- erature rises to disconneting temperature, the
protector automatically cat off power supply to protect the
bearing.(options) COOLING JACKET (OPTIONAL) Pumps make use of inner
pressure of pump cauvty to make liquid contiwue entering to space
between cooling house and motor outer, to take away the heat the
motor produces. ( The power not lower than 18.5KW is optional)
Points for attention before starting equipment: # # Check the
insulation condition of the stator winding with a 0-500V meter
before starting the water pumps. # Check whether the power and the
voltage frequency used are in line with those listed on the label.
# Don't connect the electric wire of the water pump with the power
source without any protective device (which may lead to the burning
of the motor due to open-phase and overload). Refer to the
connection method of the submersible pump. (refer to Page 9 for
details). # Before installation, check the rotation direction of
the motor, the correction rotation direction is that the motor
rotates counter-close seen from the suction direction of the
impeller. If the rotation direction is not right, the connection
positions of any two phases in three phases shall be shifted to get
it rotate in a correct direction. # Check whether the grounding
wire is earthed properly. # Check whether the operation of the
level controller is in normal so as not to affect the service life
of the submersible motor. # Close the gate valve of the outlet
pipeline and start the motor. Under the circumstance that the gate
valve of the outlet pipeline is shut, the pump cannot rotate over 3
minutes continuously. Monitor the motor current by switching on the
gate valve and control the current within the rated range, and
check whether the pressure of the pressure gauge and the operation
of the pump are in normality, and refer to the trouble shooting
sheet to remove in case of abnormality. # Operation without water
is prohibited. # Submerging cable sockets of the motor into water
is prohibited. # Lifting and hanging the motor with the motor cable
is prohibited during the transport and installation processes.
Construction: - - - - No. Name Material GB JIS 1 Neck bolt 2Cr13
SUS420 2 Heat-Protector - - 3 Motor cover HT200 FC200 4-1 Bearing -
- 4-2 Bearing - - 5 Cooling house flange Q215A LSS330 6 Shaft 2Cr13
SUS420 7 Rotor - - 8 S