  1. Power : 850W
  2. Voltage:200V
  3. Rated Current : 7.1A

 

 

DESCRIPTION

  • AC Servo Motor
  • SGMAV Sigma-5
  • YASKAWA ELECTRIC

 

 

 

SEPCIFICATIONS

Brand NameYaskawa
Model Number Industrial Servo Motor Yaskawa 5.39N.m 200V AC Servo Motor SGMGH-09ACA61
Place of OriginJapan
Current7.1A
Voltage 200V
Speed 1500/min
Power850W
InsF
N.m5.39

 

 

 

 

* Are external motor disconnects required between the motor and the VFD? Service disconnects at motor loads are very often used for maintenance purposes. Normally, removing a load from a VFD while operating does not pose a problem for the VFD. On the other hand, introducing a load to a VFD by closing a motor disconnect while the VFD is operational can be fatal to the VFD.
 

When a motor is Started at full voltage, as would happen in this case, high currents are generated, usually about six times the full load amps of the motor current. The VFD would see these high currents as being well beyond its capabilities and would go into a protective trip or fail altogether. A simple solution for this condition is to interlock the VFD run permissive circuit with the service disconnects via an auxiliary contact at the service disconnect. When the disconnect is closed, a permissive run signal restarts the VFD at low voltage and frequency.
 

* Are there power factor correction capacitors being switched or existing on the intended motor loads? Switching of power factor capacitors usually generates power disturbances in the distribution system. Many VFDs can and will be affected by this. Isolation transformers or line reactors may be required for these applications.
 
 
 
 
 

Power factor correction at VFD-powered motor loads is not necessary as the VFD itself does this by using DC internally and then inverting it into an AC output to the motor. All VFD manufacturers warn against installing capacitors at the VFD output.
 

Variable Frequency Drive Technologies
Three basic types of variable frequency drives offer certain advantages as well as disadvantages
depending on your motor application. The new flux vector drive is also discussed.
 

While all variable frequency drives (VFDs) control the speed of an AC induction motor by varying the motor's supplied voltage and frequency of power, they all do not use the same designs in doing so. There are three major VFD designs commonly used today: pulse width modulation (PWM), current source inverter

 

 

 

 

Installing the Servomotor

 

Servomotor SGM and SGMP types can be installed either horizontally or vertically. However, if the Servomotor is installed incorrectly or in an inappropriate location, the service life will be shortened or unexpected problems will occur. To prevent this, always observe the installation instructions described below.

 

 

Before installation:

 

Anticorrosive paint is coated on the edge of the motor shaft. Clean off the anticorrosive paint           thoroughly using a cloth moistened with thinner.

 

                                        

 

NOTE

 

Avoid getting thinner on other parts of the Servomotor when cleaning the shaft.

 

 

Storage:

 

 

When the Servomotor is to be stored with the power cable disconnected, store it in the following temperature range:

 

                      Between −20°C and 60°C

 

 

Installation sites:

 

The Servomotor SGM and SGMP types are designed for indoor use.

 

Install Servomotor in an environment which meets the following conditions:

  1. Free from corrosive and explosive gases
  2. Well-ventilated and free from dust and moisture 
  3. Ambient temperature of 0 to 40°C
  4. Relative humidity of 20% to 80% (non-condensing)
  5. Inspection and cleaning can be performed easily

If the Servomotor is used in a location subject to water or oil mist, install a shield cover over the Servomotor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIMILAR PRODUCTS

SGMAV-04A3A6CSGMAV-04ADA21
SGMAV-04ADA2CSGMAV-04ADA61
SGMAV-04ADAH12CSGMAV-04ADAHB21
SGMAV-06A3A21SGMAV-06A3A61
SGMAV-06A3A6CSGMAV-06A3A6S
SGMAV-06ADA21SGMAV-06ADA2C
SGMAV-02A3A6SSGMAV-02ADA21
SGMAV-08A3A61SGMAV-02ADAHB21
SGMAV-08ADA21SGMAV-08A3A2C
SGMAV-08A3A21SGMAV-06ADAHB21

 

 

 

 

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG-Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X-Emerson VE-,KJ-
Honeywell TC-,TK-GE Modules IC -
Fanuc motor A0-Yokogawa transmitter EJA-
 
 

Contact person: Anna Bao
Cellphone: +0086-13534205279
E-mail: wisdomlongkeji@163.com
 
 

 

 

 

Hot Products

Industrial Yaskawa Electric SGMGH Series 850W AC SERVO MOTOR SGMGH-09ACA21 Specifications Manufactur...
MITSUBISHI 750W AC SERVO MOTOR HG-KR73BG1 HG-KR73BG5 3000r/min NEW Specifications for HG-KR73BG1 ...
QJ71AS92 Mitsubishi Universal model Redundant Power Supply Module Model: QJ71AS92 Master station. AS...
Mitsubishi Universal model Redundant Power Supply Module Q61LD Model: Q61LD Q61LD /> 1 channel. ...
Industrial Servo Motor Yaskawa 5.39N.m 200V AC Servo Motor SGMGH-09ACA61​ QUICK DETAILS Power : 850W ...
Q172LX Mitsubishi Universal model Redundant Power Supply Module Model: Q172LX. Number of Input ...